View larger
1SCA022721R3990
022721
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| End Of Life Disassembling Instructions | 1SCC301117M0201 |
| Environmental Information | 1SCC301265D0201 |
| Environmental Product Declaration - EPD | 1SCC301282D0201 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SCC011021D0201 |
| RoHS Declaration | 1SCC011020D0201 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 6a0d8600-a7e4-4abd-87f5-af992511d65a Finland |
| Simplified SCIP | 299a92fb-dacc-4726-b3ca-147e262029a3 Germany |
| 17021e57-4bb8-41ac-9955-e541ea54b11c Bulgaria | |
| e3170685-d2c4-45d6-89f1-2368fe61292f Sweden | |
| 25625226-d18f-4211-9008-2c7101f07362 France | |
| cb7cfcfc-5bfb-422e-bab5-537157bd4166 Germany | |
| 0a7d4edb-3a51-4ae8-9c5c-eaaf61ea6a63 Denmark | |
| 5dcdf3e0-615b-4111-b8db-6b5da5a161ef Belgium | |
| 15400c71-9dfe-44b9-887b-43d78f835d33 France | |
| cd08ef14-7cdc-4589-9fbc-053a010b2d56 Poland | |
| dbea7483-761d-441d-ae8c-aca7dc226c04 Hungary | |
| 7a61d69e-5f69-48f7-a8d6-6f44a537a063 Italy | |
| 1b3c2c0f-fbd2-4ed8-bd40-49b71ee688db Estonia | |
| 074d5656-99b6-4000-b5b6-42549848a179 Netherlands | |
| ebf6770c-52ed-44c3-91de-05c854d3b492 Hungary | |
| 80d6a693-9105-4ce3-aaa5-6596c802c7cf Norway | |
| e15fd24b-7172-447b-bd92-733051849ffe Sweden | |
| 65ae29c7-3c5d-4701-b688-65495ca754aa Germany | |
| 5c15d01f-aa9f-457a-973f-2c5b5f83c063 Croatia | |
| 16f9582f-3804-4bb4-baac-9e19e8f1d2c0 Germany | |
| c265d4b2-0e37-47bd-8f65-e939c0194bb0 Czech Republic | |
| b9db2595-3375-4faf-8446-191f7aeedab8 Poland | |
| f9beeeb0-c812-40f2-a1a3-2cde3fe72c97 Germany | |
| bf07771c-f947-4edb-9f58-0dc2a103d8ba Spain | |
| f5e7739e-8f4d-45bd-b643-f990edee69ab Poland | |
| 6de35f16-785c-4c84-beb2-eff2ad2c2fbf Belgium | |
| f6cd2e04-9428-4c61-bfbe-01cb4c8e7c80 Portugal | |
| 640d6867-eb95-4f68-963e-1a84c6c5f183 Greece | |
| Toxic Substances Control Act - TSCA | 1SCC011025D0201 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SCC301020C0201 |
| Instructions and Manuals | 1SCC301031M0220 |
| Mechanical Drawings | 1SCC301228F0001 |
| 1SCC301227F0001 | |
| OT200-250E12.igs | |
| Environmental Product Declaration - EPD | 1SCC301282D0201 |
| Environmental | |
| Degree of Protection | Front IP00 |
| Environmental Information | 1SCC301265D0201 |
| Pollution Degree | 3 |
| Ordering | |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Country or Territory of Origin | Finland |
| Dimensions | |
| Product Net Width | 150.5 mm |
| Product Net Height | 150 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 1.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 170 mm |
| 6.7 in | |
| Package Level 1 Depth / Length | 190 mm |
| 7.5 in | |
| Package Level 1 Height | 145 mm |
| 5.7 in | |
| Package Level 1 Gross Weight | 1.6 kg |
| 3.6 lb | |
| Package Level 1 EAN | 6417019231761 |
| Technical | |
| Conventional Free-air Thermal Current (Ith) | Θ = 40 °C 200 A |
| Conventional Thermal Current (Ithe) | Fully Enclosed 200 A |
| Degree of Protection | Front IP00 |
| Distance Between Phases | Standard |
| Handle Color | Black |
| Handle Type | Handle and shaft included |
| Mechanical Durability | 20000 |
| Mounting Type | Base mounting |
| Number of Poles | 3P |
| Operating Mode | Front |
| Pollution Degree | 3 |
| Position of Line Terminals | Top In - Bottom Out |
| Bottom In - Top Out | |
| Power Loss | at Rated Operating Conditions per Pole 4.0 W |
