View larger
1SDA073215R1
073215
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 77 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2364 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108468A1905 |
| 9AKK108468A1913 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 977d0027-f5d6-49fe-a492-437200e47beb Italy (IT) |
| Simplified SCIP | 579eaaec-be89-43a4-91a1-2850d04785c9 Germany (DE) |
| 3aa5bcc7-648b-4ccb-b524-1fd30ffb74fc Estonia (EE) | |
| 091e044b-458e-4cd9-ab1a-22014b0da6c3 Belgium (BE) | |
| 4dc25cf7-5937-4ae3-8e98-be57bead8a75 Greece (GR) | |
| e53730bb-17b2-4bdf-b196-5f9556f03c44 Germany (DE) | |
| 254a2b29-d626-4959-b73a-e75961bf5f69 Germany (DE) | |
| 4a131462-9cc4-43b0-b69c-9f312817c5f5 Denmark (DK) | |
| 5dc81f2a-97bf-4845-90c9-bc3e81306159 Germany (DE) | |
| aad24c3b-1f64-4cff-8008-d57f19f32153 Germany (DE) | |
| 12e07079-2d0d-4a19-a2d5-e262f4e6583b France (FR) | |
| 132f63fd-dfb8-490a-aa60-ca22bddbdb8e Croatia (HR) | |
| 7eea5bef-5d65-4abd-a914-b5b2ba04aef6 France (FR) | |
| e0ce4524-2ef4-437f-9205-b51f8785f292 Bulgaria (BG) | |
| 4f1f2265-2f23-467a-9d1b-81eed54f89a9 Sweden (SE) | |
| aa0a9d10-1fcc-479e-917a-d9a42141d297 Portugal (PT) | |
| 53d83641-dfe5-48ae-95fe-65bf090ef17c Poland (PL) | |
| 15569514-6be6-472b-a4e3-95abe46307bd Poland (PL) | |
| 55f1d00c-0fb7-4099-8178-08e6751bb146 Netherlands (NL) | |
| 186deee0-b3a7-4db4-adf0-ddf9e488818a Sweden (SE) | |
| b2efb7b0-3834-430c-933e-93d6d2798d7c Finland (FI) | |
| 118d54b5-50f3-479d-abf3-1359711594d8 Spain (ES) | |
| 54ba4c6b-4485-45f0-a036-d346fd1f90e6 Belgium (BE) | |
| ff0ec6e4-2ef3-46c6-9c2e-58b9f57d676b Hungary (HU) | |
| a06501df-413e-4596-8c80-0a50ad2b40db Norway (NO) | |
| e18e1a59-ebc0-4dcf-a50e-a4647119c210 Hungary (HU) | |
| 7234ab2f-4dfe-4379-906d-561fca0e6295 Czech Republic (CZ) | |
| eefcf481-4d0c-4ad9-a5a1-3c3b4950cc67 Poland (PL) | |
| Ordering | |
| Order Code US and Canada | ZDHWERAE000A000000XX |
| EAN | 8015644770655 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 929 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 134 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 1127 mm |
| Package Level 1 Gross Weight | 143 kg |
| Package Level 1 EAN | 8015644770655 |
| Additional Information | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 4000 cycle |
| Ue = 500 ... 690 V 4000 cycle | |
| 10 cycles per hour | |
| Mechanical Durability | 12000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 50 % |
| Number of Poles | 4 |
| Power Loss | 544 W |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Current (In) | 4000 A |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 kA |
| for 3 s 100 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (525 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Uninterrupted Current (Iu) | 4000 A |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E6.2 |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0289 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5544 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001060R0105 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |