View larger
2CCL562111E0135 ABB FS401E-B13/0,03 Residual Current Circuit Breaker with overcurrent Protection 2 Poles B C..
2CCL562111E0135
562111
ABB
1 Pcs.
Automation > Earth leakage circuit breaker
SMISSLINE
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb 2CCL562111E0135 residual current circuit breaker with overcurrent protection is built to guard industrial and commercial circuits against overloads, short circuits, and dangerous residual currents. Panel builders specify these combination devices to achieve reliable circuit isolation and maintain strict workplace safety. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- EcoSolutions Profile: 9AKK108470A5866
- Type of Residual Current: Type A
- Dielectric Test Voltage: 2500 kV
- Rated Operational Current (I e ): 13 A
- Rated Residual Breaking Capacity (IΔm): 6000 A
- Maximum Surge Current: 0.25 kA
- Contact Position Indication: Red ON / Green OFF
- Energy Limiting Class: 3
- Electrical Endurance: 10000 cycle
- Mechanical Endurance: 10000 cycle
- Number of Protected Poles: 1
- Number of Poles: 2P
- Operating Characteristic: Instantaneous
- Position of Neutral Terminals: Right
- Tightening Torque: 2.8 N·m
- Actuator Type: Toggle
More info
▲| ABB EcoSolutions | |
|---|---|
| EcoSolutions Profile | 9AKK108470A5866 |
| Technical | |
| Type of Residual Current | Type A |
| Dielectric Test Voltage | 2500 kV |
| Rated Operational Current (Ie) | 13 A |
| Rated Residual Breaking Capacity (IΔm) | 6000 A |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 6 kA |
| Maximum Surge Current | 0.25 kA |
| Contact Position Indication | Red ON / Green OFF |
| Energy Limiting Class | 3 |
| Electrical Endurance | 10000 cycle |
| Mechanical Endurance | 10000 cycle |
| Number of Protected Poles | 1 |
| Number of Poles | 2P |
| Operating Characteristic | Instantaneous |
| Position of Neutral Terminals | Right |
| Tightening Torque | 2.8 N·m |
| Actuator Type | Toggle |
| Earthing Switch Type | Undelayed |
| Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
| Actuator Material | Insulation Group II, Black, Sealable |
| Accessories Available | Yes |
| Connecting Capacity | Stranded 0.75 ... 35 mm² |
| Flexible 0.75 ... 25 mm² | |
| Rated Cross-Section | 1 - Solid-Core 0.75 … 35 mm² |
| 4 - Multi-Wired 0.75 … 10 mm² | |
| Electrical | |
| Short-Circuit Current Rating (SCCR) | 0.03 A |
| Tripping Characteristic | B |
| Rated Operational Voltage | acc. to IEC 60898-1 240 V |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 500 V |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Input Voltage Type | AC |
| Rated Current (In) | 13 A |
| Rated Residual Current | 30 mA |
| Rated Short-Circuit Capacity | 6 kA |
| Rated Frequency (f) | 50 … 60 Hz |
| Power Loss | 2.3 W |
| Overvoltage Category | III |
| Design | |
| Housing Material | Insulation Group I, RAL 7035 |
| Material Compliance | |
| RoHS Declaration | 2CCC413008D0206_RoHS |
| RoHS Information | Following EU Directive 2002/95/EC August 18, 2005 and amendment |
| RoHS Date | 20170426 |
| REACH Declaration | 9AKK108467A9561 |
| REACH Information | True - contains substances > 0.1 mass percentage |
| REACH Date | 20230417 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Business |
| Environmental | |
| Ambient Air Temperature | Operation -25 … 60 °C |
| Reference Ambient Air Temperature | 30 °C |
| Degree of Protection | IP20 |
| Pollution Degree | 2 |
| Resistance to Vibrations | 1 mm 2 … 13.2 Hz |
| Environmental Information | 9AKK108467A9561 |
| Dimensions | |
| Width in Number of Modular Spacings | 1 |
| Product Net Width | 36 mm |
| Product Net Height | 91 mm |
| Product Net Depth / Length | 78 mm |
| Product Net Weight | 200 g |
| Built-In Depth (t2) | 91 mm |
| Dimension Diagram | 9AKK107492A6192 |
| Engineering | |
| EPLAN Data | 9AAC128469_EPLAN |
| Ordering | |
| Package Level 1 Units | carton 1 piece |
| Package Level 1 Gross Weight | 239 g |
| E-Number (Norway) | 1623561 |
| E-Number (Switzerland) | 809029839 |
| Replacement Product ID (NEW) | 2CCG001657R0001 |
| Certificates and Declarations | |
| Declaration of Conformity - CE | 2CCC451036D0201 |
| Installation | |
| Instructions and Manuals | 9AKK107680A1664 |
| Mounting Position | Any |
| Popular Downloads | |
| Data Sheet, Technical Information | 9AKK107492A6192 |
| External Classifications and Standards | |
| ETIM 9 | EC000905 - Earth leakage circuit breaker |
| eClass | V11.0 : 27142207 |
| Object Classification Code | FB |
| Standards | IEC 61009-1 |
| EN 61009-1 | |
| DIN EN 61009-1 | |
| EN 61009-2-1 | |
| DIN EN 61009-2-1 | |