Miniature Circuit Breaker - S200 80-100A - 2P - B - 80 A Int.aut. S202-B80 2p 80A B 6kA Miniature Circuit Breaker - S200 80-100A - 2P - 80 A - B - (AC) 6 kA

Automation > Miniature circuit breaker (MCB)
S200 80 y 100A

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Designed for high-current sub-distribution, this ABB Miniature Circuit Breaker S200 protects heavy electrical loads from damaging overcurrent and short-circuit events. Industrial enclosures and commercial switchboards rely on these thermal-magnetic breakers to maintain circuit integrity and protect valuable equipment.

Final pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • ABB EcoSolutions: Yes
  • EcoSolutions Profile: 9AKK108471A1000
  • Dielectric Test Voltage: 50 / 60 Hz - 1 min 2 kV
  • Rated Ultimate Short-Circuit Breaking Capacity (I cu ): (230 V AC) 10 kA
  • Rated Service Short-Circuit Breaking Capacity (I cs ): (400 V AC) 6 kA
  • Power Supply Connection: Arbitrary
  • Contact Position Indication: Red ON / Green OFF
  • Energy Limiting Class: 3
  • Electrical Endurance: 10000 AC cycle
  • Mechanical Endurance: 20000 cycle
  • Number of Protected Poles: 2
  • Number of Poles: 2P
  • Tightening Torque: 3 N·m
  • Actuator Type: Toggle
  • Screw Terminal Type: Failsafe Bi-directional Cylinder-lift Terminal
  • Actuator Marking: I / O

More info

▲
ABB EcoSolutions
ABB EcoSolutionsYes
EcoSolutions Profile9AKK108471A1000
Technical
Dielectric Test Voltage50 / 60 Hz - 1 min 2 kV
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 10 kA
(400 V AC) 6 kA
(400 V) 6 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(400 V AC) 6 kA
Power Supply ConnectionArbitrary
Contact Position IndicationRed ON / Green OFF
Energy Limiting Class3
Electrical Endurance10000 AC cycle
Mechanical Endurance20000 cycle
Number of Protected Poles2
Number of Poles2P
Tightening Torque3 N·m
Actuator TypeToggle
Screw Terminal TypeFailsafe Bi-directional Cylinder-lift Terminal
Actuator MarkingI / O
Actuator MaterialInsulation Group II, Black, Sealable
Recommended Screw DriverPozidriv 2
Accessories AvailableYes
Connecting CapacityBusbar 16/16 mm²
Conductor 2.5 ... 50 mm²
Flexible 4 ... 35 mm²
Rigid 2.5 ... 50 mm²
Stranded 2.5 ... 50 mm²
Installation Sizeacc. to DIN 43880 1
Terminal TypeScrew Terminals
Electrical
Tripping CharacteristicB
Rated Operational Voltageacc. to IEC 60898-1 400 V AC
acc. to IEC 60947-2 400 V AC
Operational VoltageMaximum (Incl. Tolerance) 440 V AC
Maximum (Incl. Tolerance) 110 V DC
Minimum 12 V AC
Minimum 12 V DC
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 440 V
Rated Impulse Withstand Voltage (Uimp)4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
Input Voltage TypeAC
Rated Current (In)80 A
Rated Short-Circuit Capacity(AC) 6 kA
(DC) 6 kA
(230 V AC) 6 kA
(400 V AC) 6 kA
(400 V) 6 kA
Rated Conditional Short-Circuit Current (Inc)(230 V) 10 kA
(400 V) 20 kA
Rated Frequency (f)50 / 60 Hz
Power Loss16.2 W
at Rated Operating Conditions per Pole 8.1 W
Overvoltage CategoryIII
Design
Housing MaterialInsulation Group I, RAL 7035
Material Compliance
RoHS Declaration2CDK400601D2703
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date20200320
REACH Declaration9AKK107492A1906
REACH InformationFalse - does not contain substances > 0.1 mass percentage
REACH Date20251028
Conflict Minerals Reporting Template (CMRT)9AKK108468A3363
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2BBusiness To Business
Environmental
Ambient Air TemperatureOperation -25 ... +55 °C
Storage -40 ... +70 °C
Reference Ambient Air Temperature30 °C
Degree of ProtectionIP20
IP40
Enclosure with Cover IP40
Pollution Degree3
Environmental Conditions28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
Resistance to Vibrations20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
Resistance to Shock acc. to IEC 60068-2-2725g 2 shocks 13 ms
Dimensions
Width in Number of Modular Spacings2.0
Product Net Width35 mm
Product Net Height88 mm
Product Net Depth / Length69 mm
Product Net Weight0.24 kg
Built-In Depth (t2)69 mm
Engineering
EPLAN Data9AAC185394_EPLAN
Ordering
Package Level 1 Unitscarton 5 piece
Package Level 1 Gross Weight1.46 kg
E-Number (Finland)3210614
E-Number (Norway)1682950
Certificates and Declarations
Declaration of Conformity - CE2CDK400601D2703
Declaration of Conformity - UKCA9AKK108467A5198
Installation
Instructions and Manuals2CDS207104P0002
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting Positionany
Popular Downloads
Data Sheet, Technical Information9AKK107680A3031
External Classifications and Standards
ETIM 9EC000042 - Miniature circuit breaker (MCB)
ETIM 10EC000042 - Miniature circuit breaker (MCB)
UNSPSC39121603
eClassV11.0 : 27141901
IDEA Granular Category Code (IGCC)4897 >> Miniature circuit breakers
Object Classification CodeF
StandardsIEC/EN 60898-1
IEC/EN 60947-2
Certification AgencyEN
IEC
Standardization BodyEN
IEC

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.