View larger
2CTB815710R0700 ABB OVR T1-T2 3N 12.5-275s P TS QS
2CTB815710R0700
815710
ABB
1 Pcs.
Automation > Combined arrester for power supply systems
OVR surge protection
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 2CTB815710R0700 OVR T1-T2 surge protective device shields low-voltage electrical distribution networks from transient voltage spikes caused by distant lightning strikes or switching operations. Multi-pole combination arresters are installed in main distribution boards for complete facility protection. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Environmental Product Declaration - EPD: 9AKK108468A7418
- Type of Low Voltage Distribution System: TT
- Suitable For: To protect the systems against the transient overvoltage (lightning)
- Nominal AC Voltage of the System (U o ): 230 / 400 V
- Maximum Continuous Operating Voltage (U c ): (L-PE) 275 V
- Temporary Overvoltage Test Value (U T ): (L-N) 337 V
- Discharge Current: Nominal 20 kA
- Impulse Current: I (imp, 10 / 350 µs) 12.5 kA
- Lightning Impulse Current: 12.5 kA
- Short Circuit Withstand Icc: 100 kA
- Follow Current Extinction Capacity If (I fi): (L-N) - kA
- Short-Circuit Protective Devices: Curve B Breakers ≤ 125 A
- Arrester Class: I
- Number of Protected Poles: 4
- Number of Auxiliary Contacts NC: 1
- Number of Auxiliary Contacts NO: 1
More info
▲| ABB EcoSolutions | |
|---|---|
| Environmental Product Declaration - EPD | 9AKK108468A7418 |
| Technical | |
| Type of Low Voltage Distribution System | TT |
| TN-S | |
| Suitable For | To protect the systems against the transient overvoltage (lightning) |
| Nominal AC Voltage of the System (Uo) | 230 / 400 V |
| Maximum Continuous Operating Voltage (Uc) | (L-PE) 275 V |
| (L-L) 440 V | |
| (L-N) 275 V | |
| (N-PE) 255 V | |
| Temporary Overvoltage Test Value (UT) | (L-N) 337 V |
| (N-PE) 1200 V | |
| Discharge Current | Nominal 20 kA |
| Maximum 80 kA | |
| Total 100 kA | |
| Impulse Current | I (imp, 10 / 350 µs) 12.5 kA |
| I (total, 10 / 350 µs) 50 kA | |
| Lightning Impulse Current | 12.5 kA |
| Short Circuit Withstand Icc | 100 kA |
| Follow Current Extinction Capacity If (I fi) | (L-N) - kA |
| (N-PE) 0.1 kA | |
| Short-Circuit Protective Devices | Curve B Breakers ≤ 125 A |
| Curve C Breakers ≤ 125 A | |
| gL Type Fuses ≤ 160 A | |
| gG Type Fuses ≤ 160 A | |
| Arrester Class | I |
| II | |
| Number of Protected Poles | 4 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Poles | 4P |
| Position of Neutral Terminals | Right |
| Version | Plug-in |
| Product Type | QS |
| Options Provided | Industry, commercial building |
| Auxiliary Circuit Load | Minimum 12Vdc - 10mA |
| Maximum 250Vac - 1A | |
| Preventive Maintenance Feature | Yes |
| Status Indicator | Yes |
| Fuse Size | 4 modular spacing |
| Electrical | |
| Voltage Protection Level ( Up) | (L-N) 1.4 kV |
| (N-PE) 1.4 kV | |
| (L-PE) 1.5 kV | |
| Power Loss | Total 63 mW |
| Material Compliance | |
| RoHS Declaration | 9AKK108466A4617 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20230707 |
| REACH Declaration | 9AKK107492A1906 |
| REACH Information | False - does not contain substances > 0.1 mass percentage |
| REACH Date | 20231212 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| SCIP | eb870ea9-6bc9-4c32-80f0-da19296d1169 Bulgaria |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Business |
| Environmental | |
| Degree of Protection | IP20 |
| Maximum Operating Altitude Permissible | Without Derating 5000 |
| Dimensions | |
| Width in Number of Modular Spacings | 4 |
| Product Net Width | 71.2 mm |
| Product Net Height | 95.8 mm |
| Product Net Depth / Length | 76.7 mm |
| Product Net Weight | 0.6 kg |
| Ordering | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 0.600 kg |
| E-Number (Finland) | 3217660 |
| E-Number (Norway) | 1623935 |
| Certificates and Declarations | |
| CQC Certificate | 9AKK107680A1975 |
| Declaration | 2CTC432056G1701 |
| Declaration of Conformity - CE | 9AKK108466A4617 |
| Installation | |
| Instructions and Manuals | 2CTC431030M1701 |
| Mounting Type | DIN-Rail |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CTC431039D0201 |
| Mechanical Drawings | 2CTC800015F1200.pdf |
| 2CTC800015F1201.dxf | |
| 2CTC800015F1202.stp | |
| 2CTC800015F1203.igs | |
| External Classifications and Standards | |
| ETIM 9 | EC001457 - Combined arrester for power supply systems |
| ETIM 10 | EC001457 - Combined arrester for power supply systems |
| UNSPSC | 39121610 |
| eClass | V11.0 : 27130808 |
| Object Classification Code | 141BCC |
| Standards | IEC 61643-11 / EN 61643-11 |