View larger
2CTB803973R1100 ABB OVR T2 3N 40-275 P QS
2CTB803973R1100
803973
ABB
1 Pcs.
Automation > Surge protection device for power supply systems
OVR surge protection
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb OVR T2 3N 40-275 P QS (2CTB803973R1100) serves as a specialized surge protection device built to safeguard industrial control panels and low-voltage distribution grids from destructive transient voltage spikes. These protective elements are commonly installed upstream to limit residual overvoltages and protect connected electronics.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Environmental Product Declaration - EPD: 9AKK108468A7418
- Type of Low Voltage Distribution System: TT
- Suitable For: To protect the systems against the transient overvoltage (lightning)
- Nominal AC Voltage of the System (U o ): 230 / 400 V
- Maximum Continuous Operating Voltage (U c ): (L-PE) 275 V
- Temporary Overvoltage Test Value (U T ): (L-N) 337 V
- Rated Service Short-Circuit Breaking Capacity (I cs ): 100 kA
- Discharge Current: Nominal (8 / 20 µs): 20 kA
- Impulse Current: I (imp, 10 / 350 µs): 2 kA
- Short Circuit Withstand Icc: 100 kA
- Arrester Class: II
- Number of Protected Poles: 4
- Number of Poles: 4P
- Number of Conductors: 4
- Position of Neutral Terminals: Right
- Transmission Standard: Optic
More info
▲| ABB EcoSolutions | |
|---|---|
| Environmental Product Declaration - EPD | 9AKK108468A7418 |
| Technical | |
| Type of Low Voltage Distribution System | TT |
| TN-S | |
| Suitable For | To protect the systems against the transient overvoltage (lightning) |
| Nominal AC Voltage of the System (Uo) | 230 / 400 V |
| Maximum Continuous Operating Voltage (Uc) | (L-PE) 275 V |
| Temporary Overvoltage Test Value (UT) | (L-N) 337 V |
| (N-PE) 1200 V | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | 100 kA |
| Discharge Current | Nominal (8 / 20 µs) 20 kA |
| I (max, 8 / 20 µs) 40 kA | |
| Impulse Current | I (imp, 10 / 350 µs) 2 kA |
| Short Circuit Withstand Icc | 100 kA |
| Arrester Class | II |
| Number of Protected Poles | 4 |
| Number of Poles | 4P |
| Number of Conductors | 4 |
| Position of Neutral Terminals | Right |
| Transmission Standard | Optic |
| Version | Plug-in |
| Product Type | QS |
| Options Provided | Residential, commercial building. |
| Auxiliary Circuit Load | Minimum - |
| Maximum - | |
| Preventive Maintenance Feature | No |
| Status Indicator | Yes |
| Fuse Size | 4 modular spacing |
| Cross-Section (Across) | Maximum Conductor Solid-Stranded 25 mm² |
| Maximum Conductor Flexible 16 mm² | |
| Electrical | |
| Rated Voltage (Ur) | 230 V AC |
| Voltage Protection Level ( Up) | 1.5 kV |
| (L-N) 1.25 kV | |
| (N-PE) 1.4 kV | |
| Power Loss | Total 29 mW |
| Material Compliance | |
| RoHS Declaration | 9AKK108466A4410 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20230707 |
| REACH Declaration | 9AKK107492A1906 |
| REACH Information | False - does not contain substances > 0.1 mass percentage |
| REACH Date | 20231212 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Consumer |
| Environmental | |
| Degree of Protection | IP20 |
| Maximum Operating Altitude Permissible | Without Derating 5000 |
| Dimensions | |
| Width in Number of Modular Spacings | 4 |
| Product Net Width | 71.2 mm |
| Product Net Height | 88 mm |
| Product Net Depth / Length | 58 mm |
| Product Net Weight | 0.48 kg |
| Engineering | |
| EPLAN Data | 9AAC183885_EPLAN |
| Ordering | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 500 g |
| E-Number (Finland) | 3210885 |
| E-Number (Norway) | 1672320 |
| Certificates and Declarations | |
| CB Certificate | 2CTC432024G1701 |
| CQC Certificate | 9AKK107680A1974 |
| Declaration | 2CTC432056G1701 |
| Declaration of Conformity - CE | 9AKK108466A4410 |
| Installation | |
| Instructions and Manuals | 2CTC432096M1701 |
| Mounting Type | DIN-Rail |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CTC432245D0201 |
| Mechanical Drawings | 2CTC800021F1300.pdf |
| 2CTC800021F1301.dxf | |
| 2CTC800021F1302.stp | |
| 2CTC800021F1303.igs | |
| External Classifications and Standards | |
| ETIM 9 | EC000941 - Surge protection device for power supply systems |
| ETIM 10 | EC000941 - Surge protection device for power supply systems |
| UNSPSC | 39121610 |
| eClass | V11.0 : 27130805 |
| Object Classification Code | 141DCC |
| Standards | IEC 61643-11 / EN 61643-11 |