View larger
2CSS275101R0404 ABB Miniature circuit breaker SN201 2P C 40 A
2CSS275101R0404
275101
ABB
1 Pcs.
Automation > Miniature circuit breaker (MCB)
SN200
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 2CSS275101R0404 is a 2CSS275101R0404 ABB Miniature circuit breaker SN201 2P C 40 A integrated into electrical distribution systems to protect branch circuits against overcurrent and short-circuit faults. This protective device ensures automated interruption of power during electrical anomalies.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- EcoSolutions Profile: 9AKK108471A1004
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 90.63 %
- Sustainable Material Content in Packaging (wt. %): Recycled Paper - 00 %
- Extended Product Lifetime: Product Durability
- End Of Life Disassembling Instructions: 9AKK108469A7476
- Environmental Product Declaration - EPD: 9AKK108469A9820
- Dielectric Test Voltage: 50 / 60 Hz - 1 min 2 kV
- Primary Rated Impulse Withstand Voltage: 4 kV
- Rated Ultimate Short-Circuit Breaking Capacity (I cu ): (230 V) 10 kA
- Rated Service Short-Circuit Breaking Capacity (I cs ): (230 V AC) 7.5 kA
- Power Supply Connection: Arbitrary
- Contact Position Indication: Red ON / Green OFF
- Energy Limiting Class: 3
- Electrical Endurance: 10000 cycle
- Mechanical Endurance: 20000 cycle
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| EcoSolutions Profile | 9AKK108471A1004 |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 90.63 % |
| Sustainable Material Content in Packaging (wt. %) | Recycled Paper - 00 % |
| Recycled Cardboard - 79 % | |
| Extended Product Lifetime | Product Durability |
| End Of Life Disassembling Instructions | 9AKK108469A7476 |
| Environmental Product Declaration - EPD | 9AKK108469A9820 |
| Technical | |
| Dielectric Test Voltage | 50 / 60 Hz - 1 min 2 kV |
| Primary Rated Impulse Withstand Voltage | 4 kV |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V) 10 kA |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 7.5 kA |
| Power Supply Connection | Arbitrary |
| Contact Position Indication | Red ON / Green OFF |
| Energy Limiting Class | 3 |
| Electrical Endurance | 10000 cycle |
| Mechanical Endurance | 20000 cycle |
| Number of Protected Poles | 1 |
| Number of Poles | 1P+N |
| Number of Modular Spacings per DIN Rail | 1 |
| Position of Neutral Terminals | Right |
| Tightening Torque | 1.2 N·m |
| Actuator Type | Toggle |
| Screw Terminal Type | Cage Terminal |
| Accessories Available | Yes |
| Connecting Capacity | Flexible 1 … 10 mm² |
| Rigid 1 … 16 mm² | |
| Wire Stripping Length | 11 mm |
| Terminal Type | Screw Terminals |
| Electrical | |
| Tripping Characteristic | C |
| Rated Voltage (Ur) | 230 V AC |
| Rated Operational Voltage | acc. to IEC 60898-1 230 V |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 500 V |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Input Voltage Type | AC |
| Rated Current (In) | 40 A |
| Rated Short-Circuit Capacity | (230 V) 10 kA |
| Rated Frequency (f) | 50 / 60 Hz |
| Power Loss | Total 7.5 W |
| Overvoltage Category | III |
| Design | |
| Housing Material | Insulation group II, RAL 7035 |
| Material Compliance | |
| RoHS Declaration | 9AKK106713A5572 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20211115 |
| REACH Information | No data - If REACH inform is not yet available for a certain product |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Consumer |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +55 °C |
| Reference Ambient Air Temperature | 30 °C |
| Degree of Protection | IP20 |
| Pollution Degree | 2 |
| Environmental Conditions | 28 cycles |
| ;with 55 °C / 90-96 % | |
| ;and 25 °C / 95-100 % | |
| Resistance to Vibrations | 20 Cycles with Load 0.8 In: 5g or 0.35mm 5 … 150 … 5 Hz |
| Resistance to Shock acc. to IEC 60068-2-27 | 30g 2 shocks 13 ms |
| Environmental Information | refer to RoHS information |
| Dimensions | |
| Width in Number of Modular Spacings | 1 |
| Product Net Width | 18 mm |
| Product Net Height | 85 mm |
| Product Net Depth / Length | 69 mm |
| Product Net Weight | 110 g |
| Built-In Depth (t2) | 69 mm |
| Ordering | |
| Package Level 1 Units | box 6 piece |
| Package Level 1 Gross Weight | 0.684 kg |
| E-Number (Norway) | 1630689 |
| Certificates and Declarations | |
| Declaration of Conformity - CE | 9AKK106713A5572 |
| Installation | |
| Mounting Position | Any |
| Popular Downloads | |
| Data Sheet, Technical Information | 9AKK107991A8329 |
| External Classifications and Standards | |
| ETIM 9 | EC000042 - Miniature circuit breaker (MCB) |
| ETIM 10 | EC000042 - Miniature circuit breaker (MCB) |
| UNSPSC | 39121603 |
| eClass | V11.0 : 27141901 |
| Object Classification Code | F |
| Standards | IEC/EN 60898-1 |
| Certification Agency | EN |
| IEC | |