ABB SK827044-AM SK827044-AM ABB EK1000-40-11 CONT. 4P BOB. 230-240V 50Hz View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SK827044-AM ABB EK1000-40-11 CONT. 4P BOB. 230-240V 50Hz

SK827044-AM

SK827044AM

ABB

1 Pcs.

EK1000-40-11 CONT. 4P BOB. 230-240V 50Hz EK1000-40-11 230-240V 50Hz Contactor

Automation > Power contactor, AC switching
Contactors and overload relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information1SBC100214C0202
Instructions and Manuals5309660-30
Dimensions
Product Net Width270 mm
Product Net Depth / Length225.5 mm
Product Net Height272 mm
Product Net Weight15.8 kg
Technical
Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles4P
Rated Operational VoltageMain Circuit 1000 V
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1000 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 1000 A
(1000 V) 60 °C 800 A
(1000 V) 70 °C 720 A
(690 V) 40 °C 1000 A
(690 V) 55 °C 800 A
(690 V) 60 °C 800 A
(690 V) 70 °C 720 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 6800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4400 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Mechanical Durability5 million
Maximum Mechanical Switching Frequency3600 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 230 ... 240 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 125 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 140 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 3500 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 4000 V·A
Power Lossat Rated Operating Conditions per Pole 80 W
Operate TimeBetween Coil De-energization and NC Contact Closing 10 ... 20 ms
Between Coil De-energization and NO Contact Opening 13 ... 23 ms
Between Coil Energization and NC Contact Opening 25 ... 55 ms
Between Coil Energization and NO Contact Closing 30 ... 60 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Connecting Terminals (delivered in open position) Main PolesFlat type c/w screws and bolts
Terminal TypeMain Circuit: Bars
Product NameBlock Contactor
Environmental
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -50 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
SCIPfaecd5c3-7ebf-4f70-bfcf-c0f094efd5f3 Bulgaria
Simplified SCIPfcee9c1e-0ea1-4c5e-9810-52e3ffac14b6 Croatia
4d2328a8-a46a-4fca-ba56-42de8a3728bd Germany
4482d59d-7bfc-425a-ba97-aa292e3cc08d Denmark
c5192216-ab4e-4c5f-86cb-a91ab963b690 Poland
4606b167-98f7-4a00-b06f-551fade27e1f Czech Republic
37220d44-4eec-47cc-87a7-09c8ff7d71a2 Belgium
5d87f5da-2aab-4eb7-a50d-35a672f8f9c6 Spain
2b37fb3f-de4c-4a0e-bd12-9e8beaae7ba8 France
cf008b1c-f944-4d8f-b65b-08370193906e Germany
b896950a-dc13-4a46-a995-80529543d990 Sweden
d2f5a33e-64db-4376-897a-35d028239d30 Norway
863ce6e1-85ea-4ef2-b706-1d3b536308c9 Poland
35557710-eff1-469b-a86e-fbde454e702a Germany
bb6ee0c8-db7c-47e7-a665-07cc0a2aa320 Portugal
87df817d-a43a-4507-86e6-fe19b9761c50 Germany
d3e39544-3e61-4ecd-a394-775817c3fca2 Hungary
71e5a212-6c2d-4479-840a-41d43994c41b Greece
998cab3b-a1d3-4ec8-948f-4887b64fd374 Netherlands
79d08151-a70f-4e49-a4e1-4697f65451a4 Hungary
d673ea01-818e-4a3d-9781-9008c3be5570 Finland
f404cc8f-473c-4a88-92c1-f382760468ba Belgium
82b71643-f3e0-42b6-87a2-20c50995a5e0 Italy
bcc8254b-d698-431c-bf8c-622f64816b77 Germany
178ad1b8-a03b-4970-98dc-dd2c007b2aa5 Estonia
2e8ae36a-439d-4654-82f0-2386ea42e3f2 Sweden
e43bcfa1-70c4-421c-84b1-2aa9d3a5041b Poland
cf00f8fa-c9cb-4c71-9b0f-23b7587f422f France
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
CQC CertificateCQC2003010304094983
Declaration of Conformity - CCC2020980304001285
Declaration of Conformity - CE2CMT2015-005442
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width317 mm
Package Level 1 Depth / Length373 mm
Package Level 1 Height234 mm
Package Level 1 Gross Weight17.5 kg
Package Level 1 EAN7320500194256
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors

ETIM for SK827044-AM Low-voltage industrial controls and switchgear (EC000066)
Feature Name Feature Value
Rated control supply voltage AC 50 Hz (EF003978) 230 V
Voltage type for actuating (EF008242) AC
Rated operation current Ie at AC-1, 400 V (EF001393) 1000 A
Modular version (EF001126) No
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as normally closed contact (EF001377) 1
Type of electrical connection of main circuit (EF006819) Rail connection
Number of normally closed contacts as main contact (EF001375) 0
Number of normally open contacts as main contact (EF001374) 4

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.