Abb NF22E-41 contactor relay handles auxiliary switching duties in complex industrial automation logic circuits, reliably routing control signals to larger actuators. Control system builders integrate these versatile electromechanical relays into starter panels to expand contact capacity and manage interlocking tasks. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of Auxiliary Contacts NO: 2
- Number of Auxiliary Contacts NC: 2
- Standards: IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14
- Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
- Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (I th ): acc. to IEC 60947-5-1, q = 40 °C 16 A
- Rated Operational Current AC-15 (I e ): (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Short-time Withstand Current (I cw ): for 0.1 s 140 A for 1 s 100 A
- Maximum Electrical Switching Frequency: AC-15 1200 cycles per hour DC-13 900 cycles per hour
- Rated Insulation Voltage (U i ): acc. to UL/CSA 600 V acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
- Rated Impulse Withstand Voltage (U imp ): 6 kV
- Maximum Mechanical Switching Frequency: 6000 cycles per hour
- Rated Control Circuit Voltage (U c ): 50 Hz 24 ... 60 V 60 Hz 24 ... 60 V
- Wire Stripping Length: Auxiliary Circuit 10 mm Control Circuit 10 mm
- Terminal Type: Screw Terminals
- Maximum Operating Altitude Permissible: 3000 m
More info
▲NF contactor relays are used for switching auxiliary and control circuits. NF contactor relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz. NF contactor relays can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. NF contactor relays have built-in surge protection and do not require additional surge suppressors. - Poles: 4-pole contactor relays (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and including the "Mechanically Linked" symbol on the contactor relay side) - Control Circuit: AC operated - Accessories: a wide range of Accessories is available.
Ordering
- EAN:
- 3471523100107
- Minimum Order Quantity:
- 1 piece
- Customs Tariff Number:
- 85369085
Dimensions
- Product Net Width:
- 45mm
- Product Net Depth:
- 77mm
- Product Net Height:
- 86mm
- Product Net Weight:
- 0.270kg
Container Information
- Package Level 1 Units:
- 1 piece
- Package Level 1 Width:
- 87 mm
- Package Level 1 Length:
- 79 mm
- Package Level 1 Height:
- 47 mm
- Package Level 1 Gross Weight:
- 0.27 kg
- Package Level 1 EAN:
- 3471523100107
- Package Level 2 Width:
- 250 mm
- Package Level 2 Length:
- 300 mm
- Package Level 2 Height:
- 315 mm
Technical
- Number of Auxiliary Contacts NO:
- 2
- Number of Auxiliary Contacts NC:
- 2
- Standards:
- IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14
- Rated Operational Voltage:
- Auxiliary Circuit 690 V
Main Circuit 690 V
- Rated Frequency (f):
- Auxiliary Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-5-1, q = 40 °C 16 A
- Rated Operational Current AC-15 (Ie):
- (220 / 240 V) 4 A
(24 / 127 V) 6 A
(400 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
- Rated Short-time Withstand Current (Icw):
- for 0.1 s 140 A
for 1 s 100 A
- Maximum Electrical Switching Frequency:
- AC-15 1200 cycles per hour
DC-13 900 cycles per hour
- Rated Operational Current DC-13 (Ie):
- (110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(24 V) 6 A / 144 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(48 V) 2.8 A / 134 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
(72 V) 1 A / 72 W
- Rated Insulation Voltage (Ui):
- acc. to UL/CSA 600 V
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
- Rated Impulse Withstand Voltage (Uimp):
- 6 kV
- Maximum Mechanical Switching Frequency:
- 6000 cycles per hour
- Rated Control Circuit Voltage (Uc):
- 50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
- Operate Time:
- Between Coil De-energization and NC Contact Closing 13...98 ms
Between Coil De-energization and NO Contact Opening 11...95 ms
Between Coil Energization and NC Contact Opening 38...90 ms
Between Coil Energization and NO Contact Closing 40...95 ms
- Connecting Capacity-Auxiliary Circuit:
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 1...2.5 mm²
- Connecting Capacity-Control Circuit:
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75...2.5 mm²
Flexible with Insulated Ferrule 2x 0.75...1.5 mm²
Rigid 1/2x 1...2.5 mm²
- Wire Stripping Length:
- Auxiliary Circuit 10 mm
Control Circuit 10 mm
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
- Terminal Type:
- Screw Terminals
Environmental
- Ambient Air Temperature:
- Close to Contactor for Storage -60...+80 °C
Near Contactor for Operation in Free Air -40 ... +70 °C
- Maximum Operating Altitude Permissible:
- 3000 m
- Resistance to Shock acc. to IEC 60068-2-27:
- Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
- Resistance to Vibrations acc. to IEC 60068-2-6:
- 5...300 Hz 4 g closed position / 2 g open position
- RoHS Status:
- Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1
Technical UL/CSA
- Tightening Torque UL/CSA:
- Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Certificates and Declarations (Document Number)
- ABS Certificate:
- ABS_15-GE1349500-PDA_90682247
- CB Certificate:
- CB_SE_70920A1M2
- CCC Certificate:
- CCC_2011010303465426
- cUL Certificate:
- UL_20091127-E252354-2-1
- Declaration of Conformity - CE:
- 1SBD250166C2000
- DNV Certificate:
- DNV_E11683
- EAC Certificate:
- EAC_RU C-FR ME77 B01006
- GL Certificate:
- GL_3786612HH
- GOST Certificate:
- GOST_POCCFR.ME77.B06804.pdf
- LR Certificate:
- LRS_C1400038
- RINA Certificate:
- RINA_ELE084013XG
- RMRS Certificate:
- RMRS_1300132124
- RoHS Information:
- 1SBD251014E1000
Classifications
- ETIM 5:
- EC000196 - Contactor relay
- UNSPSC:
- 39121500