ABB 2CDS252001R0825 2CDS252001R0825 ABB Miniature Circuit Breaker S200 80-100A 2P B 100 A View larger
Images are for illustrative purposes only. Please refer to data sheet for details

2CDS252001R0825 ABB Miniature Circuit Breaker S200 80-100A 2P B 100 A

2CDS252001R0825

252001

ABB

1 Pcs.

Miniature Circuit Breaker - S200 80-100A - 2P - B - 100 A Int.aut. S202-B100 2p 100A B 6kA Automatic switch - S200 80-100A - 2P - 100 A - B - (AC) 6 kA

Automation > Miniature circuit breaker (MCB)
S200 80 y 100A

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

S202-B100 MCB B-Char., 6kA, 100A, 2P

Ordering

  • EAN:
    4016779916691
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85362090

Dimensions

  • Product Net Width:
    35mm
  • Product Net Depth:
    69mm
  • Product Net Height:
    88.8mm
  • Product Net Weight:
    0.28kg

Container Information

  • Package Level 1 Units:
    5 piece
  • Package Level 1 Width:
    92 mm
  • Package Level 1 Length:
    183 mm
  • Package Level 1 Height:
    80 mm
  • Package Level 1 Gross Weight:
    16 kg
  • Package Level 1 EAN:
    4016779918138
  • Package Level 2 Units:
    60 piece
  • Package Level 2 Width:
    275 mm
  • Package Level 2 Length:
    395 mm
  • Package Level 2 Height:
    210 mm
  • Package Level 2 Gross Weight:
    14.8 kg
  • Package Level 2 EAN:
    4016779919579

Environmental

  • Ambient Air Temperature:
    Operation -25 ... +55 °C
    Storage -40 ... +70 °C
  • Resistance to Shock acc. to IEC 60068-2-27:
    25g / 2 shocks / 13 ms
  • Resistance to Vibrations acc. to IEC 60068-2-6:
    5g, 20 cycles at 5 ... 150 ... 5 Hz with load 0.8 In
  • Environmental Conditions:
    28 cycles
    with 55 °C / 90-96 %
    and 25 °C / 95-100 %

Technical

  • Standards:
    IEC/EN 60898-1
    IEC/EN 60947-2
  • Number of Poles:
    2
  • Tripping Characteristic:
    B
  • Rated Current (In):
    100 A
  • Rated Operational Voltage:
    acc. to IEC 60898-1 110 V DC
    acc. to IEC 60898-1 400 V AC
  • Rated Insulation Voltage (Ui):
    acc. toIEC/EN 60664-1 500 V
  • Operational Voltage:
    Maximum (Incl. Tolerance) 440 V AC
    Minimum 12 V AC / 12 V DC
  • Rated Frequency (f):
    50 Hz
    60 Hz
  • Rated Short-Circuit Capacity (Icn):
    6 kA
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu):
    6 kA
  • Rated Service Short-Circuit Breaking Capacity (Ics):
    6 kA
  • Overvoltage Category:
    III
  • Pollution Degree:
    3
  • Rated Impulse Withstand Voltage (Uimp):
    4 kV
    (6.2 kV @ sea level)
    (5.0 kV @ 2000 m)
  • Dielectric Test Voltage:
    50 / 60 Hz, 1 min: 2 kV
  • Housing Material:
    Insulation Group I, RAL 7035
  • Actuator Type:
    Toggle
  • Contact Position Indication:
    ON / OFF
  • Degree of Protection:
    IP20
  • Remarks:
    IP40 in enclosure with cover
  • Electrical Endurance:
    10000 AC cycle
  • Mechanical Endurance:
    20000 cycle
  • Terminal Type:
    Screw Terminals
  • Screw Terminal Type:
    Failsafe Bi-directional Cylinder-lift Terminal
  • Connecting Capacity:
    Busbar 16 / 16 mm²
  • Tightening Torque:
    3 N·m
  • Recommended Screw Driver:
    Pozidriv 2
  • Mounting on DIN Rail:
    TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
    TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • Mounting Position:
    Any

Certificates and Declarations (Document Number)

Classifications

  • eClass:
    7.0 27141901
  • ETIM 5:
    EC000042 - Miniature circuit breaker (MCB)
  • UNSPSC:
    39121614

ETIM for 2CDS252001R0825 Circuit breakers and fuses (EC000042)
Feature Name Feature Value
Built-in depth (EF000218) 69 mm
Release characteristic (EF000889) B
Number of poles (total) (EF008618) 2
Number of protected poles (EF005548) 2
Rated current (EF000227) 100 A
Rated voltage (EF000228) 400 V
Rated insulation voltage Ui (EF001366) 440 V
Rated impulse withstand voltage Uimp (EF011980) 4 kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V (EF009556) 6 kA
Voltage type (EF000187) AC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V (EF009555) 6 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V (EF009557) 10 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V (EF009558) 6 kA
Frequency (EF000416) 50 Hz
Current limiting class (EF002568) 3
Flush-mounted installation (EF007517) No
Concurrently switching neutral conductor (EF005997) No
Over voltage category (EF002569) 3
Pollution degree (EF002570) 3
Additional equipment possible (EF008148) Yes
Width in number of modular spacings (EF002950) 2.0
Degree of protection (IP) (EF005474) IP20
Ambient temperature during operating (EF007515) -25 °C
Connectable conductor cross section multi-wired (EF007343) 35 mm²
Connectable conductor cross section solid-core (EF007337) 2.5 mm²
Explosion-proof (EF004663) No