View larger
1SFA898217R7000 ABB Soft Starter 400V/315kW, 500V/400kW, 690V/560kW, 570A
1SFA898217R7000
898217
ABB
1 Pcs.
Automation > Soft starter
starters PSTX
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for high-power industrial applications, an ABB soft starter controls motor starting profiles to eliminate mechanical stress and reduce peak electrical demand. Heavy machinery installations utilize these robust controllers to safeguard drive trains and improve operational efficiency. This 1SFA898217R7000 unit handles demanding electrical loads. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85371091
- Data Sheet, Technical Information: 1SFC132012C0201
- Instructions and Manuals: 1SFC132428M0201
- Instructions and Manuals (Part 2): 1SFC132081M0201
- Instructions and Manuals (Part 3): 1SFC132060M0201
- CAD Dimensional Drawing: 2CDC001079B0201
- EPLAN Data: 9AAC184490_EPLAN
- Wiring Diagram: N/A
- Product Net Width: 361 mm
- Product Net Height: 493 mm
- Product Net Depth / Length: 282 mm
- Product Net Weight: 27 kg
- Rated Operational Voltage: 208 ... 690 V AC
- Rated Control Supply Voltage (U s ): 100 ... 250 V AC
- Rated Control Circuit Voltage (U c ): 24 V DC
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85371091 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SFC132012C0201 |
| Instructions and Manuals | 1SFC132428M0201 |
| Instructions and Manuals (Part 2) | 1SFC132081M0201 |
| Instructions and Manuals (Part 3) | 1SFC132060M0201 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC184490_EPLAN |
| Wiring Diagram | N/A |
| Dimensions | |
| Product Net Width | 361 mm |
| Product Net Height | 493 mm |
| Product Net Depth / Length | 282 mm |
| Product Net Weight | 27 kg |
| Technical | |
| Rated Operational Voltage | 208 ... 690 V AC |
| Rated Control Supply Voltage (Us) | 100 ... 250 V AC |
| Rated Control Circuit Voltage (Uc) | 24 V DC |
| Rated Frequency (f) | 50/60 Hz |
| Main Circuit 50 / 60 Hz | |
| Rated Operational Power - In-Line Connection (Pe) | (230 V) 160 kW |
| (400 V) 315 kW | |
| (500 V) 400 kW | |
| (690 V) 560 kW | |
| Rated Operational Current - In-Line Connection (Ie) | 570 A |
| Rated Operational Power - Inside Delta Connection | at 230 V 295 kW |
| at 400 V 540 kW | |
| at 500 V 700 kW | |
| at 690 V 960 kW | |
| Rated Operational Current - Inside Delta Connection | 987 A |
| Service Factor Percentage | 100 % |
| Overload Protection | Built-in electronic overload protection |
| Integrated Electronic Overload | Yes |
| Starting Capacity at Maximum Rated Current Ie | 4xIe for 10s |
| Ramp Time | 1 ... 120 second [unit of time] |
| Initial Voltage During Start | 10 ... 99 % |
| Step Down Voltage Special Ramp | 100 ... 10 % |
| Switch for Inside Delta Connection | Yes |
| Run Signal Relay | Yes |
| By-pass Signal Relay | Yes |
| Fault Signal Relay | Yes |
| Overload Signal Relay | Yes |
| Signal Indication Ready to Start/Standby ON (LED) | Green |
| Signal Indication Running R (LED) | Green |
| Signal Indication Protection (LED) | Yellow |
| Signal Indication Fault (LED) | Red |
| Communication | Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Terminal Type | Main Circuit: Bars |
| Connecting Capacity Control Circuit | Rigid 1 x 2.5 mm² |
| Connecting Capacity Supply Circuit | Rigid 1 x 2.5 |
| Tightening Torque | Main Circuit 35 N·m |
| Product Main Type | PSTX570 |
| Function | Auto phase sequence detection |
| Automatic restart | |
| Current limit | |
| Current limit ramp | |
| Dual current limit | |
| Dynamic brake | |
| Electricity metering | |
| Electronic overload Time-to-cool | |
| Emergency mode | |
| Event log | |
| Full voltage start | |
| Jog with slow speed, forward and reverse | |
| Keypad password | |
| Kick start | |
| Limp mode with two-phase motor control if one set of thyristors is shorted | |
| Motor heating | |
| Pre-start function | |
| Pump cleaning | |
| Real time clock | |
| Sequence start | |
| Soft start with torque control | |
| Soft start with voltage ramp | |
| Soft stop with torque control | |
| Soft stop with voltage ramp | |
| Stand still brake | |
| Start reverse (external contactors) | |
| Thyristor runtime measurement | |
| Torque limit | |
| Voltage sags detection | |
| Protection Function | Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection |
| Warning Details | Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning |
| Technical UL/CSA | |
| Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 200 Hp |
| (220 ... 240 V AC) Three Phase 200 Hp | |
| (440 ... 480 V AC) Three Phase 500 Hp | |
| (550 ... 600 V AC) Three Phase 600 Hp | |
| Maximum Operating Voltage UL/CSA | Main Circuit 690 V |
| Tightening Torque UL/CSA | Main Circuit 309.8 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +70 °C | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2022-006481 |
| RoHS Declaration | 2CMT2022-006500 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006524 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| CQC Certificate | CN: CQC2015010304806588 / SE: CQC2015010304797766 |
| Declaration of Conformity - CCC | CN: 2020980304001094 / SE: 2020980304001859 |
| Declaration of Conformity - CE | 2CMT005209 |
| DNV Certificate | TAE000087N |
| Container Information | |
| Package Level 1 Width | 470 mm |
| Package Level 1 Depth / Length | 381 mm |
| Package Level 1 Height | 650 mm |
| Package Level 1 Gross Weight | 31 kg |
| Package Level 1 EAN | 7320500508978 |
| Package Level 1 Units | box 1 piece |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000640 - Soft starter |
| ETIM 8 | EC000640 - Soft starter |
| ETIM 9 | EC000640 - Soft starter |
| eClass | V11.0 : 27370907 |
| UNSPSC | 39121521 |
| IDEA Granular Category Code (IGCC) | 4740 >> Soft starter |