View larger
Images are for illustrative purposes only. Please refer to data sheet for details
2CCS863001R1557 ABB High Performance Circuit Breaker S800S Tripping characteristic K Number of poles 3 Rated..
2CCS863001R1557
863001
ABB
1 Pcs.
High Performance Circuit Breaker - S800S - Tripping characteristic K - Number of poles 3 - Rated operational current 40A - Rated operational voltage 750V DC
Int.aut. S803S-UCK40 3p 40A UCK 50kA
S803S-UCK40 High Performance MCB
Automation > Miniature circuit breaker (MCB)
S800S-UC
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb 2CCS863001R1557 S800S high performance circuit breaker provides robust protection for heavy-duty electrical installations subjected to high prospective fault currents.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- EcoSolutions Profile: 9AKK108471A1082
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 86.29 %
- ABB Site Meeting Group Waste To Landfill Target: No non-hazardous waste is sent to a landfill
- End Of Life Disassembling Instructions: 9AKK108470A2575
- Environmental Product Declaration - EPD: 9AKK108470A1695
- Type of Residual Current: Standard Version
- Rated Ultimate Short-Circuit Breaking Capacity (I cu ): (750 V DC) 50 kA
- Rated Service Short-Circuit Breaking Capacity (I cs ): (750 V DC) 50 kA
- Contact Position Indication: ON / OFF / TRIP
- Energy Limiting Class: 3
- Number of Protected Poles: 3
- Number of Poles: 3P
- Release Type: K
- Actuator Marking: I / O
- Accessories Available: Yes
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| EcoSolutions Profile | 9AKK108471A1082 |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 86.29 % |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| End Of Life Disassembling Instructions | 9AKK108470A2575 |
| Environmental Product Declaration - EPD | 9AKK108470A1695 |
| 9AKK108470A1696 | |
| Technical | |
| Type of Residual Current | Standard Version |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (750 V DC) 50 kA |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (750 V DC) 50 kA |
| Contact Position Indication | ON / OFF / TRIP |
| Energy Limiting Class | 3 |
| Number of Protected Poles | 3 |
| Number of Poles | 3P |
| Release Type | K |
| Actuator Marking | I / O |
| Accessories Available | Yes |
| Connecting Capacity | Flexible 0 … 50 mm² |
| Rigid 0 … 70 mm² | |
| Terminal Type | Screw Terminals |
| Electrical | |
| Tripping Characteristic | UC-K |
| Rated Operational Voltage | acc. to IEC 60947-2 750 V DC |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 1500 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Input Voltage Type | DC |
| Rated Current (In) | 40 A |
| Frequency (f) | 0...0 Hz |
| Rated Frequency (f) | 0 Hz |
| Power Loss | Total 11.1 W |
| at Rated Operating Conditions per Pole 3.7 W | |
| Overvoltage Category | III |
| Material Compliance | |
| RoHS Declaration | 2CCC005084D0202 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20211214 |
| REACH Declaration | 9AKK108470A9089 |
| REACH Information | False - does not contain substances > 0.1 mass percentage |
| REACH Date | 20250313 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Business |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 70 °C |
| Storage -40 ... 70 °C | |
| Degree of Protection | IP20 |
| Pollution Degree | 2 |
| Environmental Information | 2CCY413207D0203 |
| Dimensions | |
| Width in Number of Modular Spacings | 4.5 |
| Product Net Width | 81 mm |
| Product Net Height | 95 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 735 g |
| Built-In Depth (t2) | 82.5 mm |
| Dimension Diagram | 2CCC413003C0201 |
| Engineering | |
| EPLAN Data | 9AAC172534_EPLAN |
| Ordering | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 770 g |
| Certificates and Declarations | |
| CB Certificate | 2CCC413025D0202 |
| CCC Certificate | CQC2007010307251328 |
| Declaration of Conformity - CE | 2CCC005084D0202 |
| ESTI Certificate | S800 GOST |
| VDE Certificate | 2CCC413040D0601 |
| Installation | |
| Instructions and Manuals | 2CCC413016M0008 |
| Popular Downloads | |
| Data Sheet, Technical Information | 9AKK108468A9560 |
| 9AKK108468A9561 | |
| 9AKK108468A9562 | |
| External Classifications and Standards | |
| ETIM 9 | EC000042 - Miniature circuit breaker (MCB) |
| ETIM 10 | EC000042 - Miniature circuit breaker (MCB) |
| UNSPSC | 39121603 |
| eClass | V11.0 : 27141901 |
| Object Classification Code | F |
| Standards | IEC/EN 60947-2 |