View larger
1SDA073153R1 ABB E4.2V 3200 Ekip Dip LSIG 4p WMP
1SDA073153R1
073153
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E4.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for large-scale power distribution systems, this ABB air circuit breaker offers sophisticated trip unit functionality to monitor and protect critical infrastructure against electrical faults. Its withdrawable design supports safe integration into complex electrical switchgear. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2363
- Environmental Product Declaration - EPD: 9AKK108468A1904
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.3 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: f67d0a5f-c718-4acd-976d-3ef6e275a4ba Italy
- Simplified SCIP: 72cf74bc-87c4-4b37-938e-513a3239d228 Belgium
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZCVVENAC000A000000XX
- EAN: 8015644770037
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108468A1904 |
| 9AKK108468A1910 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.3 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | f67d0a5f-c718-4acd-976d-3ef6e275a4ba Italy |
| Simplified SCIP | 72cf74bc-87c4-4b37-938e-513a3239d228 Belgium |
| 7d856703-b1bf-4018-8758-712f9328be46 Hungary | |
| c6758345-0b60-429e-95e2-30d211c7488a France | |
| 0da8d536-4661-4b45-9359-e0abdbf8a59e Spain | |
| 9575e772-7afa-4ff4-b24f-85ad135e9e5a Germany | |
| 00fd9186-899a-470d-81f4-5a034ecd91e0 Sweden | |
| 234a208e-0e3c-4f6c-990b-7f9088a5240d Germany | |
| eda14e17-d797-45f1-8cf7-f00fce2e68f4 Poland | |
| 0f15b567-0a35-409b-b54e-ba63cdb585ef Bulgaria | |
| 8e60fa4c-a926-4b85-8ff0-586a9e3cf263 Sweden | |
| cf0a7e88-cd2b-4d8b-9758-fcdbd32ef2e7 Portugal | |
| d748dc75-ed61-4950-a03d-96f9c26c3818 Greece | |
| 46ad2c91-522e-4fb4-a19e-0dac6dc0cf13 Estonia | |
| 2efd0bd5-3f47-41b4-a700-a28929cb0de4 Hungary | |
| da462808-af09-4372-98e5-270e3dade678 Netherlands | |
| f989544a-8cfd-4f3a-8fd7-1aca9b1e4997 Poland | |
| a69e305d-d512-4307-b903-fd4949ef1fee Czech Republic | |
| 8b6e3e2d-fac7-4de3-823d-74590bb84a10 Germany | |
| de018ca4-0613-4833-9f08-1df935f83f11 Croatia | |
| a293ca36-35b0-44be-882c-db4d6b6f7a30 France | |
| cb6dfb8a-2d60-49b3-accc-79eebf72f8e6 Poland | |
| 016d911c-217f-41ce-afa3-c00c5999acba Germany | |
| 25e8a314-9820-4f40-bc6a-a3528011b61c Norway | |
| b05a6f68-baf5-4605-8ab0-605a042d74d5 Finland | |
| 17b774e4-67eb-4aef-bc5d-8c10dc642525 Germany | |
| 50968e54-e9c2-475f-8f02-e18f0d3d2044 Denmark | |
| 8ebfc6b4-2669-4a6d-9c6e-67de8c920256 Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZCVVENAC000A000000XX |
| EAN | 8015644770037 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 551 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 74 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 81 kg |
| Package Level 1 EAN | 8015644770037 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0434 |
| Technical | |
| Connecting Capacity | 3000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 7000 cycle |
| Ue = 500 ... 690 V 7000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 743 W |
| Rated Current (In) | 3200 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 150 kA |
| (230 V AC) 150 kA | |
| (380 V AC) 150 kA | |
| (400 V AC) 150 kA | |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 kA |
| for 3 s 75 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 150 kA |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 100 kA | |
| (525 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Uninterrupted Current (Iu) | 3200 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | V |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5545 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001001R0102 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |