ABB 1SDA073215R1 1SDA073215R1 ABB E6.2H 4000 Ekip Touch LSI 4p WMP View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SDA073215R1 ABB E6.2H 4000 Ekip Touch LSI 4p WMP

1SDA073215R1

073215

ABB

1 Pcs.

E6.2H 4000 Ekip Touch LSI 4p WMP

Automation > Power circuit-breaker for trafo/generator/installation protection
E6.2

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

ABB EcoSolutions
ABB EcoSolutionsYes
Circular Value
Circular Design Principles Recyclability RateDesign for Closing Resource Loops - Standard EN45555 - 77 %
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
End of Life Instructions9AKK108468A2364
Group Waste to Landfill TargetUL 2799 Zero Waste To Landfill Validation available
Toxic Substances Control Act - TSCA9AKK108467A8326
Eco Transparency
Environmental Product Declaration - EPD9AKK108468A1905
9AKK108468A1913
Environmental
Environmental Information9AKK108467A6707
REACH Declaration9AKK108466A1425
RoHS Information9AKK108466A1424
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP977d0027-f5d6-49fe-a492-437200e47beb Italy (IT)
Simplified SCIP579eaaec-be89-43a4-91a1-2850d04785c9 Germany (DE)
3aa5bcc7-648b-4ccb-b524-1fd30ffb74fc Estonia (EE)
091e044b-458e-4cd9-ab1a-22014b0da6c3 Belgium (BE)
4dc25cf7-5937-4ae3-8e98-be57bead8a75 Greece (GR)
e53730bb-17b2-4bdf-b196-5f9556f03c44 Germany (DE)
254a2b29-d626-4959-b73a-e75961bf5f69 Germany (DE)
4a131462-9cc4-43b0-b69c-9f312817c5f5 Denmark (DK)
5dc81f2a-97bf-4845-90c9-bc3e81306159 Germany (DE)
aad24c3b-1f64-4cff-8008-d57f19f32153 Germany (DE)
12e07079-2d0d-4a19-a2d5-e262f4e6583b France (FR)
132f63fd-dfb8-490a-aa60-ca22bddbdb8e Croatia (HR)
7eea5bef-5d65-4abd-a914-b5b2ba04aef6 France (FR)
e0ce4524-2ef4-437f-9205-b51f8785f292 Bulgaria (BG)
4f1f2265-2f23-467a-9d1b-81eed54f89a9 Sweden (SE)
aa0a9d10-1fcc-479e-917a-d9a42141d297 Portugal (PT)
53d83641-dfe5-48ae-95fe-65bf090ef17c Poland (PL)
15569514-6be6-472b-a4e3-95abe46307bd Poland (PL)
55f1d00c-0fb7-4099-8178-08e6751bb146 Netherlands (NL)
186deee0-b3a7-4db4-adf0-ddf9e488818a Sweden (SE)
b2efb7b0-3834-430c-933e-93d6d2798d7c Finland (FI)
118d54b5-50f3-479d-abf3-1359711594d8 Spain (ES)
54ba4c6b-4485-45f0-a036-d346fd1f90e6 Belgium (BE)
ff0ec6e4-2ef3-46c6-9c2e-58b9f57d676b Hungary (HU)
a06501df-413e-4596-8c80-0a50ad2b40db Norway (NO)
e18e1a59-ebc0-4dcf-a50e-a4647119c210 Hungary (HU)
7234ab2f-4dfe-4379-906d-561fca0e6295 Czech Republic (CZ)
eefcf481-4d0c-4ad9-a5a1-3c3b4950cc67 Poland (PL)
Ordering
Order Code US and CanadaZDHWERAE000A000000XX
EAN8015644770655
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width929 mm
Product Net Height425 mm
Product Net Depth / Length383 mm
Product Net Weight134 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width515 mm
Package Level 1 Height610 mm
Package Level 1 Depth / Length1127 mm
Package Level 1 Gross Weight143 kg
Package Level 1 EAN8015644770655
Additional Information
Current TypeAC
Electrical DurabilityUe =< 440 V 4000 cycle
Ue = 500 ... 690 V 4000 cycle
10 cycles per hour
Mechanical Durability12000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu])50 %
Number of Poles4
Power Loss544 W
Product Main TypeSACE Emax 2
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)100 %
Rated Current (In)4000 A
Rated Voltage (Ur)690 V
Rated Impulse Withstand Voltage (Uimp)acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui)AC 1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(660 V AC) 100 kA
(690 V AC) 100 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 100 kA
for 3 s 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(525 V AC) 100 kA
(690 V AC) 100 kA
Rated Uninterrupted Current (Iu)4000 A
ReleaseEkip Touch LSI
Release TypeEL
Short-Circuit Performance LevelH
StandardsIEC
Sub-typeE6.2
VersionW
CAD Dimensional Drawing1SDH001252R0289  
Certificates and Declarations
ATEX CertificateNo certification needed
CSA CertificateNo certification needed
CSA Certificate (Intrinsic Safe)No certification needed
Data Sheet, Technical Information1SDC200023D0209
Declaration of Conformity - CE9AKK106713A5544
UL CertificateNo certification needed
VDE CertificateNo certification needed
Mechanical Drawings1SDH001060R0105 
Wiring Diagram1SDM000091R0001
Instructions and Manuals1SDH001000R0002
Instructions and Manuals (Part 2)1SDH001316R1002
Classifications
ETIM 7EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 8EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification CodeQ
WEEE Category4. Large Equipment (Any External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.