View larger
1SDA071872R1
071872
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2364 |
| Environmental Product Declaration - EPD | 9AKK108468A1905 |
| 9AKK108468A1913 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 77 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 52b6e554-e3d2-4889-8408-b258d1ef2eb9 Italy |
| Simplified SCIP | 9fc29ed3-c21a-4112-a568-5b4dc83038b9 Belgium |
| 5c80cd91-2400-427f-95a3-e97735b6064b Spain | |
| 69cf7f01-1276-46e0-9880-517a234123d8 France | |
| 6e7471c3-2de6-4604-b70c-ad0158ff0f5b Hungary | |
| 69feaa1e-6c39-496b-bf48-12f3ca510295 Sweden | |
| ac0d302a-aa76-4522-b7e8-97b8f498d7de Germany | |
| 3a446227-4f16-4b7b-8d2c-4c6221050103 Germany | |
| db144a9e-8d55-47ae-9723-d4d5ecde5afa France | |
| 17382093-2307-4d8d-b5bf-fb7be2164305 Poland | |
| 7709ce5a-fe4a-49ba-8420-cd593470381a Croatia | |
| 0cfe9844-8605-404b-bea4-778b91dca5e5 Estonia | |
| 75bc488e-54d9-4b86-8204-b828bb07b23c Greece | |
| 595717b7-8a41-45f2-aa0d-a7382e1ff0c9 Portugal | |
| 8dca90f6-9229-4ae5-b1ad-640fa57e09f2 Bulgaria | |
| fc07fe11-d1c9-4722-8820-b33cef964c99 Sweden | |
| 45ba1435-1431-4ece-a903-a44f3980c7a1 Germany | |
| d5906286-f4a8-42a9-b9e3-bb76315dbcec Denmark | |
| e57dcda7-332b-46e5-a030-e82ed97782ae Germany | |
| 24fe2229-1436-4168-89ab-44432bcf2c51 Netherlands | |
| f385a145-8656-4ded-b68e-cfbce37b625a Poland | |
| 4305361d-0c86-4979-bfd8-7349977b273b Czech Republic | |
| 54f5fbda-b4fe-44f0-a814-77b4f270332a Hungary | |
| 693e468a-d60d-46d4-b1b1-dcfee2e4e9d2 Belgium | |
| a912bbf5-7b49-4049-9dad-d200cc82ebe0 Finland | |
| 490c5557-f552-499f-a54c-0b176640253e Poland | |
| 58907edb-c9a9-4e6b-853d-d539b4fd763a Norway | |
| d5ea7260-e914-44cf-9cdf-787931ebdd29 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZDVWERBB000A000000XX |
| EAN | 8015644757229 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 888 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 125 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 1127 mm |
| Package Level 1 Gross Weight | 134 kg |
| Package Level 1 EAN | 8015644757229 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0249 |
| Technical | |
| Connecting Capacity | 4000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 4000 cycle |
| Ue = 500 ... 690 V 4000 cycle | |
| 10 cycles per hour | |
| Mechanical Durability | 12000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 50 % |
| Number of Poles | 4P |
| Power Loss | 309 W |
| Rated Current (In) | 4000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 150 kA |
| (230 V AC) 150 kA | |
| (380 V AC) 150 kA | |
| (400 V AC) 150 kA | |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 130 kA | |
| (660 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 kA |
| for 3 s 100 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 150 kA |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 130 kA | |
| (525 V AC) 130 kA | |
| (690 V AC) 100 kA | |
| Rated Uninterrupted Current (Iu) | 4000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | V |
| Standards | IEC |
| Sub-type | E6.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5544 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001060R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |