ABB NF40E-41 NF40E-41 1SBH137001R4140 ABB NF40E-41 24-60V50/60HZ Contactor Relay View larger
Images are for illustrative purposes only. Please refer to data sheet for details

NF40E-41 1SBH137001R4140 ABB NF40E-41 24-60V50/60HZ Contactor Relay

NF40E-41

1SBH137001R4140

ABB

1 Pcs.

NF40E-41 24-60V50/60HZ Contactor Relay NF40E-41 CONT. 4NC BOB 24-60VAC RELAY

Automation > Contactor relay
AF contactors to 38 A

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Abb NF40E-41 contactor relay delivers dependable auxiliary switching performance for heavy industrial control panels requiring multiple normally closed feedback paths. Engineers specify these units to govern machine interlocks and transmit reliable low-voltage control signals throughout automated production lines. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Number of Auxiliary Contacts NO: 4
  • Number of Auxiliary Contacts NC: 0
  • Standards: IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14
  • Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
  • Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
  • Conventional Free-air Thermal Current (I th ): acc. to IEC 60947-5-1, q = 40 °C 16 A
  • Rated Operational Current AC-15 (I e ): (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
  • Rated Short-time Withstand Current (I cw ): for 0.1 s 140 A for 1 s 100 A
  • Maximum Electrical Switching Frequency: AC-15 1200 cycles per hour DC-13 900 cycles per hour
  • Rated Insulation Voltage (U i ): acc. to UL/CSA 600 V acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
  • Rated Impulse Withstand Voltage (U imp ): 6 kV
  • Maximum Mechanical Switching Frequency: 6000 cycles per hour
  • Rated Control Circuit Voltage (U c ): 50 Hz 24 ... 60 V 60 Hz 24 ... 60 V
  • Wire Stripping Length: Auxiliary Circuit 10 mm Control Circuit 10 mm
  • Terminal Type: Screw Terminals
  • Maximum Operating Altitude Permissible: 3000 m

More info

▲

NF contactor relays are used for switching auxiliary and control circuits. NF contactor relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz. NF contactor relays can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. NF contactor relays have built-in surge protection and do not require additional surge suppressors. - Poles: 4-pole contactor relays - Control Circuit: AC operated - Accessories: a wide range of Accessories is available.

Ordering

  • EAN:
    3471523100008
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85369085

Dimensions

  • Product Net Width:
    45mm
  • Product Net Depth:
    77mm
  • Product Net Height:
    86mm
  • Product Net Weight:
    0.270kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    87 mm
  • Package Level 1 Length:
    79 mm
  • Package Level 1 Height:
    47 mm
  • Package Level 1 Gross Weight:
    0.27 kg
  • Package Level 1 EAN:
    3471523100008
  • Package Level 2 Width:
    250 mm
  • Package Level 2 Length:
    300 mm
  • Package Level 2 Height:
    315 mm

Technical

  • Number of Auxiliary Contacts NO:
    4
  • Number of Auxiliary Contacts NC:
    0
  • Standards:
    IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14
  • Rated Operational Voltage:
    Auxiliary Circuit 690 V
    Main Circuit 690 V
  • Rated Frequency (f):
    Auxiliary Circuit 50 / 60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-5-1, q = 40 °C 16 A
  • Rated Operational Current AC-15 (Ie):
    (220 / 240 V) 4 A
    (24 / 127 V) 6 A
    (400 / 440 V) 3 A
    (500 V) 2 A
    (690 V) 2 A
  • Rated Short-time Withstand Current (Icw):
    for 0.1 s 140 A
    for 1 s 100 A
  • Maximum Electrical Switching Frequency:
    AC-15 1200 cycles per hour
    DC-13 900 cycles per hour
  • Rated Operational Current DC-13 (Ie):
    (110 V) 0.55 A / 60 W
    (125 V) 0.55 A / 69 W
    (220 V) 0.27 A / 60 W
    (24 V) 6 A / 144 W
    (250 V) 0.27 A / 68 W
    (400 V) 0.15 A / 60 W
    (48 V) 2.8 A / 134 W
    (500 V) 0.13 A / 65 W
    (600 V) 0.1 A / 60 W
    (72 V) 1 A / 72 W
  • Rated Insulation Voltage (Ui):
    acc. to UL/CSA 600 V
    acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
  • Rated Impulse Withstand Voltage (Uimp):
    6 kV
  • Maximum Mechanical Switching Frequency:
    6000 cycles per hour
  • Rated Control Circuit Voltage (Uc):
    50 Hz 24 ... 60 V
    60 Hz 24 ... 60 V
  • Operate Time:
    Between Coil De-energization and NC Contact Closing 13...98 ms
    Between Coil De-energization and NO Contact Opening 11...95 ms
    Between Coil Energization and NC Contact Opening 38...90 ms
    Between Coil Energization and NO Contact Closing 40...95 ms
  • Connecting Capacity-Auxiliary Circuit:
    Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
    Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
    Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
    Rigid 1/2x 1...2.5 mm²
  • Connecting Capacity-Control Circuit:
    Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
    Flexible with Insulated Ferrule 1x 0.75...2.5 mm²
    Flexible with Insulated Ferrule 2x 0.75...1.5 mm²
    Rigid 1/2x 1...2.5 mm²
  • Wire Stripping Length:
    Auxiliary Circuit 10 mm
    Control Circuit 10 mm
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Terminal Type:
    Screw Terminals

Environmental

  • Ambient Air Temperature:
    Close to Contactor for Storage -60...+80 °C
    Near Contactor for Operation in Free Air -40 ... +70 °C
  • Maximum Operating Altitude Permissible:
    3000 m
  • Resistance to Shock acc. to IEC 60068-2-27:
    Closed, Shock Direction: B1 25 g
    Open, Shock Direction: B1 5 g
    Shock Direction: A 30 g
    Shock Direction: B2 15 g
    Shock Direction: C1 25 g
    Shock Direction: C2 25 g
  • Resistance to Vibrations acc. to IEC 60068-2-6:
    5...300 Hz 4 g closed position / 2 g open position
  • RoHS Status:
    Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1

Technical UL/CSA

  • Tightening Torque UL/CSA:
    Auxiliary Circuit 11 in·lb
    Control Circuit 11 in·lb

Certificates and Declarations (Document Number)

Classifications

  • ETIM 5:
    EC000196 - Contactor relay
  • UNSPSC:
    39121500

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.