View larger
Images are for illustrative purposes only. Please refer to data sheet for details
1SCA104935R1001 ABB Switch disconnector OT40F4N1
1SCA104935R1001
104935
ABB
1 Pcs.
Switch disconnector OT40F4N1
OT40F4N1 disconnect switch
OT40F4N1 SWITCH-DISCONNECTOR
Connectors > Switch disconnector
Manual Switches
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb switch disconnector provides robust manual load breaking and safety isolation in industrial power distribution systems. This component safely interrupts electrical circuits to prevent accidental startup during facility maintenance.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Environmental Information: 1SCC301262D0201
- Environmental Product Declaration - EPD: 1SCC301278D0201
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- REACH Declaration: 1SCC011021D0201
- RoHS Declaration: 1SCC011020D0201
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Toxic Substances Control Act - TSCA: 1SCC011025D0201
- Data Sheet, Technical Information: No documentation needed
- Instructions and Manuals: 1SCC301052M0006
- Mechanical Drawings: 1SCC301709F0001
- Environmental Product Declaration - EPD: 1SCC301278D0201
- Degree of Protection: Front IP20
- Environmental Information: 1SCC301262D0201
- Pollution Degree: 3
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85365080
More info
▲| ABB EcoSolutions | |
|---|---|
| Environmental Information | 1SCC301262D0201 |
| Environmental Product Declaration - EPD | 1SCC301278D0201 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SCC011021D0201 |
| RoHS Declaration | 1SCC011020D0201 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 1SCC011025D0201 |
| Popular Downloads | |
| Data Sheet, Technical Information | No documentation needed |
| Instructions and Manuals | 1SCC301052M0006 |
| Mechanical Drawings | 1SCC301709F0001 |
| 1SCC301708F0001 | |
| OT16-40F4N1.igs | |
| Environmental Product Declaration - EPD | 1SCC301278D0201 |
| Environmental | |
| Degree of Protection | Front IP20 |
| Environmental Information | 1SCC301262D0201 |
| Pollution Degree | 3 |
| Ordering | |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Country or Territory of Origin | Finland |
| Dimensions | |
| Product Net Width | 48 mm |
| Product Net Height | 68 mm |
| Product Net Depth / Length | 56 mm |
| Product Net Weight | 0.125 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 67 mm |
| Package Level 1 Depth / Length | 79 mm |
| Package Level 1 Height | 61 mm |
| Package Level 1 Gross Weight | 0.14 kg |
| Package Level 1 EAN | 6417019390758 |
| Technical | |
| Cable Cross-Section | Cu 0.75 ... 10 mm² |
| Conventional Thermal Current (Ithe) | Fully Enclosed 40 A |
| Degree of Protection | Front IP20 |
| Handle Type | Knob |
| Handle and shaft not included | |
| Mechanical Durability | 20000 |
| Number of Poles | 4P |
| Pollution Degree | 3 |
| Power Loss | at Rated Operating Conditions per Pole 1.6 W |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 750 V |
| Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 40 A |
| (500 V) 40 A | |
| (690 V) 40 A | |
| Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 23 A |
| (500 V) 23 A | |
| (690 V) 12 A | |
| Rated Operational Power AC-23A (Pe) | (220 ... 240 V) 5.5 kW |
| (400 ... 415 V) 11 kW | |
| (500 V) 11 kW | |
| (690 V) 11 kW | |
| Rated Operational Voltage | Main Circuit 750 V |
| Rated Short-Circuit Making Capacity (Icm) | (690 V) 0.71 kA |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 0.5 kA |
| Standards | IEC 60947-3 / UL 508 / CSA C22.2 No. 14 |
| Terminal Type | Screw Terminals |
| Tightening Torque | acc. IEC 60947-1 0.8 N·m |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | 600 V |
| Ampere Rating | 40 A |
| Horsepower Rating UL/CSA | (110 ... 120 V AC) Single Phase 2 Hp |
| (240 V AC) Single Phase 5 Hp | |
| (440 ... 480 V AC) Single Phase 10 Hp | |
| (550 ... 600 V AC) Single Phase 15 Hp | |
| (220 ... 240 V AC) Three Phase 10 Hp | |
| (440 ... 480 V AC) Three Phase 20 Hp | |
| (550 ... 600 V AC) Three Phase 25 Hp | |
| Tightening Torque | acc. IEC 60947-1 0.8 N·m |
| Certificates and Declarations | |
| A2L Certificate – IEC | 1SCC301335D0201 |
| Declaration of Conformity - CE | 1SCC301166D2703 |
| UL Certificate | cULus certificate OT16-80 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 9 | EC000216 - Switch disconnector (low voltage) |
| ETIM 10 | EC000216 - Switch disconnector (AC) |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| E-Number (Sweden) | 3135076 |