View larger
1SAM461000R1015 ABB MO165-42 Manual Motor Starter Magnetic Only
1SAM461000R1015
461000
ABB
1 Pcs.
Automation > Motor protection circuit-breaker
Mx116 and Mx132
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An 1SAM461000R1015 ABB manual motor starter is a magnetic-only protection device engineered to safeguard heavy-duty industrial machinery from short-circuit events. Control system integrators utilize these starters to provide reliable disconnecting means and fault protection within motor control centers. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362010
- Data Sheet, Technical Information: 2CDC131084D0201
- Instructions and Manuals: 2CDC131082M6801
- Instructions and Manuals (Part 2): 2CDC131060M0202
- Time-Current Characteristic Curve: 1SAM400515F0001
- I²t Characteristic: 1SAM400506F0001
- Cut-off Current Characteristic: 1SAM400507F0001
- CAD Dimensional Drawing: 2CDC001079B0201
- Dimension Diagram: 1SAM400402F0001
- Product Net Width: 55 mm
- Product Net Height: 142.65 mm
- Product Net Depth / Length: 122.1 mm
- Product Net Weight: 0.97 kg
- Rated Service Short-Circuit Breaking Capacity (I cs ): (230 V AC) 50 kA
- Rated Ultimate Short-Circuit Breaking Capacity (I cu ): (230 V AC) 50 kA
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362010 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC131084D0201 |
| Instructions and Manuals | 2CDC131082M6801 |
| Instructions and Manuals (Part 2) | 2CDC131060M0202 |
| Time-Current Characteristic Curve | 1SAM400515F0001 |
| I²t Characteristic | 1SAM400506F0001 |
| Cut-off Current Characteristic | 1SAM400507F0001 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimension Diagram | 1SAM400402F0001 |
| Dimensions | |
| Product Net Width | 55 mm |
| Product Net Height | 142.65 mm |
| Product Net Depth / Length | 122.1 mm |
| Product Net Weight | 0.97 kg |
| Technical | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 50 kA |
| (250 V DC) 3 Poles in Series 100 kA | |
| (400 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (690 V AC) 10 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 50 kA |
| (250 V DC) 100 kA | |
| (400 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 30 kA | |
| (690 V AC) 10 kA | |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 630 A |
| Setting Range | None |
| Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 22 kW |
| Rated Operational Power AC-3e (Pe) | (400 V) Three Phase 22 kW |
| Rated Operational Voltage | Main Circuit 690 V AC |
| Main Circuit 250 V DC | |
| Rated Operational Current (Ie) | 42 A |
| Rated Operational Current AC-3 (Ie) | 42 A |
| Rated Operational Current AC-3e (Ie) | 42 A |
| Rated Operational Current DC-5 (Ie) | 42 A |
| Rated Frequency (f) | Main Circuit 50 Hz |
| Main Circuit 60 Hz | |
| Operating Frequency (fsw) | 0 ... 415 Hz |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Power Loss | 5.47 W |
| Number of Poles | 3P |
| Conventional Free-air Thermal Current (Ith) | Main Circuit 42 A |
| Degree of Protection | Housing IP20 |
| Main Circuit Terminals IP10 | |
| Pollution Degree | 3 |
| Electrical Durability | 25000 cycle |
| Mechanical Durability | Nr. Operations 50000 cycle |
| Terminal Type | Screw Terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 1 ... 35 mm² |
| Flexible with Insulated Ferrule 1/2x 1 ... 35 mm² | |
| Flexible 1/2x 1 ... 35 mm² | |
| Rigid 1/2x 1 ... 4 mm² | |
| Solid 1/2x 1 ... 4 mm² | |
| Stranded 1/2x 1 ... 50 mm² | |
| Tightening Torque | Main Circuit 4 N·m |
| Wire Stripping Length | Main Circuit 16 mm |
| Recommended Screw Driver | Pozidriv 2 |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm |
| Electrical Conductive Board, Horizontal - Up to 400 V 0 mm | |
| Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm | |
| Electrical Conductive Board, Vertical 75 mm | |
| Other Device Same Type, Horizontal 0 mm | |
| Other Device Same Type, Vertical 150 mm | |
| Actuator Type | Rotary Handle |
| Contact Position Indication | ON / OFF / TRIP |
| Standards | CSA 22.2 No. 14 |
| IEC/EN 60947-1 | |
| IEC/EN 60947-2 | |
| IEC/EN 60947-4-1 | |
| UL 60947-4-1 | |
| Remarks | For overload protection of the motors, an appropriate thermal or electronic overload relays must be used |
| Technical UL/CSA | |
| Short-Circuit Current Rating (SCCR) | Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA |
| Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA | |
| Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 10 Hp |
| (208 V AC) Three Phase 10 Hp | |
| (220 ... 240 V AC) Three Phase 15 Hp | |
| (440 ... 480 V AC) Three Phase 30 Hp | |
| (550 ... 600 V AC) Three Phase 40 Hp | |
| Full Load Amps Motor Use | (200 V AC) Three Phase 32.2 A |
| (208 V AC) Three Phase 30.8 A | |
| (220 ... 240 V AC) Three Phase 42 A | |
| (440 ... 480 V AC) Three Phase 40 A | |
| (550 ... 600 V AC) Three Phase 41 A | |
| Locked Rotor Amps | (200 V AC) Three Phase 186.3 A |
| (208 V AC) Three Phase 179 A | |
| (220 ... 240 V AC) Three Phase 232 A | |
| (440 ... 480 V AC) Three Phase 218 A | |
| (550 ... 600 V AC) Three Phase 232 A | |
| General Use Rating UL/CSA | (600 V AC) 42 A |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-0 AWG |
| Stranded 1/2x 16-0 AWG | |
| Tightening Torque UL/CSA | Main Circuit 35 in·lb |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Operation Compensated -25 ... +60 °C | |
| Storage -50 ... +80 °C | |
| Ambient Air Temperature Compensation | No |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g |
| Resistance to Vibrations | Mounted on Mounting Plate: 5g 3 ... 150 Hz |
| Mounted on DIN-Rail: 4g 3 ... 150 Hz | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SAA963005-4502 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006539 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| End Of Life Disassembling Instructions | 1SAC200284H0001 |
| Environmental Product Declaration - EPD | 1SAC200253H0001 |
| Certificates and Declarations | |
| ABS Certificate | 1SAA963002-0101 |
| BV Certificate | 1SAA963002-0201 |
| CB Certificate | 1SAA918002-2002 |
| CCC Certificate | 2024010307654703 |
| CQC Certificate | CQC2015010307760141 |
| Cut-off Current Characteristic | 1SAM400507F0001 |
| Declaration of Conformity - CCC | 2020980307003042 |
| Declaration of Conformity - CE | 1SAD101100-3409 |
| Declaration of Conformity - UKCA | 1SAD201100-3409 |
| DNV GL Certificate | 1SAA963002-0301 |
| EAC Certificate | 1SAA963000-2701 |
| IECEx Certificate | 1SAA918000-4001 |
| KC Certificate | 1SAA963001-1501 |
| LR Certificate | 1SAA918001-0501 |
| RMRS Certificate | 1SAA918000-0704 |
| UL Certificate | E137861-20150206 |
| E345003-20150206 | |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 64 mm |
| Package Level 1 Depth / Length | 177 mm |
| Package Level 1 Height | 140 mm |
| Package Level 1 Gross Weight | 1.1 kg |
| Package Level 1 EAN | 4013614486166 |
| Package Level 2 Units | carton 12 piece |
| Package Level 2 Width | 330 mm |
| Package Level 2 Depth / Length | 400 mm |
| Package Level 2 Height | 320 mm |
| Package Level 2 Gross Weight | 13 kg |
| Package Level 2 EAN | 4013614504020 |
| External Classifications and Standards | |
| Object Classification Code | F |
| ETIM 9 | EC000074 - Motor protection circuit-breaker |
| ETIM 10 | EC000074 - Motor protection circuit-breaker |
| eClass | V11.0 : 27370401 |
| UNSPSC | 39121521 |
| IDEA Granular Category Code (IGCC) | 4731 >> Manual Starters |
| E-Number (Finland) | 3707295 |
| E-Number (Norway) | 4364144 |
| E-Number (Sweden) | 3110142 |