View larger
1SAM340000R1011 ABB MS132-16T Circuit Breaker for Primary Transformer Protection
1SAM340000R1011
340000
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Mx116 and Mx132
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Offering specialized circuit protection, the 1SAM340000R1011 ABB MS132-16T Circuit Breaker for Primary Transformer Protection safeguards electrical transformers against overcurrents and short-circuit faults. These protective devices are commonly installed in control panels to isolate transformer primaries and prevent downstream equipment damage. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362010
- Data Sheet, Technical Information: 2CDC131058D0201
- Instructions and Manuals: 2CDC131057M6801
- Instructions and Manuals (Part 2): 2CDC131060M0202
- Time-Current Characteristic Curve: 1SAM300535F0011
- I²t Characteristic: 1SAM300517F0001
- Cut-off Current Characteristic: 1SAM300518F0001
- CAD Dimensional Drawing: 2CDC001079B0201
- Dimension Diagram: 1SAM300402F0002
- Product Net Width: 45 mm
- Product Net Height: 97.8 mm
- Product Net Depth / Length: 86.05 mm
- Product Net Weight: 0.31 kg
- Rated Service Short-Circuit Breaking Capacity (I cs ): (230 V AC) 100 kA
- Rated Ultimate Short-Circuit Breaking Capacity (I cu ): (400 V AC) 100 kA
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362010 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC131058D0201 |
| Instructions and Manuals | 2CDC131057M6801 |
| Instructions and Manuals (Part 2) | 2CDC131060M0202 |
| Time-Current Characteristic Curve | 1SAM300535F0011 |
| I²t Characteristic | 1SAM300517F0001 |
| Cut-off Current Characteristic | 1SAM300518F0001 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimension Diagram | 1SAM300402F0002 |
| Dimensions | |
| Product Net Width | 45 mm |
| Product Net Height | 97.8 mm |
| Product Net Depth / Length | 86.05 mm |
| Product Net Weight | 0.31 kg |
| Technical | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 100 kA |
| (400 V AC) 100 kA | |
| (440 V AC) 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 320 A |
| Setting Range | 10 ... 16 A |
| Rated Operational Voltage | Main Circuit 690 V AC |
| Rated Operational Current (Ie) | 16 A |
| Rated Frequency (f) | Main Circuit 50 Hz |
| Main Circuit 60 Hz | |
| Operating Frequency (fsw) | 0 ... 400 Hz |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
| Rated Insulation Voltage (Ui) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 0.9 ... 2.3 W |
| Number of Poles | 3P |
| Conventional Free-air Thermal Current (Ith) | Main Circuit 16 A |
| Degree of Protection | Housing IP20 |
| Main Circuit Terminals IP10 | |
| Pollution Degree | 3 |
| Electrical Durability | 50000 cycle |
| Mechanical Durability | Nr. Operations 100000 cycle |
| Terminal Type | Screw Terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 6 mm² |
| Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm² | |
| Flexible 1/2x 1 ... 2.5 mm² | |
| Flexible 1/2x 2.5 ... 6 mm² | |
| Rigid 1/2x 1 ... 2.5 mm² | |
| Rigid 1/2x 2.5 ... 6 mm² | |
| Tightening Torque | Main Circuit 2 N·m |
| Wire Stripping Length | Main Circuit 10 mm |
| Recommended Screw Driver | M4 |
| Pozidriv 2 | |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Minimum Mounting Distance | Electrical Conductive Board, Vertical 75 mm |
| Other Device Same Type, Horizontal 9 mm | |
| Other Device Same Type, Vertical 150 mm | |
| Actuator Type | Rotary Handle |
| Contact Position Indication | ON / OFF / TRIP |
| Standards | IEC/EN 60947-1 |
| IEC/EN 60947-2 | |
| IEC/EN 60947-4-1 | |
| IEC 60335-2-40 A2L | |
| Technical UL/CSA | |
| Short-Circuit Current Rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA |
| Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 1 Hp |
| (220 ... 240 V AC) Single Phase 2 Hp | |
| Full Load Amps Motor Use | (120 V AC) Single Phase 16 A |
| (220 ... 240 V AC) Single Phase 12 A | |
| Locked Rotor Amps | (120 V AC) Single Phase 96 A |
| (220 ... 240 V AC) Single Phase 96 A | |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-8 AWG |
| Stranded 1/2x 16-8 AWG | |
| Tightening Torque UL/CSA | Main Circuit 16 in·lb |
| Environmental | |
| Ambient Air Temperature | Around the Enclosure 0 ... +40 °C |
| Operation -25 ... +70 °C | |
| Operation Compensated -25 ... +60 °C | |
| Storage -50 ... +80 °C | |
| Ambient Air Temperature Compensation | Yes |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g |
| Resistance to Vibrations | 5g 3 ... 150 Hz |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SAA963005-4502 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006539 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| End Of Life Disassembling Instructions | 1SAC200332H0001 |
| Environmental Product Declaration - EPD | 1SAC200360H0001 |
| 1SAC200385H0001 | |
| Certificates and Declarations | |
| A2L Certificate – IEC | 1SAA963000-4601 |
| CB Certificate | 1SAA963002-2002 |
| 1SAA963007-2002 | |
| CCC Certificate | 2024010307654702 |
| 2024010307658958 | |
| CQC Certificate | CQC2010010307387700 |
| CQC2019010307243864 | |
| Cut-off Current Characteristic | 1SAM300518F0001 |
| Declaration of Conformity - CCC | 2020980307003526 |
| 2020980307003041 | |
| Declaration of Conformity - CE | 1SAD101100-3404 |
| Declaration of Conformity - UKCA | 1SAD201100-3404 |
| KC Certificate | 1SAA963002-1502 |
| RMRS Certificate | 1SAA918000-0704 |
| UL Certificate | E137861-20090225 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 92 mm |
| Package Level 1 Depth / Length | 102 mm |
| Package Level 1 Height | 50 mm |
| Package Level 1 Gross Weight | 0.325 kg |
| Package Level 1 EAN | 4013614485022 |
| Package Level 2 Units | carton 40 piece |
| Package Level 2 Width | 280 mm |
| Package Level 2 Depth / Length | 395 mm |
| Package Level 2 Height | 210 mm |
| Package Level 2 Gross Weight | 13.386 kg |
| Package Level 2 EAN | 4013614487224 |
| External Classifications and Standards | |
| Object Classification Code | F |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| eClass | V11.0 : 27370409 |
| UNSPSC | 39121601 |
| IDEA Granular Category Code (IGCC) | 4864 >> Enclosed 3 Pole Circuit Breakers |
| E-Number (Finland) | 3707273 |
| E-Number (Norway) | 4364110 |