GA75-10-11 1SBL411025R5311 ABB GA75-10-11 440V 50Hz / 500V 60Hz Contactor
GA75-10-11
1SBL411025R5311
ABB
1 Pcs.
Automation > Power contactor, DC switching
"A" FRCTLP
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb GA75-10-11 Contactor functions as an electromechanical switching device designed to manage heavy electrical loads in industrial power circuits. Technicians deploy high-capacity contactors within motor control centers and automation systems to reliably start, stop, and switch high-current loads.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Number of Main Contacts NO: 1
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 1
- Rated Operational Voltage: Main Circuit 600 V
- Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
- Rated Operational Current AC-15 (I e ): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 160 A
- Maximum Electrical Switching Frequency: 300 cycles per hour
- Rated Operational Current DC-1 (I e ): (440 V) 55 °C 100 A
- Rated Operational Current DC-3 (I e ): (440 V) 85 A
- Rated Operational Current DC-5 (I e ): (220 V) 85 A (440 V) 35 A
- Rated Operational Current DC-13 (I e ): (125 V) 0.55 / 69 A (24 V) 6 / 144 A (250 V) 0.3 / 75 A (48 V) 2.8 / 134 A (72 V) 1 / 72 A
- Rated Impulse Withstand Voltage (U imp ): 8 kV
- Mechanical Durability: 10 million
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
More info
▲GA75 contactors are designed for DC circuit switching. Arc suppression is more difficult in DC than in AC. To choose a contactor, it is necessary to know the current and voltage to be broken as well as the L/R time constant of the power circuit to be controlled. GA75 contactors are of the block type design. - Main poles: the contactors are fitted with arc chutes with permanent magnets specially designed for DC breaking. The three contactor paths are arranged in series via two supplied and fitted insulated connections (25 mm²). The GA75 are "single-pole" devices for which the connection polarities indicated next to the connection terminals must be respected. Furthermore, they are marked 1L1 for the positive terminal and 2T1 for the negative terminal. - Auxiliary contact: 1 CAL 5-11 side-mounted add-on auxiliary contact block (GA75-10-11 types) - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available
Ordering
- EAN:
- 3471522100535
- Minimum Order Quantity:
- 1 piece
- Customs Tariff Number:
- 85369085
Dimensions
- Product Net Width:
- 82mm
- Product Net Depth:
- 108mm
- Product Net Height:
- 132mm
- Product Net Weight:
- 1.260kg
Container Information
- Package Level 1 Units:
- 1 piece
- Package Level 1 Width:
- 140 mm
- Package Level 1 Length:
- 146 mm
- Package Level 1 Height:
- 96 mm
- Package Level 1 Gross Weight:
- 1.26 kg
- Package Level 1 EAN:
- 3471522100535
- Package Level 2 Units:
- 63 piece
Technical
- Number of Main Contacts NO:
- 1
- Number of Main Contacts NC:
- 0
- Number of Auxiliary Contacts NO:
- 1
- Number of Auxiliary Contacts NC:
- 1
- Rated Operational Voltage:
- Main Circuit 600 V
- Rated Frequency (f):
- Supply Circuit 50 Hz
Supply Circuit 60 Hz
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors q = 40 °C 125 A
acc. to IEC 60947-5-1, q = 40 °C 16 A
- Rated Operational Current AC-15 (Ie):
- (220 / 240 V) 4 A
(24 / 127 V) 6 A
(380 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
- Short-Circuit Protective Devices:
- Auxiliary Circuit - gG Type Fuses 10 A
gG Type Fuses 160 A
- Rated Short-time Withstand Current (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
for 0.1 s 140 A
for 1 s 100 A
- Maximum Electrical Switching Frequency:
- 300 cycles per hour
- Rated Operational Current DC-1 (Ie):
- (440 V) 55 °C 100 A
- Rated Operational Current DC-3 (Ie):
- (440 V) 85 A
- Rated Operational Current DC-5 (Ie):
- (220 V) 85 A
(440 V) 35 A
- Rated Operational Current DC-13 (Ie):
- (125 V) 0.55 / 69 A
(24 V) 6 / 144 A
(250 V) 0.3 / 75 A
(48 V) 2.8 / 134 A
(72 V) 1 / 72 A
- Rated Insulation Voltage (Ui):
- acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
acc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp):
- 8 kV
- Mechanical Durability:
- 10 million
- Maximum Mechanical Switching Frequency:
- 3600 cycles per hour
- Coil Operating Limits:
- (acc. to IEC 60947-4-1)0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C
- Rated Control Circuit Voltage (Uc):
- 50 Hz 440 V
60 Hz 500 V
- Coil Consumption:
- Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 210 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 18 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 W
Holding at Max. Rated Control Circuit Voltage 50 Hz 18 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 W
Average Holding Value 50 / 60 Hz 18 V·A
Average Holding Value 50 / 60 Hz 5.5 W
Average Pull-in Value 50 Hz 180 V·A
Average Pull-in Value 60 Hz 210 V·A
- Operate Time:
- Between Coil Energization and NO Contact Closing 8 ... 27 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil De-energization and NC Contact Closing 7 ... 14 ms
Between Coil Energization and NC Contact Opening 7 ... 22 ms
- Connecting Capacity-Main Circuit:
- Flexible with Cable End6 ... 16 mm²
Rigid Cable6 ... 25 mm²
- Connecting Capacity-Auxiliary Circuit:
- Flexible with Cable End0.75 ... 2.5 mm²
Rigid Cable1 ... 4 mm²
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
- Connecting terminals (delivered in open position) Main poles:
- M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
- Terminal Type:
- Screw Terminals
Environmental
- Ambient Air Temperature:
- Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C
Near Contactor for Operation in Free Air (Uc) -40 ... +70 °C
Close to Contactor for Storage -60 ... +80 °C
- Climatic Withstand:
- acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
- Maximum Operating Altitude Permissible:
- 3000 m
- RoHS Status:
- No declaration needed
Certificates and Declarations (Document Number)
- CCC Certificate:
- CCC_2011010304454200
- CSA Certificate:
- CSA_1033838_LR056745
- Declaration of Conformity - CE:
- 1SBD250815C2000
- GOST Certificate:
- GOST_POCCFRME77B07175
- RoHS Information:
- 1SBC101059D0201
Classifications
- ETIM 5:
- EC002552 - Power contactor, DC switching
- UNSPSC:
- 39121529