View larger
1SDA071234R1
071234
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2364 |
| Environmental Product Declaration - EPD | 9AKK108468A1905 |
| 9AKK108468A1913 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 77 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 00f8a937-49c6-4a17-858b-320e5bcd6817 Italy |
| Simplified SCIP | 1fde24f9-6982-44ea-a0d8-f7c1bb72f41b Poland |
| fdd356be-73d0-403f-90d5-6a9960746049 Germany | |
| 7f5614a0-a9b9-4938-b065-f1cea4df136b Norway | |
| 557c7154-99d7-4076-9a41-f80aadf0596d Finland | |
| 8c27bf3e-1e6c-4ba7-91c8-9ca47f235bc8 Belgium | |
| 95e4a2e7-ec63-45ed-a3f2-c6faa9eb5d4e Germany | |
| 7fb08746-ed85-4629-8728-ccb1059bb97a Czech Republic | |
| 7143969d-8262-475e-a842-abb2c97b4fc0 Germany | |
| ae23e0e4-5643-40b0-9309-d0102cb596cf Denmark | |
| d8e514e9-e673-476b-9e14-9a24eeb384fa Poland | |
| dd850c19-f2b6-4156-af0f-893925e6fd68 Netherlands | |
| e488c5a2-2ef8-411e-9b84-738ec476a157 Hungary | |
| 0e3c85f9-a808-4590-9379-ee352a5ab5c9 Estonia | |
| f31ae9f7-e688-44e6-a032-caa7fbe08f1f Croatia | |
| 449f746f-f16c-4805-a824-735c301927af Greece | |
| 1232b329-dba2-4284-9279-7be659fb4fd1 Sweden | |
| 780806a5-d627-490d-894a-aecfd3234e0f Bulgaria | |
| f8f5ee9f-622b-4c66-ab6a-79affefa2dd8 Portugal | |
| 62573a94-bcf0-4f5f-8216-02f40fac8caf Poland | |
| 3dfd4fa8-6601-4332-9605-2b3132106a5e France | |
| 19b88a7f-5608-4c3d-9758-19a7ef46de68 Spain | |
| 69d57e38-017e-4a07-92cc-23a200515b8e Hungary | |
| 4ba42107-6d3d-465f-a5a2-7e1618906ce7 Sweden | |
| 35a0e066-8824-4fc3-84f3-705fc4f91c43 Germany | |
| 6ae0326d-6a2a-431e-a867-68d31b5ae60a France | |
| 9247c126-5d58-4c23-8761-df2f1b89a306 Germany | |
| 92274bd2-8ed6-4ea2-99f5-ef353376a700 Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z6HWERBD000A000000XX |
| EAN | 8015644750848 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 762 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 109 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 1000 mm |
| Package Level 1 Gross Weight | 118 kg |
| Package Level 1 EAN | 8015644750848 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0223 |
| Technical | |
| Connecting Capacity | 4000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 4000 cycle |
| Ue = 500 ... 690 V 4000 cycle | |
| 10 cycles per hour | |
| Mechanical Durability | 12000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 309 W |
| Rated Current (In) | 4000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 kA |
| for 3 s 100 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (525 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Uninterrupted Current (Iu) | 4000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E6.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5544 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001060R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 4000 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 100 kA |
| Overload release current setting (EF002336) | 1600.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 6000.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Back |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |