View larger
1SDA073081R1 ABB E4.2V 2000 Ekip Dip LI 4p WMP
1SDA073081R1
073081
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E4.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for high-capacity electrical systems, the 1SDA073081R1 ABB E4.2V 2000 Ekip Dip LI 4p WMP air circuit breaker protects primary distribution lines and heavy industrial assets. These robust units interrupt excessive fault currents to maintain operational safety and prevent catastrophic equipment failures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2363
- Environmental Product Declaration - EPD: 9AKK108468A1904
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.3 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 40e89cab-6ad1-42ea-81b5-0dd7c93fbcf9 China
- Simplified SCIP: ddb8f611-30ac-4cf8-bb29-9bc703956b0a France
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZCVTEKAA000A000000XX
- EAN: 8015644769314
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108468A1904 |
| 9AKK108468A1910 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.3 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 40e89cab-6ad1-42ea-81b5-0dd7c93fbcf9 China |
| Simplified SCIP | ddb8f611-30ac-4cf8-bb29-9bc703956b0a France |
| b9cd35ae-6ed4-4b93-ad42-8d991cd9471f Hungary | |
| 061a1cb4-dc7b-4156-b337-548d9a26d34e Poland | |
| 6e1078ea-43ec-4bf4-acf7-5bc1a4a1773c Bulgaria | |
| 2a84f040-16b8-4c06-9300-d9f7eb4fc583 Estonia | |
| 41b43967-5d47-4591-90f1-92f869990042 Portugal | |
| 06fd842a-d201-4182-9d33-93e1fd643c99 Germany | |
| 62a9eec1-f543-41ac-ad0e-2bd416a6d5d3 Sweden | |
| dc48ac67-d3c5-4454-9fa7-8c982ecff5f8 Belgium | |
| 59f6f935-a912-4957-9f6a-29d09892d570 Poland | |
| 0beee165-2d93-4876-b94b-2a79cee51122 Hungary | |
| 01511996-80eb-4a39-9caa-41ecfa8c6069 Croatia | |
| a0ba6f0b-a0ea-421f-8e4b-d99f95328035 Greece | |
| 0695ceed-0ecc-40b9-9b9d-01d2ad999d58 Denmark | |
| 7493b525-d424-426b-8f9d-b8995c8f01da Germany | |
| a22cc6b6-9e1e-4afa-a4b9-ef597590050a Norway | |
| 3526f6bf-4e61-4336-aa84-9839e71f445a Sweden | |
| 8c43d72e-cffd-49ee-9330-21a6ce2acfb8 Spain | |
| 71512b5b-1939-49b8-bf9b-97e43f9d1df1 Germany | |
| 4840d704-b013-43e8-ba16-eeebb7b71fca France | |
| d6f3cd09-2057-4f3f-9229-0fbd428badc8 Belgium | |
| c7d3e2fd-ce0f-4e19-b351-32de7c7ecb66 Germany | |
| c55e6462-a7b9-4475-aee5-d6ed15767388 Finland | |
| f23b44d4-c4a5-453c-bdc8-9e3ad6695488 Netherlands | |
| 530047b5-30b8-434f-b457-9765206302e5 Poland | |
| 14af1d8b-848d-449c-bd28-942332fa677a Czech Republic | |
| c91c09eb-05ef-45ce-b0cc-fd1503628ac2 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZCVTEKAA000A000000XX |
| EAN | 8015644769314 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 551 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 74 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 81 kg |
| Package Level 1 EAN | 8015644769314 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0434 |
| Technical | |
| Connecting Capacity | 1600 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 10000 cycle |
| Ue = 500 ... 690 V 10000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 743 W |
| Rated Current (In) | 2000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 150 kA |
| (230 V AC) 150 kA | |
| (380 V AC) 150 kA | |
| (400 V AC) 150 kA | |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 100 kA |
| for 3 s 75 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 150 kA |
| (415 V AC) 150 kA | |
| (440 V AC) 150 kA | |
| (500 V AC) 100 kA | |
| (525 V AC) 100 kA | |
| (690 V AC) 100 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | V |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5545 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001001R0102 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |