View larger
1SDA071856R1 ABB E4.2V 4000 Ekip Touch LSIG 4p F HR
1SDA071856R1
071856
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E4.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The 1SDA071856R1 ABB E4.2V 4000 Ekip Touch LSIG 4p F HR operates as a high-capacity air circuit breaker designed for critical power distribution systems and industrial switchgear. These units deliver precision electronic protection, effectively mitigating fault currents and ensuring uninterrupted power management across major facilities.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2363
- Environmental Product Declaration - EPD: 9AKK108468A1904
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.3 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 0226426e-4d0b-42da-9e6f-282106dd0b76 Italy
- Simplified SCIP: bf9c64ff-d6b3-4308-9da4-a169626d59b6 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZCVWERBF000A000000XX
- EAN: 8015644757069
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108468A1904 |
| 9AKK108468A1910 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.3 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 0226426e-4d0b-42da-9e6f-282106dd0b76 Italy |
| Simplified SCIP | bf9c64ff-d6b3-4308-9da4-a169626d59b6 Germany |
| ca801d55-6616-4987-addf-3569e15d5365 Poland | |
| d28176c0-f378-491d-a052-0bd2c5c68c68 Sweden | |
| 3f129954-20c9-4a45-bfe7-0f4a2521f367 Germany | |
| c48b8c62-2578-4968-84bf-7ac305ebe5ac Czech Republic | |
| 315e700e-7549-4a69-8d34-8149f325439f Croatia | |
| a51b06f4-40d0-4b71-a938-8eefb09d739c Belgium | |
| fe06fb64-1e9d-4a77-80b5-f822da0f8de9 Finland | |
| 8a87e212-b122-495b-bed9-77c129a88658 France | |
| 63669766-828a-45ed-bfe6-07f5a8fa8144 Poland | |
| 59ef38dd-f05e-43d0-80a7-4037f4d73901 Norway | |
| d060d81b-653e-467c-a00e-6a71d806fea6 Hungary | |
| 5b5fa984-7b63-441d-b40c-dc5cb388fcad Estonia | |
| 77c73926-313a-45fa-887f-e43a16df8464 Denmark | |
| 022046ed-8a82-4a3d-984d-09681036276b Greece | |
| f0ed3b53-344b-4175-9fc6-e25299bf69d6 Sweden | |
| c1f569f8-0d28-48d7-95be-636e2acbbda6 Germany | |
| daac185f-7c35-4bb1-9bff-c4545f6af736 Germany | |
| f8ef2554-6ca3-4133-9b0e-ee0d21704866 France | |
| 3137ee56-02c7-4e02-824f-ed8a3b87877e Poland | |
| 1685e5c9-4fad-4e13-82d0-7151b4572f76 Netherlands | |
| c907cf46-7918-418d-ac49-92b71b78d302 Belgium | |
| c335306c-bb22-4cf5-b259-b42bb9c81489 Germany | |
| 112ac110-3e6b-4d4d-b1ae-bca9eb7389e1 Hungary | |
| 2bc99649-9af9-4707-aefa-583587a5d475 Spain | |
| c6ae947f-73b4-4052-b698-d03ee0d454ca Portugal | |
| 1d180de9-f5a2-4449-851c-56d83071f3a0 Bulgaria | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZCVWERBF000A000000XX |
| EAN | 8015644757069 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 510 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 70 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644757069 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0197 |
| Technical | |
| Connecting Capacity | 4000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 5000 cycle |
| Ue = 500 ... 690 V 4000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 15000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 465 W |
| Rated Current (In) | 4000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 150 kA |
| (230 V AC) 150 kA | |
| (380 V AC) 150 kA | |
| (400 V AC) 150 kA | |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 kA |
| for 3 s 75 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 150 kA |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 100 kA | |
| (525 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Uninterrupted Current (Iu) | 4000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | V |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5545 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001001R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |