ABB 1SDA073226R1 1SDA073226R1 ABB E6.2V 4000 Ekip Touch LSIG 4p WMP View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SDA073226R1 ABB E6.2V 4000 Ekip Touch LSIG 4p WMP

1SDA073226R1

073226

ABB

1 Pcs.

E6.2V 4000 Ekip Touch LSIG 4p WMP

Automation > Power circuit-breaker for trafo/generator/installation protection
E6.2

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A withdrawable air circuit breaker, the 1SDA073226R1 ABB E6.2V 4000 Ekip Touch LSIG 4p WMP protects large-scale electrical networks from severe overcurrents and short-circuit faults. Such components are typically installed inside drawout switchgear configurations to allow safe maintenance isolation and system protection in industrial facilities.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • ABB EcoSolutions: Yes
  • Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 77 %
  • Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
  • End of Life Instructions: 9AKK108468A2364
  • Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
  • Toxic Substances Control Act - TSCA: 9AKK108467A8326
  • Environmental Product Declaration - EPD: 9AKK108468A1905
  • Environmental Information: 9AKK108467A6707
  • REACH Declaration: 9AKK108466A1425
  • RoHS Information: 9AKK108466A1424
  • RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
  • Order Code US and Canada: ZDVWERAF000A000000XX
  • EAN: 8015644770761
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85362090
  • Product Net Width: 929 mm

More info

▲
ABB EcoSolutions
ABB EcoSolutionsYes
Circular Value
Circular Design Principles Recyclability RateDesign for Closing Resource Loops - Standard EN45555 - 77 %
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
End of Life Instructions9AKK108468A2364
Group Waste to Landfill TargetUL 2799 Zero Waste To Landfill Validation available
Toxic Substances Control Act - TSCA9AKK108467A8326
Eco Transparency
Environmental Product Declaration - EPD9AKK108468A1905
9AKK108468A1913
Environmental
Environmental Information9AKK108467A6707
REACH Declaration9AKK108466A1425
RoHS Information9AKK108466A1424
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Ordering
Order Code US and CanadaZDVWERAF000A000000XX
EAN8015644770761
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width929 mm
Product Net Height425 mm
Product Net Depth / Length383 mm
Product Net Weight134 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width515 mm
Package Level 1 Height610 mm
Package Level 1 Depth / Length1127 mm
Package Level 1 Gross Weight143 kg
Package Level 1 EAN8015644770761
Additional Information
Current TypeAC
Electrical DurabilityUe =< 440 V 4000 cycle
Ue = 500 ... 690 V 4000 cycle
10 cycles per hour
Mechanical Durability12000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu])50 %
Number of Poles4
Power Loss544 W
Product Main TypeSACE Emax 2
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)100 %
Rated Current (In)4000 A
Rated Voltage (Ur)690 V
Rated Impulse Withstand Voltage (Uimp)acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui)AC 1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 150 kA
(230 V AC) 150 kA
(380 V AC) 150 kA
(400 V AC) 150 kA
(415 V AC) 150 kA
(440 V AC) 150 kA
(500 V AC) 130 kA
(660 V AC) 100 kA
(690 V AC) 100 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 100 kA
for 3 s 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 150 kA
(415 V AC) 150 kA
(440 V AC) 150 kA
(500 V AC) 130 kA
(525 V AC) 130 kA
(690 V AC) 100 kA
Rated Uninterrupted Current (Iu)4000 A
ReleaseEkip Touch LSIG
Release TypeEL
Short-Circuit Performance LevelV
StandardsIEC
Sub-typeE6.2
VersionW
CAD Dimensional Drawing1SDH001252R0289  
Certificates and Declarations
ATEX CertificateNo certification needed
CSA CertificateNo certification needed
CSA Certificate (Intrinsic Safe)No certification needed
Data Sheet, Technical Information1SDC200023D0209
Declaration of Conformity - CE9AKK106713A5544
UL CertificateNo certification needed
VDE CertificateNo certification needed
Mechanical Drawings1SDH001060R0105 
Wiring Diagram1SDM000091R0001
Instructions and Manuals1SDH001000R0002
Instructions and Manuals (Part 2)1SDH001316R1002
Classifications
ETIM 7EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 8EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification CodeQ
WEEE Category4. Large Equipment (Any External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Product Datasheet