1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E6.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This ABB E6.2H 6300 Ekip Hi-Touch LSIG 4p WMP functions as an air circuit breaker engineered for high-capacity electrical distribution systems. Such hardware is commonly deployed in heavy industrial plants and commercial infrastructure to provide reliable main incoming protection, selective fault discrimination, and remote monitoring.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2364
- Environmental Product Declaration - EPD: 9AKK108468A1905
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 77 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 87f75555-d1b3-4ac8-80ad-2adc5d2d0c8f Italy
- Simplified SCIP: 92c01a72-dc24-4ba3-8a60-cc7b556b004a Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZDHYETAK000A000000XX
- EAN: 8015644771294
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2364 |
| Environmental Product Declaration - EPD | 9AKK108468A1905 |
| 9AKK108468A1913 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 77 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 87f75555-d1b3-4ac8-80ad-2adc5d2d0c8f Italy |
| Simplified SCIP | 92c01a72-dc24-4ba3-8a60-cc7b556b004a Germany |
| 1bc52354-9551-43f1-a581-ade6f5850bd7 Poland | |
| 7d75f62d-96fb-4cb9-a26e-94454415263b Poland | |
| e1071a52-ec5e-4a5c-b194-9558783adc2e Hungary | |
| bab7501b-4407-417d-bdd4-37c2ac5c3c55 Belgium | |
| c6e576f5-f9b9-4cdb-8a99-8fc414e1f5c8 Spain | |
| 25ef60d5-ea05-4ff0-9ac8-fd3a735b4978 France | |
| c35778e6-7ab8-4c30-948c-c1f512f983c1 Hungary | |
| 8cd5e451-9c31-468c-89d9-af8535e26732 Poland | |
| 845144d0-a9ec-43a3-9251-d4c4cff09e81 Czech Republic | |
| 53a9a93b-808b-4ec4-814a-d5db79faa741 Croatia | |
| 5bbe73e9-a1fa-4f8f-92ed-7aad3b1cb767 Germany | |
| bf02b587-1c53-49ac-8882-f59e018d117a Germany | |
| 61b1cb7a-b4ba-4642-ae79-e3fa5d2be39b Greece | |
| e9e14dc8-0d1e-4f2d-b752-c4d866b805ad Germany | |
| 49c26684-1dea-4612-9cb2-27485dd4fa13 Belgium | |
| c379b87b-e12d-4d75-9163-8285d3166aba Sweden | |
| bc465bfe-6d3c-4a34-912f-267c2f5f240a Denmark | |
| 4db919ed-ade3-4a99-a261-a23229d98dcf Germany | |
| f2126323-0e9a-4fda-b129-708f669b2a78 Finland | |
| 74e9ffd6-08a9-49c2-9a38-80ea4d5e3a57 Netherlands | |
| f3c6ded1-22eb-481a-ad3d-8e8fb76770d4 Norway | |
| b7f4531a-87c9-4024-899c-a8c0cd0abe71 Estonia | |
| 4638cd93-f541-47f4-a45b-df684f7357a2 France | |
| f2ef863a-64b7-460b-ab63-0ee2a73cd051 Portugal | |
| 686d322e-a293-4df8-b542-0b9c5215c1bc Sweden | |
| 9b3631f0-c58c-443d-92fb-aacfbc3ed415 Bulgaria | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZDHYETAK000A000000XX |
| EAN | 8015644771294 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 929 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 134 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 1127 mm |
| Package Level 1 Gross Weight | 143 kg |
| Package Level 1 EAN | 8015644771294 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0289 |
| Technical | |
| Connecting Capacity | 6000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 2000 cycle |
| Ue = 500 ... 690 V 2000 cycle | |
| 10 cycles per hour | |
| Mechanical Durability | 12000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 50 % |
| Number of Poles | 4P |
| Power Loss | 1550 W |
| Rated Current (In) | 6300 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 kA |
| for 3 s 100 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (525 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Uninterrupted Current (Iu) | 6300 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E6.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5544 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001060R0105 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |