View larger
1SFL597025R7011 ABB GAF460-10-11 100-250V 50/60Hz / 100-250V DC Contactor
1SFL597025R7011
597025
ABB
1 Pcs.
Automation > Power contactor, DC switching
"A" SECRLP
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB Contactor (part number 1SFL597025R7011) functions as a heavy-duty electromechanical switch utilized in industrial automation to establish and interrupt high-power electrical circuits. Devices of this category are standard in motor control centers, large-scale power distribution, and automated manufacturing systems where dependable remote switching is vital.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- EPLAN Data: 9AAC171152_EPLAN
- Data Sheet, Technical Information: 1SBC100214C0202
- Data Sheet, Technical Information (Part 2): 1SAC200017M0002
- Instructions and Manuals: 1SFC101045M9701
- CAD Dimensional Drawing: 2CDC001079B0201
- Product Net Width: 186 mm
- Product Net Depth / Length: 216 mm
- Product Net Height: 278 mm
- Product Net Weight: 10.6 kg
- Dimension Diagram: 53540919-59
- Number of Main Contacts NO: 1
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 1
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| EPLAN Data | 9AAC171152_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Data Sheet, Technical Information (Part 2) | 1SAC200017M0002 |
| Instructions and Manuals | 1SFC101045M9701 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 186 mm |
| Product Net Depth / Length | 216 mm |
| Product Net Height | 278 mm |
| Product Net Weight | 10.6 kg |
| Dimension Diagram | 53540919-59 |
| Technical | |
| Number of Main Contacts NO | 1 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 1P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 700 A |
| Rated Operational Current DC-1 (Ie) | (1000 V) 3 Poles in Series, 40 °C 700 A |
| (1000 V) 3 Poles in Series, 55 °C 600 A | |
| (1000 V) 3 Poles in Series, 70 °C 480 A | |
| (220 V) 3 Poles in Series, 40 °C 700 A | |
| (220 V) 3 Poles in Series, 55 °C 600 A | |
| (220 V) 3 Poles in Series, 70 °C 480 A | |
| (400 V) 3 Poles in Series, 40 °C 700 A | |
| (400 V) 3 Poles in Series, 55 °C 600 A | |
| (400 V) 3 Poles in Series, 70 °C 480 A | |
| (600 V) 3 Poles in Series, 40 °C 700 A | |
| (600 V) 3 Poles in Series, 55 °C 600 A | |
| (600 V) 3 Poles in Series, 70 °C 480 A | |
| Short-Circuit Protective Devices | gG Type Fuses 800 A |
| Rated Insulation Voltage (Ui) | acc. to UL/CSA 1000 V |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Mechanical Durability | 3 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 100 ... 250 V |
| 60 Hz 100 ... 250 V | |
| DC Operation 100 ... 250 V | |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | |
| Holding at Max. Rated Control Circuit Voltage DC 7.5 V·A | |
| Holding at Max. Rated Control Circuit Voltage DC 4 W | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 890 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 890 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage DC 990 V·A | |
| Power Loss | at Rated Operating Conditions per Pole 42 W |
| Connecting Capacity Main Circuit | Bar 47 mm² |
| Rigid Al-Cable 2x240 mm² | |
| Rigid Cu-Cable 240 mm² | |
| Rigid Cu-Cable 2x240 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1x 0.75 ... 2.5 mm² |
| Flexible with Ferrule 2x 0.75 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
| Flexible 2x0.75 ... 2.5 mm² | |
| Solid 2 x 1 ... 4 mm² | |
| Stranded 1 x 1 .... 4 mm² | |
| Stranded 2 x 1 .... 4 mm² | |
| Connecting Capacity | Bar 47 mm² |
| Rigid Al-Cable 2x240 mm² | |
| Rigid Cu-Cable 2x240 mm² | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 | |
| Connecting Terminals (delivered in open position) Main Poles | M 3.5 (+,-) pozidriv 2 screw with cable clamp |
| Recommended Screw Driver | Main Circuit M10 |
| Control Circuit Pozidriv 2 | |
| Control Circuit M3.5 | |
| Tightening Torque | Cable Lug 35 N·m |
| Main Circuit 35 N·m | |
| Terminal Type | Main Circuit: Bars |
| Suitable for Product Class | Block ContactorsBlock Contactors |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Horsepower Rating NEMA | (200 V AC) Three Phase 150 Hp |
| (230 V AC) Three Phase 200 Hp | |
| (460 V AC) Three Phase 400 Hp | |
| Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
| General Use Rating UL/CSA | (1000 V DC) 650 A |
| (440 V DC) 650 A | |
| (600 V AC) 650 A | |
| (600 V DC) 650 A | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | |
| Close to Contactor for Storage -40 ... 70 °C | |
| Operation -40 ... 70 °C | |
| Storage -40 ... +70 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Shock Direction: A 5 g |
| Shock Direction: B1 5 g | |
| Shock Direction: B2 5 g | |
| Shock Direction: C1 5 g | |
| Shock Direction: C2 5 g | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| End Of Life Disassembling Instructions | 1SFC100112M0003 |
| Environmental Product Declaration - EPD | 1SFC100105D0201 |
| Certificates and Declarations | |
| CB Certificate | SEMKO_SE-66699 |
| CQC Certificate | CQC2012010304547008 |
| Declaration of Conformity - CCC | 2020980304001542 |
| Declaration of Conformity - CE | 2CMT003517 |
| Declaration of Conformity - UKCA | 2CMT2020-006118 |
| EAC Certificate | 9AKK107046A8618 |
| UL Certificate | 20130517-E73397 |
| UL Listing Card | UL_E73397 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 280 mm |
| Package Level 1 Depth / Length | 375 mm |
| Package Level 1 Height | 310 mm |
| Package Level 1 Gross Weight | 12 kg |
| Package Level 1 EAN | 7320500383971 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC002552 - Power contactor, DC switching |
| ETIM 8 | EC002552 - Power contactor, DC switching |
| ETIM 9 | EC002552 - Power contactor, DC switching |
| eClass | V11.0 : 27371018 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4763 >> Power contactor, DC switching |
| E-Number (Finland) | 3709745 |