ABB SK827044-AL SK827044-AL ABB EK1000-40-11 CONT. 4P BOB. 230V 50Hz View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SK827044-AL ABB EK1000-40-11 CONT. 4P BOB. 230V 50Hz

SK827044-AL

SK827044AL

ABB

1 Pcs.

EK1000-40-11 CONT. 4P BOB. 230V 50Hz EK1000-40-11 220-230V 50Hz / 240V 60Hz Contactor

Automation > Power contactor, AC switching
Contactors and overload relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information1SBC100214C0202
Instructions and Manuals5309660-30
Dimensions
Product Net Width270 mm
Product Net Depth / Length225.5 mm
Product Net Height272 mm
Product Net Weight15.8 kg
Technical
Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles4P
Rated Operational VoltageMain Circuit 1000 V
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1000 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 1000 A
(1000 V) 60 °C 800 A
(1000 V) 70 °C 720 A
(690 V) 40 °C 1000 A
(690 V) 55 °C 800 A
(690 V) 60 °C 800 A
(690 V) 70 °C 720 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 6800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4400 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Mechanical Durability5 million
Maximum Mechanical Switching Frequency3600 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 220 ... 230 V
60 Hz 240 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 125 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 140 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 3500 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 4000 V·A
Power Lossat Rated Operating Conditions per Pole 80 W
Operate TimeBetween Coil De-energization and NC Contact Closing 10 ... 20 ms
Between Coil De-energization and NO Contact Opening 13 ... 23 ms
Between Coil Energization and NC Contact Opening 25 ... 55 ms
Between Coil Energization and NO Contact Closing 30 ... 60 ms
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Connecting Terminals (delivered in open position) Main PolesFlat type c/w screws and bolts
Terminal TypeMain Circuit: Bars
Product NameBlock Contactor
Environmental
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -50 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
SCIP694def48-96d5-4aca-89fd-a8a123d3933e Bulgaria
Simplified SCIP145323eb-bd73-43ef-81b8-205d1ebaef82 France
24d88e28-f4a8-4bc5-a7a9-ead58c8d1a96 Italy
305c0d58-8566-48ee-a6ba-0c941e651cc6 Germany
466d0735-bab0-45d6-ad2a-fc557fc319d6 Germany
4e32d6b5-77f8-408f-87b7-8ec28fdbd6ca Belgium
526b31e3-5d26-4dc2-a83a-679d792ec9b2 Hungary
64ac9452-7166-4bf1-9afc-a9fb7b6c1669 Poland
66f8630a-1896-412d-8bcc-74a9bb88a191 Sweden
6f92db1d-8a95-488a-8952-0d71ed61b10e France
7382e37d-5266-4163-b48c-cbcdd7f04baa Germany
749d8027-345c-4b81-b59e-707391325ed7 Portugal
78be4b69-8bd6-4640-bcf0-565d06ce51d3 Norway
7af8a190-5e7d-4b0a-bee6-e0bb60874cfb Czech Republic
82768028-9720-40ef-84b1-a25d4c7fca55 Estonia
9edfd9f6-cc31-4fe5-ba51-0cd6ce97eb25 Belgium
adbbd031-a514-468e-a1a5-1c5463b3acdc Greece
ae3f4ccb-3b59-48f8-a212-9897f160cac1 Finland
b21d5bc0-5d89-455c-8a90-f597aab7aeef Poland
b68f392f-3bb0-42db-adc2-3df5a1c35e3a Denmark
b8afcdf4-bd81-406b-9d9b-28889f48bdef Germany
bb339e83-8b9a-4e31-9d6e-2d3c6569d65a Netherlands
bffffc5d-eb39-40a4-b074-e6545c5938b2 Spain
c0b4e06d-021a-41b0-9897-507abf387ccd Germany
c372366e-2677-42db-ae48-4ab694cbd985 Hungary
d5c026d3-c698-438d-8448-880fa5f7a510 Sweden
e0ace2d2-361f-4403-8ba0-6fae745b265a Croatia
ef5dfc72-ab2c-428b-addc-0b01079c92e1 Poland
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
CQC CertificateCQC2003010304094983
Declaration of Conformity - CCC2020980304001285
Declaration of Conformity - CE2CMT2015-005442
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width317 mm
Package Level 1 Depth / Length373 mm
Package Level 1 Height234 mm
Package Level 1 Gross Weight17.5 kg
Package Level 1 EAN7320500194249
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors

ETIM for SK827044-AL Low-voltage industrial controls and switchgear (EC000066)
Feature Name Feature Value
Rated control supply voltage AC 50 Hz (EF003978) 220 V
Rated control supply voltage AC 60 Hz (EF003979) 240 V
Voltage type for actuating (EF008242) AC
Rated operation current Ie at AC-1, 400 V (EF001393) 1000 A
Modular version (EF001126) No
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as normally closed contact (EF001377) 1
Type of electrical connection of main circuit (EF006819) Rail connection
Number of normally closed contacts as main contact (EF001375) 0
Number of normally open contacts as main contact (EF001374) 4

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.