View larger
ESB24-40/230V
GHE3291102R0006
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC103051C0201 |
| Instructions and Manuals | 2CDC103025M6801 |
| Dimensions | |
| Product Net Width | 36 mm |
| Product Net Depth / Length | 65 mm |
| Product Net Height | 85 mm |
| Product Net Weight | 0.235 kg |
| Technical | |
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Poles | 4P |
| Standards | IEC/EN 60947-1 |
| IEC/EN 60947-4-1 | |
| IEC/EN 60947-5-1 | |
| IEC/EN 61095 | |
| UL 60947-1 | |
| UL 60947-4-1 | |
| Rated Operational Voltage | Main Circuit 220 V DC |
| Main Circuit 400 V AC | |
| Rated Frequency (f) | Control Circuit DC |
| Control Circuit 50 Hz | |
| Control Circuit 60 Hz | |
| Control Circuit 400 Hz | |
| Main Circuit DC | |
| Main Circuit 50 Hz | |
| Main Circuit 60 Hz | |
| Rated Operational Current AC-1 (Ie) | (NC) 24 A |
| (NO) 24 A | |
| Rated Operational Current AC-3 (Ie) | (230 V) Single Phase 9 A |
| (400 V) Three Phase 9 A | |
| Rated Operational Current AC-7a (Ie) | (NC) 24 A |
| (NO) 24 A | |
| Rated Operational Current AC-7b (Ie) | (230 V) Single Phase 9 A |
| (400 V) Three Phase 9 A | |
| Rated Operational Power AC-1 (Pe) | (230 V) Single Phase 5.5 kW |
| (400 V) Single Phase 16 kW | |
| Rated Operational Power AC-3 (Pe) | (230 V) Single Phase 1.3 kW |
| (400 V) Three Phase 4 kW | |
| Rated Operational Power AC-7a (Pe) | (230 V) Single Phase 5.5 kW |
| (400 V) Three Phase 16 kW | |
| Rated Operational Power AC-7b (Pe) | (230 V) Single Phase 1.3 kW |
| (400 V) Three Phase 4 kW | |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 500 V |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Electrical Durability | AC-1 150000 cycle |
| AC-3 500000 cycle | |
| AC-7a 150000 cycle | |
| AC-7b 500000 cycle | |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| (AC-3) 600 cycles per hour | |
| (AC-7a) 300 cycles per hour | |
| (AC-7b) 600 cycles per hour | |
| Mechanical Durability | Nr. Operations 1000000 cycle |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (Uc) | 230 ... 240 V |
| Coil Consumption | Average Holding Value 50 Hz 4 V·A |
| Average Pull-in Value 50 Hz 4 V·A | |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 3 W |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1x 1.5 ... 10 mm² |
| Flexible with Insulated Ferrule 1x 1.5 ... 10 mm² | |
| Flexible 1x 1.5 ... 10 mm² | |
| Rigid 1x 1.5 ... 10 mm² | |
| Rigid 2x 4 mm² | |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1x 0.75 ... 2.5 mm² |
| Flexible with Ferrule 2x 0.75 ... 1 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 1 mm² | |
| Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
| Flexible 1x 1 ... 4.0 mm² | |
| Flexible 2x 1 ... 2.5 mm² | |
| Rigid 1/2x 1 ... 4 mm² | |
| Rigid 2x 2.5 mm² | |
| Wire Stripping Length | Control Circuit 7 mm |
| Main Circuit 10 mm | |
| Degree of Protection | IP20 |
| Recommended Screw Driver | Control Circuit Pozidriv 1 |
| Main Circuit Pozidriv 1 | |
| Tightening Torque | Control Circuit 0.9 N·m |
| Main Circuit 1 N·m | |
| Terminal Type | Screw Terminals |
| Width in Number of Modular Spacings | 2.0 |
| Product Name | Installation Contactor |
| Remarks | Installation contactor, noiseless/humfree, high insulation, reliable function, long life |
| Technical UL/CSA | |
| General Use Rating UL/CSA | (acc. to UL 240 V) 24 A |
| (acc. to UL 480 V) 24 A | |
| Horsepower Rating UL/CSA | (220 ... 240 V AC) Single Phase 3 Hp |
| (440 ... 480 V AC) Three Phase 5 Hp | |
| Connecting Capacity Main Circuit UL/CSA | Stranded 16-8 AWG |
| Connecting Capacity Control Circuit UL/CSA | Stranded 16-10 AWG |
| Tightening Torque UL/CSA | Control Circuit 8 in·lb |
| Main Circuit 9 in·lb | |
| Full Load Amps Motor Use | (220 ... 240 V AC) Single Phase 9.6 A |
| (440 ... 480 V AC) Three Phase 7.6 A | |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +55 °C |
| Storage -40 ... +80 °C | |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 15g |
| Resistance to Vibrations | 5g 3 … 150 Hz |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Consumer |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| BV Certificate | 1SAA920000-0204 |
| CB Certificate | 1SAA920000-2003 |
| CQC Certificate | CQC2003010304064076 |
| Declaration of Conformity - CCC | 2020980304001308 |
| Declaration of Conformity - CE | 1SAD938513-0007 |
| DNV Certificate | 1SAA920000-0306 |
| EAC Certificate | 1SAA920000-2702 |
| KC Certificate | 1SAA920001-1501 |
| NF Certificate | 1SAA920000-1202 |
| RMRS Certificate | 1SAA920000-0705 |
| UL Certificate | E191658-19960301 |
| Container Information | |
| Package Level 1 Units | carton 5 piece |
| Package Level 1 Width | 89 mm |
| Package Level 1 Depth / Length | 183 mm |
| Package Level 1 Height | 69 mm |
| Package Level 1 Gross Weight | 1.22 kg |
| Package Level 1 EAN | 4013614420337 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC001653 - Installation contactor for distribution board |
| ETIM 8 | EC001653 - Installation contactor for distribution board |
| ETIM 9 | EC001653 - Installation contactor for distribution board |
| eClass | V11.0 : 27142308 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4759 >> Installation contactor for distribution board |
| E-Number (Finland) | 3709407 |