View larger
1SDA073214R1 ABB E6.2H 4000 Ekip Touch LI 4p WMP
1SDA073214R1
073214
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E6.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 1SDA073214R1 ABB E6.2H 4000 Ekip Touch LI 4p WMP is an advanced air circuit breaker designed for high-current power distribution networks requiring precise electronic trip unit coordination. Such infrastructure components protect large industrial plants, commercial buildings, and utility substations against severe electrical anomalies. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2364
- Environmental Product Declaration - EPD: 9AKK108468A1905
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 77 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 920b2380-68dd-45a6-8670-cb5ae4b357ed China
- Simplified SCIP: 0900ae66-d000-45c0-a644-dfdf52ddb12f Belgium
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZDHWERAD000A000000XX
- EAN: 8015644770648
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2364 |
| Environmental Product Declaration - EPD | 9AKK108468A1905 |
| 9AKK108468A1913 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 77 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 920b2380-68dd-45a6-8670-cb5ae4b357ed China |
| Simplified SCIP | 0900ae66-d000-45c0-a644-dfdf52ddb12f Belgium |
| 226f2c7a-0197-479b-90ab-b351cebefb11 France | |
| 8d5bfb23-ebef-40d4-81fc-fe0495e1af8a Sweden | |
| 22dfef6f-7e66-4b0a-bae7-1690c31fa729 Poland | |
| c709e54f-48f3-4fbf-9e55-53f59a4ee5b8 Germany | |
| 1de5ec81-a75e-40f0-9d69-791b761b48d6 Portugal | |
| a7129016-0476-4d93-ab43-968e41326d4e Sweden | |
| d2c9e455-65e5-4502-abc4-4229ba064f92 Estonia | |
| 9ca66a94-b4f9-4086-9229-bef559c6aaf2 Poland | |
| dc396f6d-7737-4cb2-a902-bb400f375ada Hungary | |
| 3011409e-dfe8-421f-9923-335534c15367 Bulgaria | |
| 40b86542-214c-488b-bd11-7576c8dd75f6 Hungary | |
| 82d9a27f-9ce7-40da-9c5f-26e60c98965e Croatia | |
| 31ab4c73-c483-4b3d-8eca-412277df5eb3 Greece | |
| ebc165a7-7086-4fbd-bd02-75a9487d4d60 Denmark | |
| df75d278-16de-4f35-b571-224fd952afd3 Norway | |
| dc693dd3-11da-47bf-85a6-0ab1f472b2ad Spain | |
| a12c9a5e-b022-4875-883e-22d40ed4a0b4 Germany | |
| 1d31e714-9bf9-43d8-90b9-c40a0340b1eb Czech Republic | |
| b3c91e79-fd26-4368-b98b-b6aa1336374a Poland | |
| 2b04541c-95b9-41ae-aade-fa4ca278dc88 Netherlands | |
| e7d7005e-8e15-407c-a886-83dece4934a0 Belgium | |
| 9613ed7a-4ac3-43d4-824f-dd4cb7dab8e7 Finland | |
| af6acf38-a62f-4396-8ef8-0d68451175de Germany | |
| f9bbdf28-446d-41f1-94c3-999d9bf18bf7 Germany | |
| 5d8ffd11-1364-49ec-9774-df7f1038623b Germany | |
| 8592dbb5-4702-44d3-98c9-89f10fc357b0 France | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZDHWERAD000A000000XX |
| EAN | 8015644770648 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 929 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 134 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 1127 mm |
| Package Level 1 Gross Weight | 143 kg |
| Package Level 1 EAN | 8015644770648 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0289 |
| Technical | |
| Connecting Capacity | 4000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 4000 cycle |
| Ue = 500 ... 690 V 4000 cycle | |
| 10 cycles per hour | |
| Mechanical Durability | 12000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 50 % |
| Number of Poles | 4P |
| Power Loss | 544 W |
| Rated Current (In) | 4000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 kA |
| for 3 s 100 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (525 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Uninterrupted Current (Iu) | 4000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E6.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5544 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001060R0105 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |