ABB 2CTB815710R0100 2CTB815710R0100 ABB OVR T1-T2 1N 12.5-275s P TS QS View larger
Images are for illustrative purposes only. Please refer to data sheet for details

2CTB815710R0100 ABB OVR T1-T2 1N 12.5-275s P TS QS

2CTB815710R0100

815710

ABB

1 Pcs.

OVR T1-T2 1N 12.5-275s P TS QS Prot.sobret. OVRT1-T21N12.5-275sPTSQS

Automation > Combined arrester for power supply systems
OVR surge protection

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

OVR T1-T2 1N 12.5-275s P TS QS

Ordering

  • Product Main Type:
    T1-T2
  • EAN:
    3660308524898
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85363090

Technical

  • Type of Low Voltage Distribution System:
    TT
    TN-S
  • Nominal AC Voltage of the System (Uo):
    230 / 400 V
  • Number of Protected Poles:
    2
  • Arrester Class:
    I
    II
  • Standards:
    IEC 61643-11 / EN 61643-11
  • Product Type:
    QS
  • Remote Indicator:
    Yes
  • Version:
    Plug-in
  • Discharge Current (Imax):
    Nominal 12.5 kA
    Maximum 80 kA
    Total 100 kA
  • Impulse Current:
    12.5 kA
  • Maximum Continuous Operating Voltage (Uc):
    (L-PE) 275 V
    (L-L)- V
    (L-N) 275 V
    (N-PE) 275 V
  • Voltage Rating DC:
    350 V
  • Voltage Protection Level ( Up):
    (L-N) 1.2 kV
    (N-PE) 1.1 kV
    (L-PE) 1.35 kV
  • Short Circuit Withstand Icc:
    100 kA
  • Temporary Overvoltage Test Value (UT):
    (L-N) 337 V
    (N-PE) 1200 V
  • Short-Circuit Protective Devices:
    Curve B Breakers ≤ 125 A
    Curve C Breakers ≤ 125 A
    gL Type Fuses ≤ 160 A
    gG Type Fuses ≤ 160 A
  • Auxiliary Circuit Load:
    Minimum 12Vdc - 10mA
    Maximum 250Vac - 1A
  • Power Loss:
    37 mW
  • Product Name:
    Surge Protective Devices
  • Suitable For:
    To protect the systems against the transient overvoltage (lightning)

Dimensions

  • Product Net Width:
    35.6mm
  • Product Net Depth:
    76.7mm
  • Product Net Height:
    95.8mm
  • Product Net Weight:
    300g
  • Width in Number of Modular Spacings:
    2

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    117 mm
  • Package Level 1 Length:
    41 mm
  • Package Level 1 Height:
    82 mm
  • Package Level 1 Gross Weight:
    320 g
  • Package Level 1 EAN:
    3660308524898

Certificates and Declarations (Document Number)

Classifications

  • ETIM 4:
    EC001457 - Combined arrester for power supply systems
  • ETIM 5:
    EC001457 - Combined arrester for power supply systems

ETIM for 2CTB815710R0100 Earthing, lightning and surge protection (EC001457)
Feature Name Feature Value
System configuration DC (EF009926) No
System configuration IT (EF009927) No
System configuration TN (EF009928) No
System configuration TN-C (EF009929) No
System configuration TN-C-S (EF009933) No
System configuration TN-S (EF009930) Yes
System configuration TT (EF009931) Yes
System configuration other (EF009932) No
Number of poles (EF001391) 2
Voltage protection level L-N (EF004236) 1.4 kV
Voltage protection level L-PE (EF012276) 1.5 kV
Voltage protection level N-PE (EF008796) 1.4 kV
Construction size (EF002566) 2 modular spacing
Remote signalling (EF004192) Yes
Integrated backup fuse (EF008797) No
Energy-coordinated protection effect with regard to the terminal equipment (EF009798) No
Voltage switching spark gap technology (EF016003) No
Overcurrent protected voltage tapping (EF016004) No
Degree of protection (IP) (EF005474) IP20

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.