View larger
1SCA022721R3050 ABB OS200D12P Switch fuse
1SCA022721R3050
022721
ABB
1 Pcs.
Connectors > Fuse switch disconnector
OS
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Operating as a robust switch fuse, the 1SCA022721R3050 ABB OS200D12P Switch fuse combines mechanical circuit isolation with reliable fuse-based protection. Devices of this type are deployed in demanding electrical distribution systems to safely disconnect loads and interrupt high fault currents. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 1SCC311049M0201
- Environmental Product Declaration - EPD: 1SCC311197D0201
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- REACH Declaration: 1SCC011021D0201
- RoHS Declaration: 1SCC011020D0201
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: 74aeb806-b7f9-4886-ada3-e06ab7b3ff0d Finland
- Simplified SCIP: 7a682a82-8ae6-4303-a350-1ae29d26e74a Germany
- Toxic Substances Control Act - TSCA: 1SCC011025D0201
- Data Sheet, Technical Information: 1SCC311013C0201
- Instructions and Manuals: 1SCC311012M0219
- Mechanical Drawings: OS200D12.igs
- Degree of Protection: acc. to IEC 60529 IP20
- Pollution Degree: 3
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 1SCC311049M0201 |
| Environmental Product Declaration - EPD | 1SCC311197D0201 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SCC011021D0201 |
| RoHS Declaration | 1SCC011020D0201 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 74aeb806-b7f9-4886-ada3-e06ab7b3ff0d Finland |
| Simplified SCIP | 7a682a82-8ae6-4303-a350-1ae29d26e74a Germany |
| 7f947406-42ce-4a12-ac3c-ad5404aca31d France | |
| dfbf644b-42aa-4d9a-8fdf-90cbde8e5be4 Germany | |
| b5c6418f-526e-406b-915a-0cbfc5477d34 Sweden | |
| 7d08c901-1a70-42da-a2df-caffb2c6e844 Poland | |
| b629addb-c146-43ff-9cec-7b18efc2a9f3 Hungary | |
| 4e01ca7e-3e6c-49d4-8a99-7ba27479fa9f Portugal | |
| fcf14a5a-d3cc-49f7-8918-9440b3484305 Estonia | |
| e8fff917-a4cb-45dd-890c-2393d8b489e9 Greece | |
| beeeed93-301c-4389-93d5-536433c8da44 Norway | |
| 54859c7b-206e-46a3-9003-c3ae1f193471 Belgium | |
| 7e0c0f05-0c91-4771-85bb-54fda9f33ce1 Croatia | |
| 71adf8bb-342d-45e1-ab84-e72dfcb42d3c Czech Republic | |
| 4862bc39-ca10-431c-bde3-da53f83e5b72 Poland | |
| 92c82966-352b-49b0-a85e-d9ad29248f9f Bulgaria | |
| 2387c710-4a89-44ea-bd97-1197991fa228 Hungary | |
| 69be7dbe-e028-4fbb-afe8-96db75058798 Spain | |
| b26fb692-3ec4-455b-b761-bc52b9113d5b France | |
| 26c2a931-a094-4bc1-8855-f2195c58ef18 Germany | |
| 775494a1-438a-4981-aa02-1066ce8265f1 Denmark | |
| 20b03d4b-2306-4d7e-bd60-023d25f11ae6 Poland | |
| de233adb-23f0-40ba-b4d3-d3dc8cf7849b Italy | |
| 90f4d1ae-1aad-4f09-b09a-e01fb2dc98f7 Germany | |
| 9bcfbc43-69ad-4808-81b2-15e68fec2f94 Netherlands | |
| 2557470c-075b-4dad-8a59-ee9ff421ccce Belgium | |
| 3b96bb04-bc83-4378-8561-b6f522236eb9 Germany | |
| 2b5d9ac9-fb3d-42e1-b9f3-72a424f375d0 Sweden | |
| Toxic Substances Control Act - TSCA | 1SCC011025D0201 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SCC311013C0201 |
| Instructions and Manuals | 1SCC311012M0219 |
| Mechanical Drawings | OS200D12.igs |
| Environmental Product Declaration - EPD | 1SCC311197D0201 |
| Environmental | |
| Degree of Protection | acc. to IEC 60529 IP20 |
| Pollution Degree | 3 |
| Ordering | |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Country or Territory of Origin | Finland |
| Dimensions | |
| Product Net Width | 177 mm |
| Product Net Height | 199 mm |
| Product Net Depth / Length | 149 mm |
| Product Net Weight | 3.1 kg |
| 6.7 lb | |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 230 mm |
| 9.1 in | |
| Package Level 1 Depth / Length | 270 mm |
| 10.6 in | |
| Package Level 1 Height | 170 mm |
| 6.7 in | |
| Package Level 1 Gross Weight | 3.3 kg |
| 7.4 lb | |
| Package Level 1 EAN | 6417019231709 |
| Technical | |
| Conventional Free-air Thermal Current (Ith) | Θ = 40 °C 200 A |
| Conventional Thermal Current (Ithe) | Fully Enclosed 200 A |
| Degree of Protection | acc. to IEC 60529 IP20 |
| Fuse Size | NH0 |
| Fuse System | DIN |
| Handle Type | Pistol handle |
| Mounting Type | Base mounting |
| Number of Poles | 3P |
| Operating Mode | Front |
| Pollution Degree | 3 |
| Position of Line Terminals | Top In - Bottom Out, Bottom In - Top Out |
| Power Loss | at Rated Operating Conditions per Pole 8 W |
| Rated Conditional Short-Circuit Current (Inc) | (500 V) 100 kA |
| (690 V) 80 kA | |
| Rated Current (In) | Main Circuit 200 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current AC-21A (Ie) | (500 V) 200 A |
| (690 V) 200 A | |
| Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 200 A |
| (500 V) 200 A | |
| (690 V) 200 A | |
| Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 200 A |
| (500 V) 200 A | |
| (690 V) 200 A | |
| Rated Operational Power AC-23A (Pe) | (220 ... 240 V) 60 kW |
| (400 V) 110 kW | |
| (415 V) 110 kW | |
| (500 V) 132 kW | |
| (690 V) 200 kW | |
| Rated Operational Voltage | Main Circuit 690 V AC |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 8 kiloampere rms |
| Standards | IEC 60947-3 |
| Switches Operating Mechanism | 12 (Between the Poles) |
| Terminal Type | Lug terminals |
| Terminal Width | 20 mm |
| Tightening Torque | 15 ... 22 N·m |
| Technical UL/CSA | |
| Tightening Torque | 15 ... 22 N·m |
| Certificates and Declarations | |
| A2L Certificate – IEC | 1SCC311209D0201 |
| ATEX Certificate | No certification needed |
| CCC Certificate | CCC OS200-250 2016 |
| Declaration of Conformity - CE | 1SCC311091D2704 |
| DNV GL Certificate | 1SCC311123D0203 |
| UL Certificate | No certification needed |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 9 | EC001040 - Fuse switch disconnector |
| ETIM 10 | EC001040 - Fuse switch disconnector |
| UNSPSC | 39122233 |
| IDEA Granular Category Code (IGCC) | 5291 >> Fuse switch disconnector |
| eClass | V11.1 : 27371401 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| E-Number (Finland) | 3661130 |
| E-Number (Norway) | 1682602 |