ABB SK827041-DF SK827041-DF ABB EK550-40-21 CONT. 4P 800A AC1 BOB.220Vcc View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SK827041-DF ABB EK550-40-21 CONT. 4P 800A AC1 BOB.220Vcc

SK827041-DF

SK827041DF

ABB

1 Pcs.

EK550-40-21 CONT. 4P 800A AC1 BOB.220Vcc EK550-40-21 220V DC Contactor

Automation > Power contactor, AC switching
Contactors and overload relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information1SBC100214C0202
Instructions and Manuals5309660-30
Dimensions
Product Net Width296 mm
Product Net Depth / Length225.5 mm
Product Net Height272 mm
Product Net Weight15.5 kg
Technical
Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC1
Number of Poles4P
Rated Operational VoltageMain Circuit 1000 V
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 800 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 800 A
(1000 V) 60 °C 650 A
(1000 V) 70 °C 575 A
(690 V) 40 °C 800 A
(690 V) 55 °C 650 A
(690 V) 60 °C 650 A
(690 V) 70 °C 575 A
Rated Operational Current AC-3 (Ie)(440 V) 55 °C 550 A
(500 V) 55 °C 550 A
(690 V) 55 °C 550 A
(1000 V) 55 °C 175 A
(380 / 400 V) 55 °C 550 A
(220 / 230 / 240 V) 55 °C 550 A
Rated Operational Power AC-3 (Pe)(415 V) 315 kW
(440 V) 315 kW
(500 V) 400 kW
(690 V) 500 kW
(1000 V) 35 kW
(380 / 400 V) 280 kW
(220 / 230 / 240 V) 160 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Short-Circuit Protective DevicesgG Type Fuses 1.5 ... 1.8 In A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 5300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 5500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3700 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
(AC-2 / AC-4) 120 cycles per hour
(AC-3) 300 cycles per hour
Mechanical Durability5 million
Maximum Mechanical Switching Frequency3600 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)DC Operation 220 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 125 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 140 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 3500 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 4000 V·A
Power Lossat Rated Operating Conditions per Pole 60 W
Operate TimeBetween Coil De-energization and NC Contact Closing 10 ... 20 ms
Between Coil De-energization and NO Contact Opening 13 ... 23 ms
Between Coil Energization and NC Contact Opening 25 ... 55 ms
Between Coil Energization and NO Contact Closing 30 ... 60 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Connecting Terminals (delivered in open position) Main PolesFlat type c/w screws and bolts
Terminal TypeMain Circuit: Bars
Product NameBlock Contactor
Technical UL/CSA
General Use Rating UL/CSA(600 V AC) 540 A
Environmental
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -50 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
SCIPd5ead741-b942-4645-b4db-5c0f7be52273 Bulgaria
Simplified SCIPadd6f9ad-cbdb-4660-8f70-216bd339b105 Germany
f81b80ba-648e-41e3-9792-bd5a6d8b9236 Germany
8dd7e4d0-16a9-47dd-932e-b0e712171e59 France
898bc35b-e427-477d-8873-3d258f91bc44 Spain
d4544449-002c-41e2-9f89-0c94ae61195c Belgium
87ad9099-c0f1-4e55-b055-dab591c263c0 Sweden
069afc4e-2de5-4022-955a-d687972e8f97 Denmark
0112bccf-0bc2-409a-812b-70bde300cf9e Croatia
771edfc6-1012-4232-a34f-bc8f5d828062 Estonia
185c27d6-b62d-4bda-b10c-3593d63ec6dc Sweden
ea533f34-9166-4b7c-8ac8-550b861e0dda Poland
3ccae9f7-88fd-4d31-b788-a8a27f319a96 Hungary
3e73d05f-d5b3-477e-a6f0-36f91a6b8127 Portugal
3bce118c-980e-425c-b1b0-fc3e2520311e Germany
2fe28e60-a673-4070-b31d-e2ec579fb35b France
263d842b-68ee-4d74-8c4c-29612d5b0c84 Czech Republic
39265d5a-9a9a-4eb3-9504-dc160c3cff4c Netherlands
b9fc1c38-89ca-4cd7-bbfa-2615578d30be Hungary
688c572d-2234-4945-bdf0-e8db2f86fcb3 Greece
db8a37d9-6538-441f-b759-9db1329ab0b9 Poland
d632040a-ac41-4a00-b885-bc293f0186a4 Finland
616e5093-577e-41d5-8320-b314edcb211f Belgium
42daa28a-065d-4c45-8b98-8bfa36c97ae0 Italy
a8e9d99f-02a1-4d43-bb47-7ea3df800525 Germany
4e426955-e872-4d12-90fd-8185d6f5c0d9 Norway
9f145b62-e146-4ac3-ac47-5f563706c4b1 Germany
a834d528-8dc8-462e-8273-7355b46ec9d5 Poland
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
CQC CertificateCQC2003010304094982
Declaration of Conformity - CCC2020980304001264
Declaration of Conformity - CE2CMT2015-005442
UL Certificate20161201-E36588
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width317 mm
Package Level 1 Depth / Length317 mm
Package Level 1 Height373 mm
Package Level 1 Gross Weight17.2 kg
Package Level 1 EAN7320500039557
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors

ETIM for SK827041-DF Low-voltage industrial controls and switchgear (EC000066)
Feature Name Feature Value
Rated control supply voltage DC (EF003980) 220 V
Voltage type for actuating (EF008242) DC
Rated operation current Ie at AC-1, 400 V (EF001393) 800 A
Rated operation current Ie at AC-3, 400 V (EF001392) 550 A
Rated operation power at AC-3, 400 V (EF001364) 280 kW
Modular version (EF001126) No
Number of auxiliary contacts as normally open contact (EF001376) 2
Number of auxiliary contacts as normally closed contact (EF001377) 1
Type of electrical connection of main circuit (EF006819) Rail connection
Number of normally closed contacts as main contact (EF001375) 0
Number of normally open contacts as main contact (EF001374) 4