View larger
2CDS283001R0014 ABB Miniature Circuit Breaker S200P 3P C 1 ampere
2CDS283001R0014
283001
ABB
1 Pcs.
Automation > Miniature circuit breaker (MCB)
S200P
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB miniature circuit breaker S200P 3P C 1 ampere, referenced by part number 2CDS283001R0014, is a protective switching device engineered to automatically disconnect power during overloads or short-circuit conditions. These components are deployed in industrial electrical systems to maintain operational safety.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- 2CCA880100R0001: 1
- 2CCA880101R0001: 1
- 2CCA880102R0001: 1
- 2CDS200909R0001: 1
- 2CDS200909R0002: 1
- 2CDS200912R0001: 1
- 2CDS200918R0001: 1
- 2CDS200922R0001: 1
- 2CDS200936R0001: 1
- 2CDS200936R0002: 1
- 2CDS200936R0003: 1
- 2CDS200946R0001: 1
- 2CDS200946R0002: 1
- 2CDS200946R0003: 1
- 2CDS200970R0001: 1
- 2CDS200970R0002: 1
More info
▲Accessories
| Identifier | Qty | Unit Of Measure | Type | Description |
|---|---|---|---|---|
| 2CCA880100R0001 | 1 | piece | CMS-100PS | CMS-100PS Sensor |
| 2CCA880101R0001 | 1 | piece | CMS-101PS | CMS-101PS Sensor |
| 2CCA880102R0001 | 1 | piece | CMS-102PS | CMS-102PS Sensor |
| 2CDS200909R0001 | 1 | piece | S2C-A1 | S2C-A1 - Shunt Trip |
| 2CDS200909R0002 | 1 | piece | S2C-A2 | S2C-A2 - Shunt Trip |
| 2CDS200912R0001 | 1 | piece | S2C-H6R | S2C-H6R - Auxiliary Contact |
| 2CDS200918R0001 | 1 | piece | S2C-NT | S2C-NT - Hand Operated Neutral |
| 2CDS200922R0001 | 1 | piece | S2C-S/H6R | S2C-S/H6R - Signal / Auxiliary Contact |
| 2CDS200936R0001 | 1 | piece | S2C-H11L | S2C-H11L - Auxiliary Contact |
| 2CDS200936R0002 | 1 | piece | S2C-H20L | S2C-H20L - Auxiliary Contact |
| 2CDS200936R0003 | 1 | piece | S2C-H02L | S2C-H02L - Auxiliary Contact |
| 2CDS200946R0001 | 1 | piece | S2C-H6-11R | S2C-H6-11R - Auxiliary Contact |
| 2CDS200946R0002 | 1 | piece | S2C-H6-20R | S2C-H6-20R - Auxiliary Contact |
| 2CDS200946R0003 | 1 | piece | S2C-H6-02R | S2C-H6-02R - Auxiliary Contact |
| 2CDS200970R0001 | 1 | piece | S2C-H01 | S2C-H01 - Auxiliary Contact |
| 2CDS200970R0002 | 1 | piece | S2C-H10 | S2C-H10 - Auxiliary Contact |
| 2CSS200911R0001 | 1 | piece | S2C-UA 12 DC | S2C-UA 12 DC - Undervoltage release |
| 2CSS200911R0002 | 1 | piece | S2C-UA 24 AC | S2C-UA 24 AC - Undervoltage release |
| 2CSS200911R0003 | 1 | piece | S2C-UA 48 AC | S2C-UA 48 AC - Undervoltage release |
| 2CSS200911R0004 | 1 | piece | S2C-UA 110 AC | S2C-UA 110 AC - Undervoltage release |
| 2CSS200911R0005 | 1 | piece | S2C-UA 230 AC | S2C-UA 230 AC - Undervoltage release |
| 2CSS200911R0006 | 1 | piece | S2C-UA 400 AC | S2C-UA 400 AC - Undervoltage release |
| 2CSS200911R0007 | 1 | piece | S2C-UA 24 DC | S2C-UA 24 DC - Undervoltage release |
| 2CSS200911R0008 | 1 | piece | S2C-UA 48 DC | S2C-UA 48 DC - Undervoltage release |
| 2CSS200911R0009 | 1 | piece | S2C-UA 110 DC | S2C-UA 110 DC - Undervoltage release |
| 2CSS200911R0010 | 1 | piece | S2C-UA 230 DC | S2C-UA 230 DC - Undervoltage release |
| 2CSS200998R0001 | 1 | piece | S2C-BP | S2C-BP - Mechanical tripping device |
| 2CSS200999R0001 | 1 | piece | S2C-EST | S2C-EST - Plug-in base |
| 2CSS201997R0013 | 1 | piece | S2C-CM1 | S2C-CM1 - Motor operating device |
| 2CSS203997R0013 | 1 | piece | S2C-CM2/3 | S2C-CM2/3 - Motor operating device |
| 2CSS204997R0013 | 1 | piece | S2C-CM4 | S2C-CM4 - Motor operating device |
| GHS2001901R0003 | 1 | piece | S2C-DH | S2C-DH - Mechanical Accessories |
Ordering
| Minimum Order Quantity: | 1 piece |
| Customs Tariff Number: | 85362010 |
