ABB 2CDS252001R0804 2CDS252001R0804 ABB Miniature Circuit Breaker S200 80-100A 2P C 80 A View larger
Images are for illustrative purposes only. Please refer to data sheet for details

2CDS252001R0804 ABB Miniature Circuit Breaker S200 80-100A 2P C 80 A

2CDS252001R0804

252001

ABB

1 Pcs.

Miniature Circuit Breaker - S200 80-100A - 2P - C - 80 A Int.aut. S202-C80 2p 80A C 6kA Miniature Circuit Breaker - S200 80-100A - 2P - 80 A - C - (AC) 6 kA

Automation > Miniature circuit breaker (MCB)
S200 80 y 100A

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

ABB EcoSolutions
EcoSolutions Profile9AKK108471A1000
Technical
Dielectric Test Voltage50 / 60 Hz - 1 min 2 kV
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 10 kA
(400 V AC) 6 kA
(400 V) 6 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(400 V AC) 6 kA
Power Supply ConnectionArbitrary
Contact Position IndicationRed ON / Green OFF
Energy Limiting Class3
Electrical Endurance10000 AC cycle
Mechanical Endurance20000 cycle
Number of Protected Poles2
Number of Poles2P
Tightening Torque3 N·m
Actuator TypeToggle
Screw Terminal TypeFailsafe Bi-directional Cylinder-lift Terminal
Actuator MarkingI / O
Actuator MaterialInsulation Group II, Black, Sealable
Recommended Screw DriverPozidriv 2
Accessories AvailableYes
Connecting CapacityBusbar 16/16 mm²
Conductor 2.5 ... 50 mm²
Flexible 4 ... 35 mm²
Rigid 2.5 ... 50 mm²
Stranded 2.5 ... 50 mm²
Installation Sizeacc. to DIN 43880 1
Terminal TypeScrew Terminals
Electrical
Tripping CharacteristicC
Rated Operational Voltageacc. to IEC 60898-1 400 V AC
acc. to IEC 60947-2 400 V AC
Operational VoltageMaximum (Incl. Tolerance) 440 V AC
Maximum (Incl. Tolerance) 110 V DC
Minimum 12 V AC
Minimum 12 V DC
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 440 V
Rated Impulse Withstand Voltage (Uimp)4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
Input Voltage TypeAC
Rated Current (In)80 A
Rated Short-Circuit Capacity(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(400 V AC) 6 kA
(400 V) 6 kA
Rated Conditional Short-Circuit Current (Inc)(230 V) 10 kA
(400 V) 20 kA
Rated Frequency (f)50 / 60 Hz
Power Loss29.4 W
at Rated Operating Conditions per Pole 9.8 W
Overvoltage CategoryIII
Design
Housing MaterialInsulation Group I, RAL 7035
Material Compliance
RoHS Declaration2CDK400601D2703
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date20200320
REACH Declaration9AKK107492A1906
REACH InformationFalse - does not contain substances > 0.1 mass percentage
REACH Date20240821
Conflict Minerals Reporting Template (CMRT)9AKK108468A3363
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2BBusiness To Business
Environmental
Ambient Air TemperatureOperation -25 ... +55 °C
Storage -40 ... +70 °C
Reference Ambient Air Temperature30 °C
Degree of ProtectionIP20
IP40
Enclosure with Cover IP40
Pollution Degree3
Environmental Conditions28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
Resistance to Vibrations20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
Resistance to Shock acc. to IEC 60068-2-2725g 2 shocks 13 ms
Dimensions
Width in Number of Modular Spacings2.0
Product Net Width35 mm
Product Net Height88 mm
Product Net Depth / Length69 mm
Product Net Weight0.24 kg
Built-In Depth (t2)69 mm
Engineering
EPLAN Data9AAC185394_EPLAN
Ordering
Package Level 1 Unitscarton 5 piece
Package Level 1 Gross Weight1.24 kg
E-Number (Finland)3210634
E-Number (Norway)1682947
Certificates and Declarations
Declaration of Conformity - CE2CDK400601D2703
Declaration of Conformity - UKCA9AKK108467A5198
Installation
Instructions and Manuals2CDS207104P0002
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting Positionany
Popular Downloads
Data Sheet, Technical Information9AKK107680A3031
External Classifications and Standards
ETIM 9EC000042 - Miniature circuit breaker (MCB)
ETIM 10EC000042 - Miniature circuit breaker (MCB)
UNSPSC39121603
eClassV11.0 : 27141901
IDEA Granular Category Code (IGCC)4897 >> Miniature circuit breakers
Object Classification CodeF
StandardsIEC/EN 60898-1
IEC/EN 60947-2
Certification AgencyEN
IEC
Standardization BodyEN
IEC

ETIM for 2CDS252001R0804 Circuit breakers and fuses (EC000042)
Feature Name Feature Value
Built-in depth (EF000218) 69 mm
Release characteristic (EF000889) C
Number of poles (total) (EF008618) 2
Number of protected poles (EF005548) 2
Rated current (EF000227) 80 A
Rated voltage (EF000228) 400 V
Rated insulation voltage Ui (EF001366) 440 V
Rated impulse withstand voltage Uimp (EF011980) 4 kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V (EF009556) 6 kA
Voltage type (EF000187) AC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V (EF009555) 6 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V (EF009557) 10 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V (EF009558) 6 kA
Frequency (EF000416) 50 Hz
Current limiting class (EF002568) 3
Flush-mounted installation (EF007517) No
Concurrently switching neutral conductor (EF005997) No
Over voltage category (EF002569) 3
Pollution degree (EF002570) 3
Additional equipment possible (EF008148) Yes
Width in number of modular spacings (EF002950) 2.0
Degree of protection (IP) (EF005474) IP20
Ambient temperature during operating (EF007515) -25 °C
Connectable conductor cross section multi-wired (EF007343) 35 mm²
Connectable conductor cross section solid-core (EF007337) 2.5 mm²
Explosion-proof (EF004663) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.