View larger
NF40E-41 1SBH137001R4140 ABB NF40E-41 24-60V50/60HZ Contactor Relay
NF40E-41
1SBH137001R4140
ABB
1 Pcs.
Automation > Contactor relay
AF contactors to 38 A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb NF40E-41 contactor relay delivers dependable auxiliary switching performance for heavy industrial control panels requiring multiple normally closed feedback paths. Engineers specify these units to govern machine interlocks and transmit reliable low-voltage control signals throughout automated production lines. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of Auxiliary Contacts NO: 4
- Number of Auxiliary Contacts NC: 0
- Standards: IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14
- Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
- Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (I th ): acc. to IEC 60947-5-1, q = 40 °C 16 A
- Rated Operational Current AC-15 (I e ): (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Short-time Withstand Current (I cw ): for 0.1 s 140 A for 1 s 100 A
- Maximum Electrical Switching Frequency: AC-15 1200 cycles per hour DC-13 900 cycles per hour
- Rated Insulation Voltage (U i ): acc. to UL/CSA 600 V acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
- Rated Impulse Withstand Voltage (U imp ): 6 kV
- Maximum Mechanical Switching Frequency: 6000 cycles per hour
- Rated Control Circuit Voltage (U c ): 50 Hz 24 ... 60 V 60 Hz 24 ... 60 V
- Wire Stripping Length: Auxiliary Circuit 10 mm Control Circuit 10 mm
- Terminal Type: Screw Terminals
- Maximum Operating Altitude Permissible: 3000 m
More info
▲NF contactor relays are used for switching auxiliary and control circuits. NF contactor relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz. NF contactor relays can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. NF contactor relays have built-in surge protection and do not require additional surge suppressors. - Poles: 4-pole contactor relays - Control Circuit: AC operated - Accessories: a wide range of Accessories is available.
Ordering
- EAN:
- 3471523100008
- Minimum Order Quantity:
- 1 piece
- Customs Tariff Number:
- 85369085
Dimensions
- Product Net Width:
- 45mm
- Product Net Depth:
- 77mm
- Product Net Height:
- 86mm
- Product Net Weight:
- 0.270kg
Container Information
- Package Level 1 Units:
- 1 piece
- Package Level 1 Width:
- 87 mm
- Package Level 1 Length:
- 79 mm
- Package Level 1 Height:
- 47 mm
- Package Level 1 Gross Weight:
- 0.27 kg
- Package Level 1 EAN:
- 3471523100008
- Package Level 2 Width:
- 250 mm
- Package Level 2 Length:
- 300 mm
- Package Level 2 Height:
- 315 mm
Technical
- Number of Auxiliary Contacts NO:
- 4
- Number of Auxiliary Contacts NC:
- 0
- Standards:
- IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14
- Rated Operational Voltage:
- Auxiliary Circuit 690 V
Main Circuit 690 V
- Rated Frequency (f):
- Auxiliary Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-5-1, q = 40 °C 16 A
- Rated Operational Current AC-15 (Ie):
- (220 / 240 V) 4 A
(24 / 127 V) 6 A
(400 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
- Rated Short-time Withstand Current (Icw):
- for 0.1 s 140 A
for 1 s 100 A
- Maximum Electrical Switching Frequency:
- AC-15 1200 cycles per hour
DC-13 900 cycles per hour
- Rated Operational Current DC-13 (Ie):
- (110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(24 V) 6 A / 144 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(48 V) 2.8 A / 134 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
(72 V) 1 A / 72 W
- Rated Insulation Voltage (Ui):
- acc. to UL/CSA 600 V
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
- Rated Impulse Withstand Voltage (Uimp):
- 6 kV
- Maximum Mechanical Switching Frequency:
- 6000 cycles per hour
- Rated Control Circuit Voltage (Uc):
- 50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
- Operate Time:
- Between Coil De-energization and NC Contact Closing 13...98 ms
Between Coil De-energization and NO Contact Opening 11...95 ms
Between Coil Energization and NC Contact Opening 38...90 ms
Between Coil Energization and NO Contact Closing 40...95 ms
- Connecting Capacity-Auxiliary Circuit:
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 1...2.5 mm²
- Connecting Capacity-Control Circuit:
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75...2.5 mm²
Flexible with Insulated Ferrule 2x 0.75...1.5 mm²
Rigid 1/2x 1...2.5 mm²
- Wire Stripping Length:
- Auxiliary Circuit 10 mm
Control Circuit 10 mm
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
- Terminal Type:
- Screw Terminals
Environmental
- Ambient Air Temperature:
- Close to Contactor for Storage -60...+80 °C
Near Contactor for Operation in Free Air -40 ... +70 °C
- Maximum Operating Altitude Permissible:
- 3000 m
- Resistance to Shock acc. to IEC 60068-2-27:
- Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
- Resistance to Vibrations acc. to IEC 60068-2-6:
- 5...300 Hz 4 g closed position / 2 g open position
- RoHS Status:
- Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1
Technical UL/CSA
- Tightening Torque UL/CSA:
- Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Certificates and Declarations (Document Number)
- ABS Certificate:
- ABS_15-GE1349500-PDA_90682247
- CB Certificate:
- CB_SE_70920A1M2
- CCC Certificate:
- CCC_2011010303465426
- cUL Certificate:
- UL_20091127-E252354-2-1
- Declaration of Conformity - CE:
- 1SBD250166C2000
- DNV Certificate:
- DNV_E11683
- EAC Certificate:
- EAC_RU C-FR ME77 B01006
- GL Certificate:
- GL_3786612HH
- GOST Certificate:
- GOST_POCCFR.ME77.B06804.pdf
- LR Certificate:
- LRS_C1400038
- RINA Certificate:
- RINA_ELE084013XG
- RMRS Certificate:
- RMRS_1300132124
- RoHS Information:
- 1SBD251014E1000
Classifications
- ETIM 5:
- EC000196 - Contactor relay
- UNSPSC:
- 39121500