Popular Downloads
| Data Sheet, Technical Information: | 9AKK106930A8017 |
| Instructions and Manuals: | 2CSC400002D0208 |
Dimensions
| Product Net Width: | 52.5 mm |
| Product Net Depth / Length: | 69 mm |
| Product Net Height: | 88 mm |
| Product Net Weight: | 0.42 kg |
Technical
| Standards: | IEC/EN 60898-1 IEC/EN 60947-2 UL 1077 CSA 22.2 No. 235 |
| Number of Poles: | 3 |
| Tripping Characteristic: | C |
| Rated Current (In): | 1 A |
| Rated Operational Voltage: | acc. to IEC 60898-1 400 V AC acc. to IEC 60947-2 400 V AC |
| Power Loss: | 4.2 W at Rated Operating Conditions per Pole 1.4 W |
| Rated Insulation Voltage (Ui): | acc. to IEC/EN 60664-1 440 V |
| Operational Voltage: | Maximum (Incl. Tolerance) 440 V AC Maximum 440 V AC Minimum 12 V AC Minimum 12 V DC |
| Rated Frequency (f): | 50 Hz 60 Hz |
| Rated Short-Circuit Capacity (Icn): | (400 V AC) 25 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu): | (400 V AC) 25 kA |
| Rated Service Short-Circuit Breaking Capacity (Ics): | (400 V AC) 12.5 kA |
| Energy Limiting Class: | 3 |
| Overvoltage Category: | III |
| Pollution Degree: | 3 |
| Rated Impulse Withstand Voltage (Uimp): | 4 kV (6.2 kV @ sea level) (5.0 kV @ 2000 m) |
| Dielectric Test Voltage: | 50 / 60 Hz, 1 min: 2 kV |
| Housing Material: | Insulation Group II, RAL 7035 |
| Actuator Type: | Insulation group II, black, sealable |
| Contact Position Indication: | Red ON / Green OFF |
| Degree of Protection: | IP20 |
| Remarks: | IP40 in enclosure with cover |
| Electrical Endurance: | 20000 AC cycle |
| Mechanical Endurance (Nendu): | 20000 cycle |
| Terminal Type: | Screw Terminals |
| Screw Terminal Type: | Failsafe Bi-directional Cylinder-lift Terminal |
| Connecting Capacity: | Busbar 10 / 10 mm² Flexible with Ferrule 0.75 ... 16 mm² Flexible 0.75 ... 16 mm² Rigid 0.75 ... 25 mm² Stranded 0.75 ... 25 mm² |
| Tightening Torque: | 2.8 N·m |
| Recommended Screw Driver: | Pozidriv 2 |
| Mounting on DIN Rail: | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting Position: | Any |
Environmental
| Ambient Air Temperature: | Operation -25 ... +55 °C Storage -40 ... +70 °C |
| Resistance to Shock acc. to IEC 60068-2-27: | 25g / 2 shocks / 13 ms |
| Resistance to Vibrations acc. to IEC 60068-2-6: | 5g, 20 cycles at 5 ... 150 ... 5 Hz with load 0.8 In |
| Environmental Conditions: | 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 % |
| RoHS Status: | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
Technical UL/CSA
| Maximum Operating Voltage UL/CSA: | 480Y/277 V AC |
| Connecting Capacity UL/CSA: | Busbar 18-8 AWG Conductor 18-4 AWG |
| Tightening Torque UL/CSA: | 25 in·lb |
| Interrupting Rating acc. to UL1077: | (480 V AC) 10 kA (480Y / 277 V AC) 10 kA |
Certificates and Declarations (Document Number)
| Declaration of Conformity - CE: | 2CDK403003D0402 |
| Environmental Information: | 2CDK400030D0201 |
| Instructions and Manuals: | 2CSC400002D0208 |
| RoHS Information: | 2CDK400003K0201 |
Container Information
| Package Level 1 Units: | 1 piece |
| Package Level 1 Width: | 92 mm |
| Package Level 1 Depth / Length: | 58 mm |
| Package Level 1 Height: | 80 mm |
| Package Level 1 Gross Weight: | 0.435 kg |
| Package Level 1 EAN: | 4016779596886 |
Classifications
| Object Classification Code: | F |
| ETIM 4: | EC000042 - Miniature circuit breaker (MCB) |
| ETIM 5: | EC000042 - Miniature circuit breaker (MCB) |
| ETIM 6: | EC000042 - Miniature circuit breaker (MCB) |
| ETIM 7: | EC000042 - Miniature circuit breaker (MCB) |
| eClass: | 7.0 27141901 |
| UNSPSC: | 39121614 |