View larger
1SDA071926R1
071926
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2364 |
| Environmental Product Declaration - EPD | 9AKK108468A1905 |
| 9AKK108468A1913 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 77 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 5997bd6c-7d4f-4420-abd3-5fb9bfeac9ad Italy |
| Simplified SCIP | fb8d84ab-ffec-4a62-8f7e-39f7621d130e Germany |
| 09a812cf-6d87-4791-bddb-a1215a8432b2 Belgium | |
| 5bfe6044-7ce2-437c-acd8-47c637d666ba Germany | |
| d47fb5c9-c63e-4670-8927-d0a671a2a7a7 France | |
| f1bdbb6c-5195-4320-8d9d-1a8a21b336bd Croatia | |
| 74ae4c8b-87f1-4ab9-a121-3f02e1a0c4dd Norway | |
| c2fbec5b-196c-4343-b72f-a854df03e127 Poland | |
| 3914c7c9-ec82-4022-b5e0-04d79b132267 Sweden | |
| bea7d2ba-7fd2-4fe0-8220-6fe45fc822c3 Poland | |
| c81eb84d-249d-42c4-a23a-93965bc8a2cd Finland | |
| 5c1e8a46-e08f-42e8-b4dd-b240d5b23473 Sweden | |
| d354182f-8dba-4e56-b0af-b71fec62dbdf Belgium | |
| 2f8f0c1c-4d86-49c8-9530-88d32a4de94a Czech Republic | |
| 4c943002-6a95-45e3-a954-06f357860749 Germany | |
| eb236fcf-7236-4b51-944b-9e291f1a23ef Poland | |
| d509d6c6-f8b1-4b4c-9f04-c97b06226db4 France | |
| 270f6c78-df21-4dcb-9d99-062e60a54ee5 Netherlands | |
| 03a50561-0d5e-4270-ba09-420b8b70c7ad Germany | |
| ac143af9-e033-4d75-9509-1f492724c84e Germany | |
| f5b3ba4e-58a3-45c3-8e54-ca578df9b793 Hungary | |
| cbe784e4-3902-4110-8982-775d850474fb Spain | |
| bf25a44b-0720-491c-b916-031abfce1e81 Hungary | |
| 9b095972-7ce5-4dd6-8072-6bce848818ec Estonia | |
| d92336eb-1487-440e-b24d-8db094a2a9e2 Greece | |
| 57b27cf0-0227-4609-af5f-3e7cd34edc1c Bulgaria | |
| bbf6f039-639b-4230-a318-76ebd17a5cff Portugal | |
| 15aa5991-b429-415f-8c9c-ec44df3d52ee Denmark | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZDHYETBF000A000000XX |
| EAN | 8015644757762 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 888 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 125 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 1127 mm |
| Package Level 1 Gross Weight | 134 kg |
| Package Level 1 EAN | 8015644757762 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0249 |
| Technical | |
| Connecting Capacity | 6000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 2000 cycle |
| Ue = 500 ... 690 V 2000 cycle | |
| 10 cycles per hour | |
| Mechanical Durability | 12000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 50 % |
| Number of Poles | 4P |
| Power Loss | 767 W |
| Rated Current (In) | 6300 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 kA |
| for 3 s 100 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (525 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Uninterrupted Current (Iu) | 6300 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E6.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5544 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001060R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 6300 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 100 kA |
| Overload release current setting (EF002336) | 2520.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 3780.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 9450.0 A |
| Integrated earth fault protection (EF007296) | Yes |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Back |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |