View larger
1SDA071739R1 ABB E4.2V 2000 Ekip Hi-Touch LSIG 4p F HR
1SDA071739R1
071739
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E4.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Equipped with sophisticated electronic release units, this ABB 1SDA071739R1 air circuit breaker controls and protects high-capacity electrical distribution systems. It is deployed in major commercial and industrial installations to ensure safe load switching and fault isolation.
Final pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2363
- Environmental Product Declaration - EPD: 9AKK108468A1904
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.3 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 60b498d7-6a07-4b26-8ab2-64d2f894cfb9 China
- Simplified SCIP: 1d0b4821-effc-4054-b489-a0dcf685dd88 Sweden
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZCVTEKBK200A000000XX
- EAN: 8015644755898
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108468A1904 |
| 9AKK108468A1910 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.3 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 60b498d7-6a07-4b26-8ab2-64d2f894cfb9 China |
| Simplified SCIP | 1d0b4821-effc-4054-b489-a0dcf685dd88 Sweden |
| 9c24df03-a8bc-49e3-af85-4a393fdf43fe Bulgaria | |
| 9bbe21d3-882f-4637-b301-0ee62e9ea5fe Estonia | |
| 2eb9efbb-6383-4e3d-8168-399aa4a04475 Hungary | |
| e8220988-4053-4f02-bf20-a36d23d46ba1 Poland | |
| 46d432aa-edb4-4bf3-b239-4dd3a9ee9434 Germany | |
| 8ee672f7-5147-43f5-9fe9-904e39591af1 Norway | |
| f58f7396-a391-43b8-8549-9a9a568aaeb4 Croatia | |
| b9cfefa3-4f90-4fa6-89bf-4e0387b13deb Denmark | |
| b2d1041d-a746-4c09-ba0a-74a5aea3088c Germany | |
| f8fb8d85-f3bc-41d9-9513-e6c9d181f9af Belgium | |
| 1bedd417-cdc5-4b7f-a0fb-d602c6ddd04a Hungary | |
| 04cf27e1-44d3-4f2a-8be4-7857bc52a26d Greece | |
| dc6ef5b2-96d2-4ce8-b63d-d1d00ecbe116 Poland | |
| c75f89d9-829b-49ea-9119-35201c7726e8 France | |
| 089154bb-0048-433c-8926-575538480fe8 Spain | |
| a51d3302-e9ac-44b1-949f-4483dcaf1c7b Portugal | |
| 64a63f47-7c1f-4e5b-8e5a-37ebbc94a097 Sweden | |
| ee669f9f-6840-4b49-8d37-6aebd74f0555 Czech Republic | |
| fabc1ccc-b4c1-4360-aa2a-11c53f5bd91a Germany | |
| 08a27efa-475a-47d5-9da2-d8c73511e061 Netherlands | |
| 38bc033a-b541-42ed-aaf4-3a53b7e911bd Poland | |
| 6bdf5361-42f2-402a-8c85-99ba0704d57f Belgium | |
| f3538bd7-a376-4f2e-b977-03882fea7674 Germany | |
| c6b0f51e-b202-4f1d-9c83-87cf17aedf7d France | |
| fcc3f439-fc5d-4769-b879-de90862e8850 Germany | |
| 26f17c49-4f03-4929-86aa-feab26e87e88 Finland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZCVTEKBK200A000000XX |
| EAN | 8015644755898 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 510 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 70 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644755898 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0197 |
| Technical | |
| Connecting Capacity | 1600 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 10000 cycle |
| Ue = 500 ... 690 V 10000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 425 W |
| Rated Current (In) | 2000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 150 kA |
| (230 V AC) 150 kA | |
| (380 V AC) 150 kA | |
| (400 V AC) 150 kA | |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 kA |
| for 3 s 75 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 150 kA |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 100 kA | |
| (525 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | V |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5545 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001001R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |