View larger
2CDS252001R0164
252001
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 and CSA 22.2 No. 235, allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200 to save 50% space.
| Identifier | Type | Description | Qty | Unit Of Measure |
|---|---|---|---|---|
| 2CCA880100R0001 | CMS-100PS | Sensor 18mm, 80A AC, DC, TRMS, mounting for pro M compact & SMISSLINE | 1 | piece |
| 2CCA880101R0001 | CMS-101PS | Sensor 18mm, 40A AC, DC, TRMS, mounting for pro M compact & SMISSLINE | 1 | piece |
| 2CCA880102R0001 | CMS-102PS | Sensor 18mm, 20A AC, DC, TRMS, mounting for pro M compact & SMISSLINE | 1 | piece |
| 2CDS200909R0001 | S2C-A1 | S2C-A1 - Shunt Trip | 1 | piece |
| 2CDS200909R0002 | S2C-A2 | S2C-A2 - Shunt Trip | 1 | piece |
| 2CDS200912R0001 | S2C-H6R | S2C-H6R - Auxiliary Contact | 1 | piece |
| 2CDS200918R0001 | S2C-NT | S2C-NT - Hand Operated Neutral | 1 | piece |
| 2CDS200922R0001 | S2C-S/H6R | S2C-S/H6R - Signal / Auxiliary Contact | 1 | piece |
| 2CDS200936R0001 | S2C-H11L | S2C-H11L - Auxiliary Contact | 1 | piece |
| 2CDS200936R0002 | S2C-H20L | S2C-H20L - Auxiliary Contact | 1 | piece |
| 2CDS200936R0003 | S2C-H02L | S2C-H02L - Auxiliary Contact | 1 | piece |
| 2CDS200946R0001 | S2C-H6-11R | S2C-H6-11R - Auxiliary Contact | 1 | piece |
| 2CDS200946R0002 | S2C-H6-20R | S2C-H6-20R - Auxiliary Contact | 1 | piece |
| 2CDS200946R0003 | S2C-H6-02R | S2C-H6-02R - Auxiliary Contact | 1 | piece |
| 2CDS200970R0001 | S2C-H01 | S2C-H01 - Auxiliary Contact | 1 | piece |
| 2CDS200970R0002 | S2C-H10 | S2C-H10 - Auxiliary Contact | 1 | piece |
| 2CSS200911R0001 | S2C-UA 12 DC | S2C-UA 12 DC - Undervoltage release | 1 | piece |
| 2CSS200911R0002 | S2C-UA 24 AC | S2C-UA 24 AC - Undervoltage release | 1 | piece |
| 2CSS200911R0003 | S2C-UA 48 AC | S2C-UA 48 AC - Undervoltage release | 1 | piece |
| 2CSS200911R0004 | S2C-UA 110 AC | S2C-UA 110 AC - Undervoltage release | 1 | piece |
| 2CSS200911R0005 | S2C-UA 230 AC | S2C-UA 230 AC - Undervoltage release | 1 | piece |
| 2CSS200911R0006 | S2C-UA 400 AC | S2C-UA 400 AC - Undervoltage release | 1 | piece |
| 2CSS200911R0007 | S2C-UA 24 DC | S2C-UA 24 DC - Undervoltage release | 1 | piece |
| 2CSS200911R0008 | S2C-UA 48 DC | S2C-UA 48 DC - Undervoltage release | 1 | piece |
| 2CSS200911R0009 | S2C-UA 110 DC | S2C-UA 110 DC - Undervoltage release | 1 | piece |
| 2CSS200911R0010 | S2C-UA 230 DC - Undervoltage release | S2C-UA 230 DC | 1 | piece |
| 2CSS200998R0001 | S2C-BP - Mechanical tripping device | S2C-BP | 1 | piece |
| 2CSS200999R0001 | S2C-EST - Plug-in base | S2C-EST | 1 | piece |
| 2CSS201997R0013 | S2C-CM1 - Motor operating device | S2C-CM1 | 1 | piece |
| 2CSS203997R0013 | S2C-CM2/3 | S2C-CM2/3 - Motor operating device | 1 | piece |
| 2CSS204997R0013 | S2C-CM4 - Motor operating device | S2C-CM4 | 1 | piece |
| GHS2001901R0003 | S2C-DH | S2C-DH - Mechanical Accessories | 1 | piece |
| Feature Name | Feature Value |
|---|---|
| Built-in depth (EF000218) | 69 mm |
| Release characteristic (EF000889) | C |
| Number of poles (total) (EF008618) | 2 |
| Number of protected poles (EF005548) | 2 |
| Rated current (EF000227) | 16 A |
| Rated voltage (EF000228) | 400 V |
| Rated insulation voltage Ui (EF001366) | 440 V |
| Rated impulse withstand voltage Uimp (EF011980) | 4 kV |
| Voltage type (EF000187) | AC/DC |
| Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V (EF009555) | 6 kA |
| Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V (EF009557) | 20 kA |
| Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V (EF009558) | 10 kA |
| Frequency (EF000416) | 50 Hz |
| Current limiting class (EF002568) | 3 |
| Flush-mounted installation (EF007517) | No |
| Concurrently switching neutral conductor (EF005997) | No |
| Over voltage category (EF002569) | 3 |
| Pollution degree (EF002570) | 3 |
| Additional equipment possible (EF008148) | Yes |
| Width in number of modular spacings (EF002950) | 2.0 |
| Degree of protection (IP) (EF005474) | IP20 |
| Ambient temperature during operating (EF007515) | -25 °C |
| Connectable conductor cross section multi-wired (EF007343) | 0.75 mm² |
| Connectable conductor cross section solid-core (EF007337) | 0.75 mm² |
| Explosion-proof (EF004663) | No |