1SFA898110R7000 ABB Soft Starter 400V/75kW, 500V/90kW, 143A
1SFA898110R7000
898110
ABB
1 Pcs.
Automation > Soft starter
starters PSTX
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB solid-state soft starter provides reliable voltage ramp control for industrial three-phase motors, successfully eliminating high inrush current spikes and mechanical shock during startup cycles. This robust controller is widely implemented across manufacturing and process industries to protect drives and improve overall operational stability. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85371091
- Data Sheet, Technical Information: 1SFC132012C0201
- Instructions and Manuals: 1SFC132428M0201
- Instructions and Manuals (Part 2): 1SFC132081M0201
- Instructions and Manuals (Part 3): 1SFC132060M0201
- CAD Dimensional Drawing: 2CDC001079B0201
- EPLAN Data: 9AAC181166_EPLAN
- Wiring Diagram: N/A
- Product Net Width: 199 mm
- Product Net Height: 377 mm
- Product Net Depth / Length: 283 mm
- Product Net Weight: 7 kg
- Rated Operational Voltage: 208 ... 600 V AC
- Rated Control Supply Voltage (U s ): 100 ... 250 V AC
- Rated Control Circuit Voltage (U c ): 24 V DC
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85371091 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SFC132012C0201 |
| Instructions and Manuals | 1SFC132428M0201 |
| Instructions and Manuals (Part 2) | 1SFC132081M0201 |
| Instructions and Manuals (Part 3) | 1SFC132060M0201 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC181166_EPLAN |
| Wiring Diagram | N/A |
| Dimensions | |
| Product Net Width | 199 mm |
| Product Net Height | 377 mm |
| Product Net Depth / Length | 283 mm |
| Product Net Weight | 7 kg |
| Technical | |
| Rated Operational Voltage | 208 ... 600 V AC |
| Rated Control Supply Voltage (Us) | 100 ... 250 V AC |
| Rated Control Circuit Voltage (Uc) | 24 V DC |
| Rated Frequency (f) | 50/60 Hz |
| Main Circuit 50 / 60 Hz | |
| Rated Operational Power - In-Line Connection (Pe) | (230 V) 37 kW |
| (400 V) 75 kW | |
| (500 V) 90 kW | |
| Rated Operational Current - In-Line Connection (Ie) | 142 A |
| Rated Operational Power - Inside Delta Connection | at 230 V 75 kW |
| at 400 V 132 kW | |
| at 500 V 160 kW | |
| Rated Operational Current - Inside Delta Connection | 245 A |
| Service Factor Percentage | 100 % |
| Overload Protection | Built-in electronic overload protection |
| Integrated Electronic Overload | Yes |
| Starting Capacity at Maximum Rated Current Ie | 4xIe for 10s |
| Ramp Time | 1 ... 120 second [unit of time] |
| Initial Voltage During Start | 10 ... 99 % |
| Step Down Voltage Special Ramp | 100 ... 10 % |
| Current Limit Function | 1.5 ... 7.5 xle |
| Switch for Inside Delta Connection | Yes |
| Run Signal Relay | Yes |
| By-pass Signal Relay | Yes |
| Fault Signal Relay | Yes |
| Overload Signal Relay | Yes |
| Analog Outputs | 0…10 V, 0…20 mA, 4…20 mA |
| Signal Indication Ready to Start/Standby ON (LED) | Green |
| Signal Indication Running R (LED) | Green |
| Signal Indication Protection (LED) | Yellow |
| Signal Indication Fault (LED) | Red |
| Communication | Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Terminal Type | Main Circuit: Bars |
| Connecting Capacity Main Circuit | Hole Diameter 8.5 mm |
| Connecting Capacity Control Circuit | Rigid 1 x 2.5 mm² |
| Connecting Capacity Supply Circuit | Rigid 1 x 2.5 |
| Tightening Torque | Main Circuit 14 N·m |
| Product Main Type | PSTX142 |
| Function | Auto phase sequence detection |
| Automatic restart | |
| Current limit | |
| Current limit ramp | |
| Dual current limit | |
| Dynamic brake | |
| Electricity metering | |
| Electronic overload Time-to-cool | |
