View larger
1SDA073133R1 ABB E4.2S 3200 Ekip Dip LSIG 4p WMP
1SDA073133R1
073133
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E4.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Providing dependable heavy-duty circuit protection, the 1SDA073133R1 ABB E4.2S 3200 Ekip Dip LSIG 4p WMP is an advanced air circuit breaker deployed in major electrical distribution networks. These units manage high current loads, offer precise trip characteristics, and ensure operational safety across complex industrial facilities.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2363
- Environmental Product Declaration - EPD: 9AKK108468A1904
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.3 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
- Simplified SCIP: 4f00568f-d493-4060-be8a-e0bf9cc0eb74 France
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZCSVENAC000A000000XX
- EAN: 8015644769833
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108468A1904 |
| 9AKK108468A1910 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.3 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy |
| Simplified SCIP | 4f00568f-d493-4060-be8a-e0bf9cc0eb74 France |
| 002a23c7-72dc-4235-8de8-f64eb6b77de9 Greece | |
| 9eef27cf-9717-48a9-a45a-02bd65a98eb2 Sweden | |
| a64f46e3-a2da-426f-91da-066e169475e6 Estonia | |
| 8ba744fb-5781-4f60-abc5-6b3d9499f013 Portugal | |
| a1a1af88-781e-476a-9bc7-885a630299af France | |
| a5ae8c3d-1848-4cb5-b9fa-5462ed246213 Poland | |
| 62ff3695-9cb2-477e-a619-b81042d81e67 Germany | |
| a8f0d6a1-fb33-42fc-b1db-f8d97d67fb7a Germany | |
| 4dffced0-7cac-4685-8030-e82f095137f1 Sweden | |
| 418fbbfa-d9d0-4f5b-b4c9-52593f7d43a8 Bulgaria | |
| 59e81fdc-0983-4ffc-b018-dec5c3079c79 Netherlands | |
| fef3b6d2-48b8-468b-b14a-2d25c56f3c0b Finland | |
| 6167b100-4e8d-43ec-bb94-152b81e4c0ed Croatia | |
| a63ab89b-b478-4f27-b6b0-5cc3729f4477 Germany | |
| e2dd18f7-7f07-4326-9f86-b5f523091785 Czech Republic | |
| 4e86796f-e7d1-4be4-907c-c03d623a51a2 Belgium | |
| 8bbe218b-3af7-4d3f-a7a0-dc064a6ed4d3 Hungary | |
| 1c5198ea-0f6b-43e7-a052-501a750bd050 Poland | |
| fa05edd0-56e6-48c9-997c-2b1206fe7573 Hungary | |
| 0c95df99-b5fa-4c8d-96bc-9d68b971867f Spain | |
| b36ca2c8-cd2a-40f9-a4ed-0b0600033f38 Denmark | |
| 31378b6b-339a-4902-bc13-e0bf88a3bf8f Germany | |
| e6159394-40ac-4bdd-8d2e-740ddbd6eda8 Norway | |
| 0f2f5788-850a-49f2-a974-1dceba727e39 Belgium | |
| 6decd237-1e34-46ac-b543-75184ee31084 Germany | |
| 2aa39dc7-04c4-4d41-9f9a-b6cd1a582903 Poland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZCSVENAC000A000000XX |
| EAN | 8015644769833 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 551 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 74 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 81 kg |
| Package Level 1 EAN | 8015644769833 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0434 |
| Technical | |
| Connecting Capacity | 3000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 7000 cycle |
| Ue = 500 ... 690 V 7000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 743 W |
| Rated Current (In) | 3200 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 85 kA |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 3200 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5545 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001001R0102 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |