View larger
1SDA071855R1 ABB E4.2V 4000 Ekip Touch LSI 4p F HR
1SDA071855R1
071855
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E4.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Power distribution networks utilize the 1SDA071855R1 ABB E4.2V 4000 Ekip Touch LSI 4p F HR as a high-capacity air circuit breaker for comprehensive load management. These devices manage and interrupt high fault currents to ensure the safety and continuity of large commercial power installations.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2363
- Environmental Product Declaration - EPD: 9AKK108468A1904
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.3 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 5ef717b3-f7cc-42e7-8680-1cf3d1b1664e Italy
- Simplified SCIP: 3d828b6a-9392-4203-b66e-085cfce5c027 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZCVWERBE000A000000XX
- EAN: 8015644757052
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108468A1904 |
| 9AKK108468A1910 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.3 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 5ef717b3-f7cc-42e7-8680-1cf3d1b1664e Italy |
| Simplified SCIP | 3d828b6a-9392-4203-b66e-085cfce5c027 Germany |
| fa9ec37c-b990-4664-a4de-d22ec9e1ec69 Estonia | |
| 7dc6eab2-c582-4a60-9fa0-967b284fdfd2 Greece | |
| 93a98d65-ac1b-4222-802d-acefb9aa131d Portugal | |
| 4271e422-1a8d-493b-a6f1-30cc5733bf0e Bulgaria | |
| 26548a91-3365-4ee0-b761-56dce3c9e5c3 Poland | |
| 93f8f2ae-83ac-4369-9153-2f02c5e17416 Sweden | |
| c3cd69ba-1dc2-4c5a-9f73-fbbf5ec22196 Denmark | |
| c19b11e4-9e6c-43ff-a289-0f7aebcb3663 Croatia | |
| ac06da68-c5d0-4549-a113-b647a56215e8 Norway | |
| ea679fcd-7769-4ecb-8aa7-83c1fd2cfadb Poland | |
| 1cf285f5-a78a-40f2-910a-47cded83f653 France | |
| 37ef0521-94aa-475d-8159-a255130edbf5 Germany | |
| 9fd271dc-da53-438d-96c1-2264b99b679a Hungary | |
| 3a141d85-85e1-44a9-9ca3-25ad4440d779 Belgium | |
| e72bdf9f-8240-47e3-9202-327db520e0b2 France | |
| 34ae5140-15c7-41df-b84c-d69804783dfa Sweden | |
| fa86ef55-da66-42fd-a93d-a8978b70e868 Finland | |
| 7343911c-00f1-4caf-b927-a1f1ce056e8d Belgium | |
| 1cd4aa23-d9ae-4e95-b7dc-de9bf6b652c9 Czech Republic | |
| 466351d6-b7b6-43f7-aa6f-4a5266a90615 Germany | |
| 92f27b2a-78df-448f-8b16-5c5aff1301c2 Poland | |
| d3104140-4497-4574-b9b4-85ad602c3e15 Germany | |
| 71a3dab6-6f15-4a6c-945e-88771bcba924 Netherlands | |
| c46b2da0-d2aa-4d73-be84-54fd85b46bef Hungary | |
| c2917696-e84a-4cad-b5a3-1e95a56881ab Germany | |
| c15f585c-04d3-493c-a1c0-c8e527e99ba6 Spain | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZCVWERBE000A000000XX |
| EAN | 8015644757052 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 510 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 70 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644757052 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0197 |
| Technical | |
| Connecting Capacity | 4000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 5000 cycle |
| Ue = 500 ... 690 V 4000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 15000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 465 W |
| Rated Current (In) | 4000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 150 kA |
| (230 V AC) 150 kA | |
| (380 V AC) 150 kA | |
| (400 V AC) 150 kA | |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 kA |
| for 3 s 75 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 150 kA |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 100 kA | |
| (525 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Uninterrupted Current (Iu) | 4000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | V |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5545 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001001R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |