View larger
Images are for illustrative purposes only. Please refer to data sheet for details
2CCS573103R8024 ABB S403M-C2NP Miniature Circuit Breaker 4 Poles NPC 2A 10000 ~230/400V
2CCS573103R8024
10000
ABB
1 Pcs.
S403M-C2NP Miniature Circuit Breaker 4 Poles NPC 2A 10000 ~230/400V
SMISSLINE-I. Aut S403M-NP C 2 A
Miniature Circuit Breaker - S400NP - 4P - 2 A - C - (230 V) 10 kA
Automation > Miniature circuit breaker (MCB)
SMISSLINE
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
2CCS573103R8024 ABB S403M-C2NP Miniature Circuit Breaker provides automated circuit protection by interrupting excessive current loads and short circuits within electrical installations.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 92.73 %
- ABB Site Meeting Group Waste To Landfill Target: No non-hazardous waste is sent to a landfill
- Sustainable Material Content in Packaging (wt. %): Recycled Cardboard - 18.12 %
- Extended Product Lifetime: Product Durability
- End Of Life Disassembling Instructions: 9AKK108469A6908
- Environmental Product Declaration - EPD: 9AKK108469A5735
- Rated Operational Current (I e ): 2 A
- Rated Ultimate Short-Circuit Breaking Capacity (I cu ): (230 V) 25 kA
- Rated Short-Circuit Making Capacity (I cm ): (440 V AC) 30 kA
- Rated Service Short-Circuit Breaking Capacity (I cs ): (240 V AC) 15 kA
- Power Supply Connection: Arbitrary
- Contact Position Indication: Red ON / Green OFF
- Energy Limiting Class: 3
- Electrical Endurance: 10000 cycle
- Mechanical Endurance: 10000 cycle
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 92.73 % |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| Sustainable Material Content in Packaging (wt. %) | Recycled Cardboard - 18.12 % |
| Recycled Cardboard - 67.66 % | |
| Chemically Recycled Polymer - 0 % | |
| Extended Product Lifetime | Product Durability |
| End Of Life Disassembling Instructions | 9AKK108469A6908 |
| Environmental Product Declaration - EPD | 9AKK108469A5735 |
| Technical | |
| Rated Operational Current (Ie) | 2 A |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V) 25 kA |
| (400 V) 25 kA | |
| Rated Short-Circuit Making Capacity (Icm) | (440 V AC) 30 kA |
| (415 V AC) 52.2 kA | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (240 V AC) 15 kA |
| (415 V AC) 15 kA | |
| (440 V AC) 7.5 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 50 % |
| Power Supply Connection | Arbitrary |
| Contact Position Indication | Red ON / Green OFF |
| Energy Limiting Class | 3 |
| Electrical Endurance | 10000 cycle |
| Mechanical Endurance | 10000 cycle |
| Number of Protected Poles | 4 |
| Number of Poles | 4P |
| Tightening Torque | 2.8 N·m |
| Release Type | C |
| Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
| Actuator Marking | I / O |
| Recommended Screw Driver | Pozidriv 2 |
| Accessories Available | Yes |
| Connecting Capacity | Flexible 0.75 … 25 mm² |
| Rigid 0.75 … 35 mm² | |
| Terminal Type | Screw Terminals |
| Electrical | |
| Tripping Characteristic | C |
| Rated Operational Voltage | acc. to IEC 60898-1 415 V |
| Operational Voltage | Maximum (Incl. Tolerance) 440 V AC |
| Minimum 12 V AC | |
| Minimum 12 V DC | |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 440 V |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Input Voltage Type | AC |
| Rated Current (In) | 2 A |
| Rated Short-Circuit Capacity | (230 V) 10 kA |
| (400 V) 10 kA | |
| Frequency (f) | 50 ... 60 Hz |
| Rated Frequency (f) | 50 ... 60 Hz |
| Power Loss | 11.2 W |
| Overvoltage Category | III |
| Material Compliance | |
| RoHS Declaration | 9AKK107991A9634 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20210407 |
| REACH Declaration | 9AKK108467A9561 |
| REACH Information | True - contains substances > 0.1 mass percentage |
| REACH Date | 20230417 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Business |
| Environmental | |
| Ambient Air Temperature | Operation -25 … 60 °C |
| Reference Ambient Air Temperature | 30 °C |
| Degree of Protection | IP20 |
| Pollution Degree | 3 |
| Resistance to Vibrations | 1 mm 2 … 13.2 Hz |
| Environmental Information | 9AKK108467A9561 |
| Dimensions | |
| Width in Number of Modular Spacings | 4 |
| Product Net Width | 72 mm |
| Product Net Height | 91 mm |
| Product Net Depth / Length | 75 mm |
| Product Net Weight | 428 g |
| Built-In Depth (t2) | 75 mm |
| Dimension Diagram | 9AKK107492A6192 |
| Engineering | |
| EPLAN Data | 9AAC128475_EPLAN |
| Ordering | |
| Package Level 1 Units | carton 3 piece |
| Package Level 1 Gross Weight | 1355 g |
| E-Number (Norway) | 1623505 |
| E-Number (Switzerland) | 809172817 |
| Certificates and Declarations | |
| Declaration of Conformity - CE | 9AKK107991A9634 |
| Installation | |
| Instructions and Manuals | 2CCC451019M0109 |
| Mounting Position | Any |
| Popular Downloads | |
| Data Sheet, Technical Information | 9AKK107492A6192 |
| External Classifications and Standards | |
| ETIM 9 | EC000042 - Miniature circuit breaker (MCB) |
| ETIM 10 | EC000042 - Miniature circuit breaker (MCB) |
| eClass | V11.0 : 27141901 |
| Object Classification Code | FC |
| Standards | IEC/EN 60898-1 |
| IEC/EN 60947-2 | |