View larger
1SDA073208R1 ABB E4.2V 4000 Ekip Hi-Touch LSI 4p WMP
1SDA073208R1
073208
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E4.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Providing elite performance in high-capacity electrical systems, the 1SDA073208R1 ABB E4.2V 4000 Ekip Hi-Touch LSI 4p WMP functions as a drawout air circuit breaker engineered for major power distribution applications. Electrical engineers specify units of this caliber in heavy industrial environments to ensure reliable overload management and selective fault tripping. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2363
- Environmental Product Declaration - EPD: 9AKK108468A1904
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.3 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 166c3474-538e-49db-91f4-c899d83c8ff4 Italy
- Simplified SCIP: 6275e6eb-d925-443b-907e-855a528e4fa3 Belgium
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZCVWERAJ200A000000XX
- EAN: 8015644770587
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108468A1904 |
| 9AKK108468A1910 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.3 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 166c3474-538e-49db-91f4-c899d83c8ff4 Italy |
| Simplified SCIP | 6275e6eb-d925-443b-907e-855a528e4fa3 Belgium |
| 35ef973f-2cdf-42ee-8bb5-7c0a2244f457 Belgium | |
| be5c9e13-f86e-4110-a7f1-23e9dce1ca33 Germany | |
| 4e59e6d8-920c-41ea-83e1-ac675c466f4d Finland | |
| 840ca72f-7611-42b6-8160-c2b166a36ea4 Norway | |
| 0beb9a14-f822-4bf9-93de-5e02dd017aa4 Poland | |
| da06c034-65c4-4010-b35e-5ce93f19138d Germany | |
| 22f836e0-9d4a-447f-9f72-392103073338 Hungary | |
| 1e8d1893-d778-45cc-a97f-f2c10d5b2fb1 Croatia | |
| 149457ac-35f0-4a93-98bc-2610cd559f2a Estonia | |
| 89f03139-e70d-4a22-bc11-b9bea218af35 Sweden | |
| 02151437-b29f-4cc0-9bc4-d400411155c1 Bulgaria | |
| 577dce64-2868-4a1a-b9b7-ec032d8090f2 Greece | |
| 02ac8fed-bdbc-4319-a7af-a1deb815c2b0 Portugal | |
| b7b63947-bfd9-4a76-85a3-8d4361d8a211 Poland | |
| b7413db0-d6e5-456b-b178-9255f2b5d8b4 Czech Republic | |
| 2a04c7f7-845c-4507-9d18-04f45a82c872 Netherlands | |
| f10f759c-c947-4507-bb0f-59407405d26f Denmark | |
| 6f271a23-eaac-4d82-b000-5e4ca5d98bb6 Germany | |
| 8be3df38-cde9-45f4-b27a-1bf3406324c4 France | |
| d73e5627-e8e3-428d-a5c6-4293239f3f79 Poland | |
| ef1e8ffa-9f98-4005-b044-dca97c8e9be7 France | |
| b5852f4f-584d-4827-afd8-6ac814cac149 Hungary | |
| 1a27e5de-fd50-42f0-8b4b-f3c70db710e9 Spain | |
| b431a347-232b-49b3-bb86-4a56d0b4d695 Sweden | |
| 3e9d3851-fe0b-4d6b-9fa4-4214306ccfea Germany | |
| fc221d95-7dbd-4128-b3cc-c67e87c5ecc7 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZCVWERAJ200A000000XX |
| EAN | 8015644770587 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 551 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 74 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 81 kg |
| Package Level 1 EAN | 8015644770587 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0434 |
| Technical | |
| Connecting Capacity | 4000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 5000 cycle |
| Ue = 500 ... 690 V 4000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 15000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 900 W |
| Rated Current (In) | 4000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 150 kA |
| (230 V AC) 150 kA | |
| (380 V AC) 150 kA | |
| (400 V AC) 150 kA | |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 kA |
| for 3 s 75 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 150 kA |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 100 kA | |
| (525 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Uninterrupted Current (Iu) | 4000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | V |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5545 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001001R0102 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |