View larger
1SAM350000R1011
350000
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362010 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC131021D0202 |
| Instructions and Manuals | 2CDC131022M6802 |
| Instructions and Manuals (Part 2) | 2CDC131060M0202 |
| Ex Operating Instructions | 2CDC131063M6801 |
| Time-Current Characteristic Curve | 1SAM300505F0011 |
| I²t Characteristic | 1SAM300507F0001 |
| 1SAM300507F0003 | |
| Cut-off Current Characteristic | 1SAM300508F0001 |
| 1SAM300508F0003 | |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimension Diagram | 1SAM300402F0002 |
| Dimensions | |
| Product Net Width | 45 mm |
| Product Net Height | 97.8 mm |
| Product Net Depth / Length | 86.55 mm |
| Product Net Weight | 0.31 kg |
| Technical | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 100 kA |
| (250 V DC) 3 Poles in Series 10 kA | |
| (400 V AC) 100 kA | |
| (440 V AC) 30 kA | |
| (500 V AC) 20 kA | |
| (690 V AC) 3 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 100 kA |
| (400 V AC) 100 kA | |
| (440 V AC) 30 kA | |
| (500 V AC) 20 kA | |
| (690 V AC) 3 kA | |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 240 A |
| Setting Range | 10 ... 16 A |
| Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 7.5 kW |
| Rated Operational Power AC-3e (Pe) | (400 V) Three Phase 7.5 kW |
| Rated Operational Voltage | Main Circuit 690 V AC |
| Main Circuit 250 V DC | |
| Rated Operational Current (Ie) | 16 A |
| Rated Operational Current AC-3 (Ie) | 16 A |
| Rated Operational Current AC-3e (Ie) | 16 A |
| Rated Operational Current DC-5 (Ie) | 16 A |
| Rated Frequency (f) | Main Circuit 50 Hz |
| Main Circuit 60 Hz | |
| Operating Frequency (fsw) | 0 ... 400 Hz |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
| Rated Insulation Voltage (Ui) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 1.1 ... 2.8 W |
| Number of Poles | 3P |
| Conventional Free-air Thermal Current (Ith) | Main Circuit 16 A |
| Degree of Protection | Housing IP20 |
| Main Circuit Terminals IP10 | |
| Pollution Degree | 3 |
| Electrical Durability | 50000 cycle |
| Mechanical Durability | Nr. Operations 100000 cycle |
| Terminal Type | Screw Terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 6 mm² |
| Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm² | |
| Flexible 1/2x 1 ... 2.5 mm² | |
| Flexible 1/2x 2.5 ... 6 mm² | |
| Rigid 1/2x 1 ... 2.5 mm² | |
| Rigid 1/2x 2.5 ... 6 mm² | |
| Tightening Torque | Main Circuit 2 N·m |
| Wire Stripping Length | Main Circuit 10 mm |
| Recommended Screw Driver | Pozidriv 2 |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 400 V 0 mm |
| Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm | |
| Electrical Conductive Board, Vertical 75 mm | |
| Other Device Same Type, Horizontal 0 mm | |
| Other Device Same Type, Vertical 150 mm | |
| Actuator Type | Rotary Handle |
| Contact Position Indication | ON / OFF / TRIP |
| Standards | IEC/EN 60947-1 |
| IEC/EN 60947-2 | |
| IEC/EN 60947-4-1 | |
| UL 60947-1 | |
| UL 60947-4-1 | |
| IEC 60335-2-40 A2L | |
| Remarks | UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx |
| Technical UL/CSA | |
| Short-Circuit Current Rating (SCCR) | Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kA |
| Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 3 Hp |
| (208 V AC) Three Phase 3 Hp | |
| (220 ... 240 V AC) Three Phase 5 Hp | |
| (440 ... 480 V AC) Three Phase 10 Hp | |
| (550 ... 600 V AC) Three Phase 10 Hp | |
| Full Load Amps Motor Use | (200 V AC) Three Phase 11 A |
| (208 V AC) Three Phase 10.6 A | |
| (220 ... 240 V AC) Three Phase 15.2 A | |
| (440 ... 480 V AC) Three Phase 14 A | |
| (550 ... 600 V AC) Three Phase 11 A | |
| Locked Rotor Amps | (200 V AC) Three Phase 73.6 A |
| (208 V AC) Three Phase 71 A | |
| (220 ... 240 V AC) Three Phase 92 A | |
| (440 ... 480 V AC) Three Phase 81 A | |
| (550 ... 600 V AC) Three Phase 64.8 A | |
| General Use Rating UL/CSA | (600 V AC) 16 A |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-8 AWG |
| Stranded 1/2x 16-8 AWG | |
| Tightening Torque UL/CSA | Main Circuit 18 in·lb |
| Environmental | |
| Ambient Air Temperature | Around the Enclosure 0 ... +40 °C |
| Operation -25 ... +70 °C | |
| Operation Compensated -25 ... +60 °C | |
| Storage -50 ... +80 °C | |
| Ambient Air Temperature Compensation | Yes |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g |
| Resistance to Vibrations | 5g 3 ... 150 Hz |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SAA963005-4502 |
| RoHS Declaration | 1SAA963006-4501 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006539 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| End Of Life Disassembling Instructions | 1SAC200332H0001 |
| Environmental Product Declaration - EPD | 1SAC200360H0001 |
| 1SAC200385H0001 | |
| Certificates and Declarations | |
| A2L Certificate – IEC | 1SAA963000-4601 |
| ABS Certificate | 1SAA963001-0101 |
| ATEX Certificate | 1SAA963000-3902 |
| BV Certificate | 1SAA963001-0202 |
| CB Certificate | 1SAA963002-2002 |
| 1SAA963007-2002 | |
| CCC Certificate | 2024010307654702 |
| 2024010307658958 | |
| CQC Certificate | CQC2010010307387700 |
| CQC2019010307243864 | |
| Cut-off Current Characteristic | 1SAM300508F0001 |
| 1SAM300508F0003 | |
| Declaration of Conformity - CCC | 2020980307003526 |
| 2020980307003041 | |
| Declaration of Conformity - CE | 1SAD101100-3402 |
| Declaration of Conformity - UKCA | 1SAD201100-3402 |
| DNV GL Certificate | 1SAA963001-0304 |
| EAC Certificate | 1SAA963000-2701 |
| IECEx Certificate | 1SAA963000-4001 |
| KC Certificate | 1SAA963002-1502 |
| LR Certificate | 1SAA963001-0502 |
| RINA Certificate | 1SAA963002-0802 |
| RMRS Certificate | 1SAA918000-0704 |
| UL Certificate | E137861-20090225 |
| E345003-20090225 | |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 92 mm |
| Package Level 1 Depth / Length | 102 mm |
| Package Level 1 Height | 50 mm |
| Package Level 1 Gross Weight | 0.325 kg |
| Package Level 1 EAN | 4013614400117 |
| Package Level 2 Units | carton 40 piece |
| Package Level 2 Width | 280 mm |
| Package Level 2 Depth / Length | 395 mm |
| Package Level 2 Height | 210 mm |
| Package Level 2 Gross Weight | 13.386 kg |
| Package Level 2 EAN | 4013614409011 |
| External Classifications and Standards | |
| Object Classification Code | F |
| ETIM 9 | EC000074 - Motor protection circuit-breaker |
| ETIM 10 | EC000074 - Motor protection circuit-breaker |
| eClass | V11.0 : 27370401 |
| UNSPSC | 39121521 |
| IDEA Granular Category Code (IGCC) | 4731 >> Manual Starters |
| E-Number (Finland) | 3705995 |
| E-Number (Norway) | 4364080 |
| E-Number (Sweden) | 3112127 |
| Feature Name | Feature Value |
|---|---|
| Overload release current setting (EF002336) | 10 A |
| Adjustment range undelayed short-circuit release (EF007131) | 240 A |
| With thermal overload protection (EF006233) | Yes |
| Phase failure sensitive (EF007400) | Yes |
| Switch off technique (EF007007) | Thermomagnetic |
| Rated operating voltage (EF001435) | 250 V |
| Rated permanent current Iu (EF001389) | 16 A |
| Rated operation power at AC-3, 230 V (EF007025) | 7.5 kW |
| Rated operation power at AC-3, 400 V (EF001364) | 7.5 kW |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| Type of control element (EF006976) | Rotating button |
| Device construction (EF008240) | Complete device in housing |
| With integrated auxiliary switch (EF001387) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Rated short-circuit breaking capacity Icu at 400 V, AC (EF007049) | 100 kA |
| Degree of protection (IP) (EF005474) | IP20 |
| Height (EF000040) | 97.8 mm |
| Width (EF000008) | 45 mm |
| Depth (EF000049) | 86.55 mm |