View larger
1SBL419025R8811 ABB GAE75-10-11 220V DC Contactor
1SBL419025R8811
419025
ABB
1 Pcs.
Automation > Power contactor, DC switching
"A" FRCTLP
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The ABB GAE75-10-11 contactor is a specialized electromechanical switching device built to regulate direct current applications in industrial environments. System integrators deploy this unit within control panels to manage heavy DC power distribution and motor actuation reliably. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Data Sheet, Technical Information: 1SBC100122C0202_CH02
- Instructions and Manuals: FPTC407691P0003
- CAD Dimensional Drawing: 2CDC001079B0201
- Product Net Width: 94 mm
- Product Net Depth / Length: 108 mm
- Product Net Height: 132 mm
- Product Net Weight: 1.3 kg
- Number of Main Contacts NO: 1
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 1
- Rated Operational Voltage: Auxiliary Circuit 690 V
- Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (I th ): acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SBC100122C0202_CH02 |
| Instructions and Manuals | FPTC407691P0003 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 94 mm |
| Product Net Depth / Length | 108 mm |
| Product Net Height | 132 mm |
| Product Net Weight | 1.3 kg |
| Technical | |
| Number of Main Contacts NO | 1 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Main Circuit 1000 V DC | |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A |
| acc. to IEC 60947-5-1, Θ = 40 °C 16 A | |
| Rated Operational Current AC-15 (Ie) | (500 V) 2 A |
| (690 V) 2 A | |
| (24 / 127 V) 6 A | |
| (220 / 240 V) 4 A | |
| (380 / 400 V) 3 A | |
| Rated Operational Current DC-1 (Ie) | (1000 V) 1-Pole, 40 °C 35 A |
| (1000 V) 1-Pole, 55 °C 35 A | |
| (1000 V) 1 Pole, 70 °C 35 A | |
| (110 V) 1-Pole, 40 °C 120 A | |
| (110 V) 1-Pole, 55 °C 100 A | |
| (110 V) 1-Pole, 70 °C 85 A | |
| (220 V) 1-Pole, 40 °C 120 A | |
| (220 V) 1-Pole, 55 °C 100 A | |
| (220 V) 1-Pole, 70 °C 85 A | |
| (440 V) 1-Pole, 40 °C 100 A | |
| (440 V) 1-Pole, 55 °C 100 A | |
| (440 V) 1-Pole, 70 °C 85 A | |
| (600 V) 1-Pole, 40 °C 75 A | |
| (600 V) 1-Pole, 55 °C 75 A | |
| (600 V) 1-Pole, 70 °C 75 A | |
| (72 V) 1-Pole, 40 °C 120 A | |
| (72 V) 1-Pole, 55 °C 100 A | |
| (72 V) 1-Pole, 70 °C 85 A | |
| Rated Operational Current DC-3 (Ie) | (110 V) 1-Pole, 40 °C 120 A |
| (110 V) 1-Pole, 55 °C 100 A | |
| (220 V) 1-Pole, 40 °C 100 A | |
| (220 V) 1-Pole, 55 °C 100 A | |
| (440 V) 1-Pole, 40 °C 85 A | |
| (440 V) 1-Pole, 55 °C 85 A | |
| (72 V) 1-Pole, 40 °C 120 A | |
| (72 V) 1-Pole, 55 °C 100 A | |
| Rated Operational Current DC-5 (Ie) | (110 V) 1-Pole, 40 °C 85 A |
| (110 V) 1-Pole, 55 °C 85 A | |
| (220 V) 1-Pole, 40 °C 85 A | |
| (220 V) 1-Pole, 55 °C 85 A | |
| (440 V) 1-Pole, 40 °C 35 A | |
| (440 V) 1-Pole, 55 °C 35 A | |
| (72 V) 1-Pole, 40 °C 85 A | |
| (72 V) 1-Pole, 55 °C 85 A | |
| Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W |
| (48 V) 2.8 A / 134 W | |
| (72 V) 1 A / 72 W | |
| (110 V) 0.55 A / 60 W | |
| (125 V) 0.55 A / 69 W | |
| (220 V) 0.30 A / 66 W | |
| (250 V) 0.3 / 75 W | |
| Short-Circuit Protective Devices | Auxiliary Circuit - gG Type Fuses 10 A |
| gG Type Fuses 160 A | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 140 A |
| for 1 s 100 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 1000 V |
| acc. to IEC 60947-5-1 690 V | |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Maximum Electrical Switching Frequency | 300 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Minimum Switching Capacity | 17 / 5 VLT4K |
| Rated Control Circuit Voltage (Uc) | DC Operation 220 V |
| Coil Consumption | Average Holding Value, from Warm State 4 W |
| Average Pull-in Value, from Cold State 200 W | |
| Holding at Max. Rated Control Circuit Voltage 50 Hz 4 W | |
| Holding at Max. Rated Control Circuit Voltage DC 4 W | |
| Pull-in at Max. Rated Control Circuit Voltage DC 200 V·A | |
| Power Loss | at Rated Operating Conditions per Pole 0.1 W |
| at 6 A per Pole 0.1 W | |
| Operate Time | Between Coil De-energization and NC Contact Closing 8 ... 18 ms |
| Between Coil De-energization and NO Contact Opening 5 ... 15 ms | |
| Between Coil Energization and NC Contact Opening 10 ... 27 ms | |
| Between Coil Energization and NO Contact Closing 30 ... 30 ms | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied) | 2 x M6 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Cable End 6 ... 16 mm² |
| Rigid Cable 6 ... 25 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Cable End 0.75 ... 2.5 mm² |
| Rigid Cable 1 ... 4 mm² | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| Connecting Terminals (delivered in open position) Main Poles | M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 1000 V DC |
| General Use Rating UL/CSA | (1000 V DC) 35 A |
| (440 V DC) 100 A | |
| (600 V DC) 75 A | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C |
| Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C | |
| Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C | |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| Certificates and Declarations | |
| CB Certificate | CB_CN45325 |
| CCC Certificate | CCC_2018010304129268 |
| CQC Certificate | CQC2018010304129268 |
| CSA Certificate | CSA_1033838_LR056745 |
| Declaration of Conformity - CCC | 2020980304001625 |
| Declaration of Conformity - CE | 1SBD250807U1000 |
| Declaration of Conformity - UKCA | 1SBD250824U1000 |
| EAC Certificate | EAC_RU C-FR ME77 B03599 |
| UL Listing Card | UL_E319322 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 140 mm |
| Package Level 1 Depth / Length | 146 mm |
| Package Level 1 Height | 96 mm |
| Package Level 1 Gross Weight | 1.3 kg |
| Package Level 1 EAN | 3471522113887 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC002552 - Power contactor, DC switching |
| ETIM 8 | EC002552 - Power contactor, DC switching |
| ETIM 9 | EC002552 - Power contactor, DC switching |
| eClass | V11.0 : 27371018 |
| UNSPSC | 39121529 |