| Rated Conditional Short-Circuit Current (Inc) | (315 A fuse, 500 V) 100 kA |
| (355 A fuse, 690 V) 80 kA | |
| (250 A fuse, 690 V) 100 kA | |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 1000 V |
| Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 200 A |
| (500 V) 200 A | |
| (690 V) 200 A | |
| Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 200 A |
| (500 V) 200 A | |
| (690 V) 200 A | |
| Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 200 A |
| (500 V) 200 A | |
| (690 V) 200 A | |
| Rated Operational Power AC-23A (Pe) | (220 ... 240 V) 60 kW |
| (400 ... 415 V) 110 kW | |
| (500 V) 132 kW | |
| (690 V) 200 kW | |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Short-Circuit Making Capacity (Icm) | (690 V) 30 kA |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 8 kA |
| Special Functions | No |
| Standards | IEC 60947-3 |
| Switches Operating Mechanism | Mechanism Between the Poles |
| 12 (Between the Poles) | |
| Terminal Type | Lug terminals |
| Terminal Width | 20 mm |
| Tightening Torque | acc. IEC 60947-1 15 … 22 N·m |
| Technical UL/CSA | |
| Tightening Torque | acc. IEC 60947-1 15 … 22 N·m |
| Certificates and Declarations | |
| A2L Certificate – IEC | 1SCC301337D0201 |
| ATEX Certificate | No certification needed |
| BV Certificate | 1SCC301103D0201 |
| Declaration of Conformity - CE | 1SCC301131D2705 |
| DNV GL Certificate | 1SCC301174D0204 |
| GL Certificate | 1SCC301139D0201 |
| LR Certificate | 1SCC301144D0201 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 9 | EC000216 - Switch disconnector (low voltage) |
| ETIM 10 | EC000216 - Switch disconnector (AC) |
| UNSPSC | 39122221 |
| eClass | V11.1 : 27371403 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| E-Number (Finland) | 3661314 |
| E-Number (Norway) | 4337854 |
| E-Number (Sweden) | 3171158 |
| Feature Name | Feature Value |
|---|---|
| Version as main switch (EF006981) | Yes |
| Version as maintenance-/service switch (EF006986) | Yes |
| Version as safety switch (EF006985) | No |
| Version as emergency stop installation (EF006959) | No |
| Version as reversing switch (EF009408) | No |
| Number of switches (EF005586) | 1 |
| Max. rated operation voltage Ue AC (EF007355) | 1000 V |
| Rated operating voltage (EF001435) | 1000 V |
| Rated permanent current Iu (EF001389) | 200 A |
| Rated permanent current at AC-23, 400 V (EF011777) | 200 A |
| Rated permanent current at AC-21, 400 V (EF009165) | 200 A |
| Rated short-time withstand current lcw (EF007050) | 8 kA |
| Rated operation power at AC-23, 400 V (EF007027) | 110 kW |
| Switching power at 400 V (EF009166) | 110 kW |
| Conditioned rated short-circuit current Iq (EF001444) | 100 kA |
| Number of poles (EF001391) | 3 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| Motor drive optional (EF007386) | No |
| Motor drive integrated (EF006697) | No |
| Voltage release optional (EF007491) | No |
| Device construction (EF008240) | Complete device in housing |
| Suitable for front mounting 4-hole (EF007247) | No |
| Suitable for front mounting centre (EF007248) | No |
| Suitable for distribution board installation (EF007262) | Yes |
| Colour control element (EF007167) | Black |
| Type of control element (EF006976) | Long turning handle |
| Interlockable (EF006281) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Degree of protection (IP), front side (EF003118) | IP00 |
| Degree of protection (NEMA) (EF011959) | Other |