View larger
1SFL637025R6811
637025
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| EPLAN Data | 9AAC171153_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Data Sheet, Technical Information (Part 2) | 1SAC200017M0002 |
| Instructions and Manuals | 1SFC101045M9701 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Depth / Length | 242 mm |
| Product Net Height | 283 mm |
| Product Net Weight | 14 kg |
| Dimension Diagram | 53540919-60 |
| Technical | |
| Number of Main Contacts NO | 1 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 1P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A |
| Rated Operational Current DC-1 (Ie) | (1000 V) 3 Poles in Series, 40 °C 1050 A |
| (1000 V) 3 Poles in Series, 55 °C 875 A | |
| (1000 V) 3 Poles in Series, 70 °C 720 A | |
| (220 V) 3 Poles in Series, 40 °C 1050 A | |
| (220 V) 3 Poles in Series, 55 °C 875 A | |
| (220 V) 3 Poles in Series, 70 °C 720 A | |
| (400 V) 3 Poles in Series, 40 °C 1050 A | |
| (400 V) 3 Poles in Series, 55 °C 875 A | |
| (400 V) 3 Poles in Series, 70 °C 720 A | |
| (600 V) 3 Poles in Series, 40 °C 1050 A | |
| (600 V) 3 Poles in Series, 55 °C 875 A | |
| (600 V) 3 Poles in Series, 70 °C 720 A | |
| Rated Insulation Voltage (Ui) | acc. to UL/CSA 1000 V |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Mechanical Durability | 3 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | DC Operation 24 ... 60 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | |
| Holding at Max. Rated Control Circuit Voltage DC 5.5 V·A | |
| Holding at Max. Rated Control Circuit Voltage DC 4.5 W | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 850 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 850 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage DC 950 V·A | |
| Power Loss | at Rated Operating Conditions per Pole 50 W |
| Connecting Capacity Main Circuit | Bar 52 mm² |
| Bar 50 mm² | |
| Rigid Al-Cable 300 mm² | |
| Rigid Al-Cable 3x185 mm² | |
| Rigid Cu-Cable 300 mm² | |
| Rigid Cu-Cable 3x185 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1x 0.75 ... 2.5 mm² |
| Flexible with Ferrule 2x 0.75 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
| Flexible 2x0.75 ... 2.5 mm² | |
| Solid 2 x 1 ... 4 mm² | |
| Stranded 2 x 1 .... 4 mm² | |
| Connecting Capacity | Bar 52 mm² |
| Rigid Al-Cable 3x185 mm² | |
| Rigid Cu-Cable 3x185 mm² | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 | |
| Connecting Terminals (delivered in open position) Main Poles | M 3.5 (+,-) pozidriv 2 screw with cable clamp |
| Recommended Screw Driver | Main Circuit M12 |
| Control Circuit Pozidriv 2 | |
| Control Circuit M3.5 | |
| Tightening Torque | Cable Lug 45 N·m |
| Main Circuit 45 N·m | |
| Terminal Type | Main Circuit: Bars |
| Suitable for Product Class | Block ContactorsBlock Contactors |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
| General Use Rating UL/CSA | (1000 V DC) 900 A |
| (440 V DC) 900 A | |
| (600 V DC) 900 A | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | |
| Close to Contactor for Storage -40 ... 70 °C | |
| Operation -40 ... 70 °C | |
| Storage -40 ... +70 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Shock Direction: A 5 g |
| Shock Direction: B1 5 g | |
| Shock Direction: B2 5 g | |
| Shock Direction: C1 5 g | |
| Shock Direction: C2 5 g | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| CB Certificate | SEMKO_SE-70018 |
| CQC Certificate | CQC2013010304595900 |
| Declaration of Conformity - CCC | 2020980304001858 |
| Declaration of Conformity - CE | 2CMT003517 |
| Declaration of Conformity - UKCA | 2CMT2020-006118 |
| EAC Certificate | 9AKK107046A8618 |
| UL Certificate | 20130524-E73397 |
| UL Listing Card | UL_E73397 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 280 mm |
| Package Level 1 Depth / Length | 375 mm |
| Package Level 1 Height | 310 mm |
| Package Level 1 Gross Weight | 15 kg |
| Package Level 1 EAN | 7320500400838 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC002552 - Power contactor, DC switching |
| ETIM 8 | EC002552 - Power contactor, DC switching |
| ETIM 9 | EC002552 - Power contactor, DC switching |
| eClass | V11.0 : 27371018 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4763 >> Power contactor, DC switching |
| Feature Name | Feature Value |
|---|---|
| Rated control supply voltage DC (EF003980) | 24 V |
| Voltage type for actuating (EF008242) | DC |
| Modular version (EF001126) | No |
| Number of auxiliary contacts as normally open contact (EF001376) | 1 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 1 |
| Type of electrical connection of main circuit (EF006819) | Connection rail |
| Number of normally closed contacts as main contact (EF001375) | 0 |
| Number of normally open contacts as main contact (EF001374) | 1 |