View larger
1SDA071736R1
071736
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108468A1904 |
| 9AKK108468A1910 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.3 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 8382151a-9625-432d-a25e-dbf52890baa8 Italy |
| Simplified SCIP | 9dbbf37c-fbb3-42da-8600-6a083d9cae45 Germany |
| 4f98980a-69d3-45c2-87da-6a58f2026bec Estonia | |
| 531de645-8816-464f-88d8-ea77ccc447dc Greece | |
| ddd1fa78-fedc-40b7-bf6e-f1ac27be065d Portugal | |
| 3d1892e9-4c7e-4f5b-aefa-0b06b7f755cd Sweden | |
| 77e42b8a-3cb6-4c93-8f04-5fcc7cfa859d Poland | |
| 197e318a-95bd-44b8-9236-a7dc9b1c3f8e Denmark | |
| 3efbd349-1430-4ab3-9ecc-9d2aa7b06c84 Bulgaria | |
| 2cbdc7be-a237-4a35-a704-1feeefc79dba Hungary | |
| 46cd7b36-ab57-47ea-8301-49d52a9e9cf3 Germany | |
| ee3ba4a4-f724-42bb-97a3-214b07ebc245 France | |
| a4d878d9-5a8b-4da0-8ee6-9f3e2d76a073 Poland | |
| 14ba73ef-b582-46ad-a6a5-a9d40b2dda66 Norway | |
| 6523570a-f44b-4de1-bb43-6be35751d584 Croatia | |
| 15001ae4-4da1-4aa9-a691-9e766e830b55 Germany | |
| 7134e90c-0281-4b55-84af-de98ca5655f7 Germany | |
| c40ec50d-4246-41ae-8218-09552cb15946 Germany | |
| bc79aa88-84c2-4839-8293-c795a0f96f98 Hungary | |
| 7b06d498-5367-4e40-801d-72f958e911cc Poland | |
| 931f7a91-5826-4cbc-ab4b-7a5ac3376965 France | |
| 1354555f-edcd-4cf4-96fc-97c9b5e537a6 Netherlands | |
| f0f5d82d-5504-4514-86c1-4be12acf74b8 Spain | |
| 442228d9-89a2-47d4-a4aa-2b6d650b7f87 Belgium | |
| 1fc4e5c4-81c2-48bf-be76-a9b83911b641 Finland | |
| ce42f407-7193-4f21-ab46-691d79656c32 Sweden | |
| b926a803-150e-4bdd-9b7a-df9edabf238d Czech Republic | |
| 075035d8-59e6-4017-acef-858c680f6a50 Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZCVTEKBF000A000000XX |
| EAN | 8015644755867 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 510 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 70 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644755867 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0197 |
| Technical | |
| Connecting Capacity | 1600 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 10000 cycle |
| Ue = 500 ... 690 V 10000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 425 W |
| Rated Current (In) | 2000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 150 kA |
| (230 V AC) 150 kA | |
| (380 V AC) 150 kA | |
| (400 V AC) 150 kA | |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 kA |
| for 3 s 75 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 150 kA |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 100 kA | |
| (525 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | V |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5545 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001001R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |