View larger
1SCA022775R9440
022775
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| End Of Life Disassembling Instructions | 1SCC303050M0201 |
| Environmental Information | 1SCC303050D0201 |
| Environmental Product Declaration - EPD | 1SCC303082D0201 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SCC011021D0201 |
| RoHS Declaration | 1SCC011020D0201 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | ef556fd6-d19c-413f-9e9e-d3c9254c1212 Finland |
| Simplified SCIP | 324a34e6-d92d-4659-a6c8-7f25a4f8202b Germany |
| 7c18e3c7-d4ec-4daf-8638-780bbf725e49 Poland | |
| 79c4eb22-50d4-41d7-b6fd-bcff65221f82 France | |
| 4d6acfff-dd17-4d78-91eb-c4efa115ccbb Italy | |
| 80a8fc45-5222-4a61-b2bb-cd8ada25cd84 Hungary | |
| 3fb9d9d1-b0ec-48a0-b098-940168200189 Portugal | |
| 875993c2-42d9-40c9-8cdd-7006fcb6b022 Denmark | |
| 20dca2da-2029-44e5-bc86-a6a6d2955a4c Netherlands | |
| f1d6782a-92e7-413e-9486-5ed4054328d2 Croatia | |
| f0df47b8-615f-451e-8563-b1c5b1fd5c02 Sweden | |
| 350d11eb-0249-452b-9052-f77d05c23e55 Belgium | |
| f6a04649-2730-4919-84da-c107d80945be Germany | |
| 2a72d88d-2b17-43f0-8a3c-603368363d33 France | |
| 95051c22-70dd-4564-a5f9-22998b562a26 Spain | |
| 34bb405e-7eda-448a-9a24-f11b0ca1dba3 Greece | |
| c83908be-bffc-402d-9cec-d1d90f8d72dd Bulgaria | |
| 9a289f65-5d22-4279-9c5a-d081354c7cd6 Germany | |
| 57761068-7ebf-4acc-a6aa-7f2c079edf4c Hungary | |
| ee15fe22-2944-4a25-af0e-16a5faa4c162 Germany | |
| e170c76c-8bdd-4cfc-a218-eb1f693dc8a9 Poland | |
| f2aa8062-9e30-4c1c-96ea-d1dd0635ce41 Estonia | |
| 35b6d0d9-9b97-4594-b3ef-fb99b3e020d2 Czech Republic | |
| d6f0b348-e327-4b1f-9520-875b77c7557a Poland | |
| 82455908-5079-42f3-82f5-8ca070c43ef8 Germany | |
| 16a10f02-3901-4446-8cad-5d694b132d89 Norway | |
| f4c000b0-fdd4-432b-bea1-c3033ad8b8e0 Belgium | |
| 0f58dfe3-0f6c-4a7a-8ca8-b63776cb2f88 Sweden | |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SCC303003C0201 |
| Instructions and Manuals | 1SCC303008M0208 |
| Environmental Product Declaration - EPD | 1SCC303082D0201 |
| Environmental | |
| Degree of Protection | Front IP20 |
| Environmental Information | 1SCC303050D0201 |
| Pollution Degree | 3 |
| Ordering | |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Country or Territory of Origin | Finland |
| Dimensions | |
| Product Net Width | 205 mm |
| 8.07 in | |
| Product Net Height | 150 mm |
| 5.91 in | |
| Product Net Depth / Length | 160 mm |
| 6.3 in | |
| Product Net Weight | 3.3 kg |
| 7.28 lb | |
| Container Information | |
| Package Level 1 Units | box 1 box |
| Package Level 1 Width | 160 mm |
| 6.3 in | |
| Package Level 1 Depth / Length | 270 mm |
| 10.63 in | |
| Package Level 1 Height | 185 mm |
| 7.28 in | |
| Package Level 1 Gross Weight | 4.05 kg |
| 8.93 lb | |
| Package Level 1 EAN | 6417019252551 |
| Technical | |
| Conventional Free-air Thermal Current (Ith) | Θ = 40 °C 160 A |
| Conventional Thermal Current (Ithe) | Fully Enclosed 160 A |
| Degree of Protection | Front IP20 |
| Distance Between Phases | Standard |
| Fourth Pole Position | Right Side |
| Fourth Pole Type | Switched - Simultaneous Function |
| Handle Color | Black |
| Handle Type | Handle and shaft included |
| Mounting Type | Base mounting |
| Number of Poles | 4P |
| Operating Mode | Front |
| Pollution Degree | 3 |
| Position of Line Terminals | Top In - Bottom Out, Bottom In - Top Out |
| Power Loss | at Rated Operating Conditions per Pole 2.4 W |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 160 A |
| (500 V) 160 A | |
| (690 V) 160 A | |
| Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 160 A |
| (500 V) 160 A | |
| (690 V) 160 A | |
| Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 160 A |
| (500 V) 160 A | |
| (690 V) 160 A | |
| Rated Operational Current AC-31B (Ie) | (380 ... 415 V) 160 A |
| Rated Operational Current AC-33B (Ie) | (380 ... 415 V) 160 A |
| Rated Operational Power AC-23A (Pe) | (380 ... 415 V) 90 kW |
| (500 V) 110 kW | |
| (690 V) 160 kW | |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 8 kiloampere rms |
| Switches Operating Mechanism | Mechanism at the End of the Switch |
| 04 (Left Side) | |
| Terminal Type | Screw Terminals |
| Terminal Width | 20 mm |
| Tightening Torque | acc. IEC 60947-1 15 ... 22 N·m |
| Transition Type | Open |
| Technical UL/CSA | |
| Tightening Torque | acc. IEC 60947-1 15 ... 22 N·m |
| Certificates and Declarations | |
| Declaration of Conformity - CE | 1SCC303001D2704 |
| DNV Certificate | 1SCC303138D0201 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 9 | EC000216 - Switch disconnector (low voltage) |
| ETIM 10 | EC000216 - Switch disconnector (AC) |
| UNSPSC | 39122233 |
| eClass | V11.1 : 27371403 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| E-Number (Finland) | 3641526 |
| E-Number (Norway) | 4337000 |
| Feature Name | Feature Value |
|---|---|
| Version as main switch (EF006981) | Yes |
| Version as maintenance-/service switch (EF006986) | Yes |
| Version as safety switch (EF006985) | No |
| Version as emergency stop installation (EF006959) | No |
| Version as reversing switch (EF009408) | No |
| Number of switches (EF005586) | 1 |
| Max. rated operation voltage Ue AC (EF007355) | 1000 V |
| Rated operating voltage (EF001435) | 1000 V |
| Rated permanent current at AC-23, 400 V (EF011777) | 160 A |
| Rated permanent current at AC-21, 400 V (EF009165) | 160 A |
| Rated short-time withstand current lcw (EF007050) | 8 kA |
| Rated operation power at AC-23, 400 V (EF007027) | 90 kW |
| Switching power at 400 V (EF009166) | 90 kW |
| Number of poles (EF001391) | 4 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| Motor drive optional (EF007386) | No |
| Motor drive integrated (EF006697) | No |
| Voltage release optional (EF007491) | No |
| Device construction (EF008240) | Built-in device plug-in technique |
| Suitable for front mounting 4-hole (EF007247) | Yes |
| Suitable for front mounting centre (EF007248) | No |
| Suitable for distribution board installation (EF007262) | Yes |
| Suitable for intermediate mounting (EF007264) | No |
| Colour control element (EF007167) | Black |
| Type of control element (EF006976) | Long turning handle |
| Interlockable (EF006281) | Yes |
| Type of electrical connection of main circuit (EF006819) | Other |
| Degree of protection (IP), front side (EF003118) | IP20 |
| Degree of protection (NEMA) (EF011959) | 1 |