View larger
2CDS272061R0065
272061
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
The miniature circuit breaker S 200 M UC extends the established ABB System pro M compact® product range with an MCB for DC and AC applications. The S 200 M UC impresses with its performance range and the accordingly large amount of approvals. Its high inbuilt short circuit breaking capacity across the entire model line, its flexible AC and DC application and its approval and compliance in accordance with all major international and local standards make it truly unique. All current System pro M compact® accessories can be combined easily with the new model line. Whether warehousing or project engineering, planning, installing or maintaining your equipment, the S 200 M UC is a simple and flexible solution.
| Identifier | Type | Description | Qty | Unit Of Measure |
|---|---|---|---|---|
| 2CCA880100R0001 | CMS-100PS | Sensor 18mm, 80A AC, DC, TRMS, mounting for pro M compact & SMISSLINE | 1 | piece |
| 2CCA880101R0001 | CMS-101PS | Sensor 18mm, 40A AC, DC, TRMS, mounting for pro M compact & SMISSLINE | 1 | piece |
| 2CCA880102R0001 | CMS-102PS | Sensor 18mm, 20A AC, DC, TRMS, mounting for pro M compact & SMISSLINE | 1 | piece |
| 2CDS200909R0001 | S2C-A1 | S2C-A1 - Shunt Trip | 1 | piece |
| 2CDS200909R0002 | S2C-A2 | S2C-A2 - Shunt Trip | 1 | piece |
| 2CDS200912R0001 | S2C-H6R | S2C-H6R - Auxiliary Contact | 1 | piece |
| 2CDS200918R0001 | S2C-NT | S2C-NT - Hand Operated Neutral | 1 | piece |
| 2CDS200922R0001 | S2C-S/H6R | S2C-S/H6R - Signal / Auxiliary Contact | 1 | piece |
| 2CDS200936R0001 | S2C-H11L | S2C-H11L - Auxiliary Contact | 1 | piece |
| 2CDS200936R0002 | S2C-H20L | S2C-H20L - Auxiliary Contact | 1 | piece |
| 2CDS200936R0003 | S2C-H02L | S2C-H02L - Auxiliary Contact | 1 | piece |
| 2CDS200946R0001 | S2C-H6-11R | S2C-H6-11R - Auxiliary Contact | 1 | piece |
| 2CDS200946R0002 | S2C-H6-20R | S2C-H6-20R - Auxiliary Contact | 1 | piece |
| 2CDS200946R0003 | S2C-H6-02R | S2C-H6-02R - Auxiliary Contact | 1 | piece |
| 2CDS200970R0001 | S2C-H01 | S2C-H01 - Auxiliary Contact | 1 | piece |
| 2CDS200970R0002 | S2C-H10 | S2C-H10 - Auxiliary Contact | 1 | piece |
| 2CSS200911R0001 | S2C-UA 12 DC | S2C-UA 12 DC - Undervoltage release | 1 | piece |
| 2CSS200911R0002 | S2C-UA 24 AC | S2C-UA 24 AC - Undervoltage release | 1 | piece |
| 2CSS200911R0003 | S2C-UA 48 AC | S2C-UA 48 AC - Undervoltage release | 1 | piece |
| 2CSS200911R0004 | S2C-UA 110 AC | S2C-UA 110 AC - Undervoltage release | 1 | piece |
| 2CSS200911R0005 | S2C-UA 230 AC | S2C-UA 230 AC - Undervoltage release | 1 | piece |
| 2CSS200911R0006 | S2C-UA 400 AC | S2C-UA 400 AC - Undervoltage release | 1 | piece |
| 2CSS200911R0007 | S2C-UA 24 DC | S2C-UA 24 DC - Undervoltage release | 1 | piece |
| 2CSS200911R0008 | S2C-UA 48 DC | S2C-UA 48 DC - Undervoltage release | 1 | piece |
| 2CSS200911R0009 | S2C-UA 110 DC | S2C-UA 110 DC - Undervoltage release | 1 | piece |
| 2CSS200911R0010 | S2C-UA 230 DC - Undervoltage release | S2C-UA 230 DC | 1 | piece |
| 2CSS200998R0001 | S2C-BP - Mechanical tripping device | S2C-BP | 1 | piece |
| 2CSS200999R0001 | S2C-EST - Plug-in base | S2C-EST | 1 | piece |
| 2CSS201997R0013 | S2C-CM1 - Motor operating device | S2C-CM1 | 1 | piece |
| 2CSS203997R0013 | S2C-CM2/3 | S2C-CM2/3 - Motor operating device | 1 | piece |
| 2CSS204997R0013 | S2C-CM4 - Motor operating device | S2C-CM4 | 1 | piece |
| GHS2001901R0003 | S2C-DH | S2C-DH - Mechanical Accessories | 1 | piece |
| Feature Name | Feature Value |
|---|---|
| Built-in depth (EF000218) | 69 mm |
| Release characteristic (EF000889) | B |
| Number of poles (total) (EF008618) | 2 |
| Number of protected poles (EF005548) | 2 |
| Rated current (EF000227) | 6 A |
| Rated voltage (EF000228) | 400 V |
| Rated insulation voltage Ui (EF001366) | 440 V |
| Rated impulse withstand voltage Uimp (EF011980) | 4 kV |
| Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V (EF009556) | 10 kA |
| Voltage type (EF000187) | AC/DC |
| Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V (EF009555) | 10 kA |
| Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V (EF009557) | 15 kA |
| Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V (EF009558) | 15 kA |
| Frequency (EF000416) | 50 Hz |
| Current limiting class (EF002568) | 3 |
| Flush-mounted installation (EF007517) | No |
| Concurrently switching neutral conductor (EF005997) | No |
| Over voltage category (EF002569) | 3 |
| Pollution degree (EF002570) | 3 |
| Additional equipment possible (EF008148) | Yes |
| Width in number of modular spacings (EF002950) | 2.0 |
| Degree of protection (IP) (EF005474) | IP20 |
| Ambient temperature during operating (EF007515) | -25 °C |
| Connectable conductor cross section multi-wired (EF007343) | 0.75 mm² |
| Connectable conductor cross section solid-core (EF007337) | 0.75 mm² |
| Explosion-proof (EF004663) | No |