ABB 2CCF544110E0630 2CCF544110E0630 ABB F404A63/0.03 3PN,63A,30mA SMISSLINE View larger
Images are for illustrative purposes only. Please refer to data sheet for details

2CCF544110E0630 ABB F404A63/0.03 3PN,63A,30mA SMISSLINE

2CCF544110E0630

544110

ABB

1 Pcs.

F404A63/0.03 3PN,63A,30mA SMISSLINE SMISSLINE-I. Diff.F404A63/0.03 Smissline F400 Differential Switch - 4P - 30 mA - 63 A - Type A

Automation > Residual current circuit breaker (RCCB)
SMISSLINE

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

F404A63/0.03 3PN,63A,30mA SMISSLINE

Ordering

  • EAN:
    7612270104291
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85363020

Dimensions

  • Product Net Width:
    91mm
  • Product Net Height:
    97mm
  • Product Net Length:
    72 mm
  • Product Net Depth:
    72mm
  • Product Net Weight:
    0.43kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    101 mm
  • Package Level 1 Height:
    89 mm
  • Package Level 1 Length:
    76 mm
  • Package Level 1 Gross Weight:
    0.49 kg
  • Package Level 1 EAN:
    7612270104291

Environmental

  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Additional Information

  • IIT Publishing Status:
    Level 0 - Information enabled
  • Power Loss:
    4.4 W
  • Product Main Type:
    F404
  • Product Name:
    F404
  • Rated Operational Current (Ie):
    63 A
  • Rated Operational Voltage:
    230 / 400 V AC
  • Rated Residual Current:
    0.03_AMPx
  • Rated Voltage (Ur):
    230 / 400 V
  • Standards:
    EN 61008-1

Certificates and Declarations (Document Number)

Classifications

  • ETIM 4:
    EC002297 - Residual current circuit breaker (RCCB) module
  • ETIM 5:
    EC002297 - Residual current circuit breaker (RCCB) module
  • Object Classification Code:
    FB

ETIM for 2CCF544110E0630 Circuit breakers and fuses (EC000003)
Feature Name Feature Value
Number of poles (EF001391) 4
Rated voltage (EF000228) 400 V
Rated current (EF000227) 63 A
Rated fault current (EF002358) 0.03 A
Rated insulation voltage Ui (EF001366) 500 V
Rated impulse withstand voltage Uimp (EF011980) 4 kV
Mounting method (EF000003) Other
Leakage current type (EF002560) A
Selective protection (EF002561) No
Short-time delayed tripping (EF003604) No
Short-circuit breaking capacity (Icw) (EF002562) 1 kA
Surge current capacity (EF002564) 0.25 kA
With interlocking device (EF007385) Yes
Frequency (EF005455) Other
Additional equipment possible (EF008148) Yes
Degree of protection (IP) (EF005474) IP20
Width in number of modular spacings (EF002950) 4
Built-in depth (EF000218) 69 mm
Ambient temperature during operating (EF007515) -25 °C
Pollution degree (EF002570) 2
Connectable conductor cross section multi-wired (EF007343) 0 mm²
Connectable conductor cross section solid-core (EF007337) 0 mm²
Explosion-proof (EF004663) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.