| Emergency mode | |
| Event log | |
| Full voltage start | |
| Jog with slow speed, forward and reverse | |
| Keypad password | |
| Kick start | |
| Limp mode with two-phase motor control if one set of thyristors is shorted | |
| Motor heating | |
| Pre-start function | |
| Pump cleaning | |
| Real time clock | |
| Sequence start | |
| Soft start with torque control | |
| Soft start with voltage ramp | |
| Soft stop with torque control | |
| Soft stop with voltage ramp | |
| Stand still brake | |
| Start reverse (external contactors) | |
| Thyristor runtime measurement | |
| Torque limit | |
| Voltage sags detection | |
| Protection Function | Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection |
| Warning Details | Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning |
| Technical UL/CSA | |
| Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 40 Hp |
| (220 ... 240 V AC) Three Phase 50 Hp | |
| (440 ... 480 V AC) Three Phase 100 Hp | |
| (550 ... 600 V AC) Three Phase 125 Hp | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| Tightening Torque UL/CSA | Main Circuit 123.9 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +70 °C | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2022-006481 |
| RoHS Declaration | 2CMT2022-006500 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 26f21088-b8bb-4914-b092-1fc09456661d China |
| Simplified SCIP | 0ab76afe-9586-406c-b1d9-3f72d29c6360 Netherlands |
| 117db3bc-26f8-486b-9661-9213c47e0dce Germany | |
| 13efe971-0aef-4a3e-b200-9388f7b13699 Sweden | |
| 14290cdf-4981-4228-ac25-fbf6ff6bede1 Poland | |
| 2a18edcd-ab8d-49d6-9e8e-a36742111f1c Belgium | |
| 3833bc73-a767-402d-b8b2-abad0c0099a9 Norway | |
| 3ac3b2ef-d72e-4baa-a85b-7a6308c05cd5 France | |
| 3ce45bbe-7f17-4746-a062-621c143a1593 Belgium | |
| 45148e2f-b3ab-4084-a4ff-2d3992dff4e3 Greece | |
| 483327c0-4c3f-426a-8884-5793dc883e80 Germany | |
| 4895692a-8d27-4479-86bf-173e094805d8 Finland | |
| 693ca665-b359-42b9-8505-0a1d73f17bb1 Croatia | |
| 721706c8-8f98-4edd-93f6-85eb76f49408 Sweden | |
| 734b7456-6afc-4ba5-9eb1-e44eb712b188 Estonia | |
| 7c8972af-46d8-45d8-9928-ca11c959706a Bulgaria | |
| 84993a02-0bda-48c2-a072-0f582e778ff3 Hungary | |
| 9601f0fb-71c8-46d6-901c-b0c11e41b94c Germany | |
| 98705313-f7c3-4ad9-bc8e-c866590c7b4c Germany | |
| a46c12be-e940-4ade-9322-97a2ddebbaed Portugal | |
| a7d57835-a734-4c2d-9f77-81733f7491bf Hungary | |
| ced2cf36-a96f-4b81-ac85-517042ee7ef1 Germany | |
| d73af370-e733-4369-9550-2ae47c351b48 Poland | |
| d8506a36-85a5-4e05-9a69-9b4c090cc148 Spain | |
| e079558d-a47b-4f28-8edf-f04ab44fd258 France | |
| e7f3ccdd-9d79-4c97-84ad-b4c479119f1b Poland | |
| ef546eb4-0fda-49d8-947c-db988a7a5730 Czech Republic | |
| f3952e38-6433-4473-9a54-aee6eac8f612 Denmark | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006524 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| CQC Certificate | CN: CQC2014010304744407 / SE: CQC2014010304724379 |
| Declaration of Conformity - CCC | CN: 2020980304001092 / SE: 2020980304001485 |
| Declaration of Conformity - CE | 2CMT005209 |
| DNV Certificate | TAE000087N |
| Container Information | |
| Package Level 1 Width | 263 mm |
| Package Level 1 Depth / Length | 323 mm |
| Package Level 1 Height | 454 mm |
| Package Level 1 Gross Weight | 8.7 kg |
| Package Level 1 EAN | 7320500501467 |
| Package Level 1 Units | box 1 piece |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000640 - Soft starter |
| ETIM 8 | EC000640 - Soft starter |
| ETIM 9 | EC000640 - Soft starter |
| eClass | V11.0 : 27370907 |
| UNSPSC | 39121521 |
| IDEA Granular Category Code (IGCC) | 4740 >> Soft starter |