ABB 2CCL564111E0203 2CCL564111E0203 ABB FS403E-C20/0.03 Residual Current Circuit Breaker with overcurrent Protection 3PN,C20A,30.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

2CCL564111E0203 ABB FS403E-C20/0.03 Residual Current Circuit Breaker with overcurrent Protection 3PN,C20A,30..

2CCL564111E0203

564111

ABB

1 Pcs.

FS403E-C20/0.03 Residual Current Circuit Breaker with overcurrent Protection 3PN,C20A,30mA,6kA SMISSLINE SMISSLINE-I.Com FS403E C 20A 30mA FS403E-C20/0.03

Automation > Earth leakage circuit breaker
SMISSLINE

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

ABB EcoSolutions
EcoSolutions Profile9AKK108470A5866
Technical
Type of Residual CurrentType A
Dielectric Test Voltage2500 kV
Rated Operational Current (Ie)20 A
Rated Residual Breaking Capacity (IΔm)6000 A
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)6 kA
Maximum Surge Current0.25 kA
Contact Position IndicationRed ON / Green OFF
Energy Limiting Class3
Electrical Endurance10000 cycle
Mechanical Endurance10000 cycle
Number of Protected Poles3
Number of Poles4P
Operating CharacteristicInstantaneous
Position of Neutral TerminalsRight
Tightening Torque2.8 N·m
Actuator TypeToggle
Earthing Switch TypeUndelayed
Screw Terminal TypeFailsafe Bi-directional Cylinder-lift Terminal
Actuator MaterialInsulation Group II, Black, Sealable
Accessories AvailableYes
Connecting CapacityStranded 0.75 ... 35 mm²
Flexible 0.75 ... 25 mm²
Rated Cross-Section1 - Solid-Core 0.75 … 35 mm²
4 - Multi-Wired 0.75 … 10 mm²
Electrical
Short-Circuit Current Rating (SCCR)0.03 A
Tripping CharacteristicC
Rated Operational Voltageacc. to IEC 60898-1 415 V
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 500 V
Rated Impulse Withstand Voltage (Uimp)4 kV
Input Voltage TypeAC
Rated Current (In)20 A
Rated Residual Current30 mA
Rated Short-Circuit Capacity6 kA
Rated Frequency (f)50 … 60 Hz
Power Loss7.5 W
Overvoltage CategoryIII
Design
Housing MaterialInsulation Group I, RAL 7035
Material Compliance
RoHS Declaration2CCC413008D0206_RoHS
RoHS InformationFollowing EU Directive 2002/95/EC August 18, 2005 and amendment
RoHS Date20170426
REACH Declaration9AKK108467A9561
REACH InformationTrue - contains substances > 0.1 mass percentage
REACH Date20230417
Conflict Minerals Reporting Template (CMRT)9AKK108468A3363
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2BBusiness To Business
Environmental
Ambient Air TemperatureOperation -25 … 60 °C
Reference Ambient Air Temperature30 °C
Degree of ProtectionIP20
Pollution Degree2
Resistance to Vibrations1 mm 2 … 13.2 Hz
Environmental Information9AKK108467A9561
Dimensions
Width in Number of Modular Spacings3
Product Net Width72 mm
Product Net Height91 mm
Product Net Depth / Length75 mm
Product Net Weight410 g
Built-In Depth (t2)91 mm
Dimension Diagram9AKK107492A6192
Engineering
EPLAN Data9AAC167708_EPLAN
Ordering
Package Level 1 Unitscarton 1 piece
Package Level 1 Gross Weight466 g
E-Number (Norway)1628533
E-Number (Switzerland)809180839
Replacement Product ID (NEW)2CCG001722R0001
Certificates and Declarations
Declaration of Conformity - CE2CCC451036D0201
Installation
Instructions and Manuals9AKK107680A1664
Mounting PositionAny
Popular Downloads
Data Sheet, Technical Information9AKK107492A6192
External Classifications and Standards
ETIM 9EC000905 - Earth leakage circuit breaker
eClassV11.0 : 27142207
Object Classification CodeFB
StandardsIEC 61009-1
EN 61009-1
DIN EN 61009-1
EN 61009-2-1
DIN EN 61009-2-1

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.