ABB 1SBL411025R8411 1SBL411025R8411 ABB GA75-10-11 110V 50Hz / 110-120V 60Hz Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SBL411025R8411 ABB GA75-10-11 110V 50Hz / 110-120V 60Hz Contactor

1SBL411025R8411

411025

ABB

1 Pcs.

GA75-10-11 110V 50Hz / 110-120V 60Hz Contactor GA75-10-11 CONT. DC cut BOB.110V 50Hz

Automation > Power contactor, DC switching
"A" FRCTLP

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information1SBC100214C0202
Instructions and ManualsFPTC407691P0003
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width82 mm
Product Net Depth / Length108 mm
Product Net Height132 mm
Product Net Weight1.26 kg
Technical
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Rated Operational VoltageAuxiliary Circuit 690 V
Main Circuit 1000 V DC
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
Rated Operational Current DC-1 (Ie)(1000 V) 1-Pole, 40 °C 35 A
(1000 V) 1-Pole, 55 °C 35 A
(1000 V) 1 Pole, 70 °C 35 A
(110 V) 1-Pole, 40 °C 120 A
(110 V) 1-Pole, 55 °C 100 A
(110 V) 1-Pole, 70 °C 85 A
(220 V) 1-Pole, 40 °C 120 A
(220 V) 1-Pole, 55 °C 100 A
(220 V) 1-Pole, 70 °C 85 A
(440 V) 1-Pole, 40 °C 100 A
(440 V) 1-Pole, 55 °C 100 A
(440 V) 1-Pole, 70 °C 85 A
(600 V) 1-Pole, 40 °C 75 A
(600 V) 1-Pole, 55 °C 75 A
(600 V) 1-Pole, 70 °C 75 A
(72 V) 1-Pole, 40 °C 120 A
(72 V) 1-Pole, 55 °C 100 A
(72 V) 1-Pole, 70 °C 85 A
Rated Operational Current DC-3 (Ie)(110 V) 1-Pole, 40 °C 120 A
(110 V) 1-Pole, 55 °C 100 A
(220 V) 1-Pole, 40 °C 100 A
(220 V) 1-Pole, 55 °C 100 A
(440 V) 1-Pole, 40 °C 85 A
(440 V) 1-Pole, 55 °C 85 A
(72 V) 1-Pole, 40 °C 120 A
(72 V) 1-Pole, 55 °C 100 A
Rated Operational Current DC-5 (Ie)(110 V) 1-Pole, 40 °C 85 A
(110 V) 1-Pole, 55 °C 85 A
(220 V) 1-Pole, 40 °C 85 A
(220 V) 1-Pole, 55 °C 85 A
(440 V) 1-Pole, 40 °C 35 A
(440 V) 1-Pole, 55 °C 35 A
(72 V) 1-Pole, 40 °C 85 A
(72 V) 1-Pole, 55 °C 85 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 1.1 A / 121 W
(125 V) 0.55 A / 69 W
(220 V) 0.30 A / 66 W
(250 V) 0.3 / 75 W
Short-Circuit Protective DevicesAuxiliary Circuit - gG Type Fuses 10 A
gG Type Fuses 160 A
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A
for 1 s 100 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 1000 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Maximum Electrical Switching Frequency300 cycles per hour
Mechanical Durability10 million
Maximum Mechanical Switching Frequency3600 cycles per hour
Minimum Switching Capacity17 / 5 VLT4K
Rated Control Circuit Voltage (Uc)50 Hz 110 V
60 Hz 110 ... 120 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 18 V·A
Average Pull-in Value 50 Hz 190 V·A
Average Pull-in Value 60 Hz 180 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 18 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 W
Holding at Max. Rated Control Circuit Voltage 60 Hz 18 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 210 V·A
Power Lossat Rated Operating Conditions per Pole 0.1 W
at 6 A per Pole 0.1 W
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 14 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 7 ... 22 ms
Between Coil Energization and NO Contact Closing 8 ... 27 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M6 Screws Placed Diagonally
Connecting Capacity Main CircuitFlexible with Cable End 6 ... 16 mm²
Rigid Cable 6 ... 25 mm²
Connecting Capacity Auxiliary CircuitFlexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main PolesM 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
Terminal TypeScrew Terminals
Product NameBlock Contactor
Technical UL/CSA
Maximum Operating Voltage UL/CSAMain Circuit 1000 V DC
General Use Rating UL/CSA(1000 V DC) 35 A
(440 V DC) 100 A
(600 V DC) 75 A
Environmental
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C
Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstandacc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
CB CertificateCB_CN45325
CCC CertificateCCC_2018010304129268
CQC CertificateCQC2018010304129268
CSA CertificateCSA_1033838_LR056745
Declaration of Conformity - CCC2020980304001625
Declaration of Conformity - CE1SBD250807U1000
Declaration of Conformity - UKCA1SBD250824U1000
EAC CertificateEAC_RU C-FR ME77 B03599
UL Listing CardUL_E319322
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width140 mm
Package Level 1 Depth / Length146 mm
Package Level 1 Height96 mm
Package Level 1 Gross Weight1.26 kg
Package Level 1 EAN3471522100849
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC002552 - Power contactor, DC switching
ETIM 8EC002552 - Power contactor, DC switching
ETIM 9EC002552 - Power contactor, DC switching
eClassV11.0 : 27371018
UNSPSC39121529
IDEA Granular Category Code (IGCC)4763 >> Power contactor, DC switching

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.